Automatic Pipetting Workstation LAPWS-A10 supports a pipetting range of 0.5 to 1000 µL, making it ideal for various laboratory tasks. It features efficient 384-well pipetting cycles, enhancing productivity and throughput in liquid handling processes. The workstation supports a variety of plates, including PCR, enzyme, and cell culture plates. Its compact and space-saving design ensures easy integration into any laboratory setting. Our automatic pipetting workstation is a reliable choice for efficient pipetting operations in laboratories.
Request Quote
Plate 3 to 6 plates
Pipetting Range 96 / 384 Channels
Pipetting Technique Air displacement
Core Index 1 Range: 0.5 to 10 µL
Accuracy: 1 µL ± 8%; 10 µL ± 2%
CV: 1 µL ≤ 6%; 10 µL ≤ 1.5%
Core Index 2 Range: 3 to 50 µL
Accuracy: 5 µL ± 4%; 50 µL ± 1.5%
CV: 5 µL ≤ 5%; 50 µL ≤ 1%
Core Index 3 Range: 3 to 300 µL
Accuracy: 10 µL ± 4%; 200 µL ± 0.8%
CV: 10 µL ≤ 6%; 200 µL ≤ 0.5%
Core Index 4 Range: 10 to 1000 µL
Accuracy: 10 µL ± 6%; 500 µL ± 0.5%
CV: 10 µL ≤ 5%; 500 µL ≤ 0.4%
Working Environment 5 to 40℃, 10 to 90% relative humidity, non-condensing
Power requirement Input voltage: 100 to 240vac ± 10%, frequency: 50/60hz ± 5%; output: 24V
Power 180 W
Dimension 750 × 250 × 460 mm
  • Efficient 384-well pipetting cycles
  • Compact and space-saving design
  • Supports PCR, enzyme and cell culture plates
  • High throughput capability
  • Consistent height adjustment
Automatic Pipetting Workstation LAPWS-A10 is used for high-throughput liquid handling. It is widely used in pharmaceutical companies, biotechnology research labs, clinical diagnostic centres and academic institutions.

Models of Pipetting Workstation

Labtron Pipetting Workstation range include automatic, semi-automatic, and manual models. These workstations cover volume ranges from 0.5 to 1000 µL, supporting applications across PCR, enzyme, and cell culture plates. Their compact, space-saving designs, make them easy to integrate into any lab setting. They employ advanced air displacement technology in both automatic and manual models, minimizing cross-contamination. Our pipetting workstations are reliable choices for precise and efficient pipetting operations in laboratories.

Automatic Pipetting Workstation LAPWS-A20

Automatic Pipetting Workstation LAPWS-A20

  • Plate : 6 plates
  • Pipetting Range : 8 Channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 10 µLAccuracy: 1 µL ± 8%; 10 µL ± 2%CV: 1 µL ≤ 6%; 10 µL ≤ 1.5%
Automatic Pipetting Workstation LAPWS-A22

Automatic Pipetting Workstation LAPWS-A22

  • Plate : 12 + 4 plates, additional 18-well reagent tube racks
  • Pipetting Range : 8 + 8 / 96 Channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 10 µLAccuracy: 1 µL ± 8%; 10 µL ± 2%CV: 1 µL ≤ 6%; 10 µL ≤ 1.5%
Automatic Pipetting Workstation LAPWS-A30

Automatic Pipetting Workstation LAPWS-A30

  • Pipetting Range : 4/8 channels
  • Pipetting Technique : Air displacement
  • Range : 0.5 to 1000 µL
  • Precision : ≤ 5%(200 µL)
Automatic Pipetting Workstation LAPWS-A31
Automatic Pipetting Workstation LAPWS-A31
  • Pipetting Range : 8 channels
  • Pipetting Technique : Air displacement
  • Range : 1 to 1000 L
  • Precision : ≤ 5% (200 µL)
Semi-Automatic Pipetting Workstation LSPWS-A10
Semi-Automatic Pipetting Workstation LSPWS-A10
  • Plate : 2 to 3 plates
  • Pipetting Range : 96 channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 10 µLAccuracy: 1 µL ± 8%; 10 µL ± 2%CV: 1 µL ≤ 6%; 10 µL ≤ 1.5%
Automatic Pipetting Workstation LAPWS-A21

Automatic Pipetting Workstation LAPWS-A21

  • Plate : 12 + 4 plates, additional 18-well reagent tube racks
  • Pipetting Range : 8 + 8 / 96 Channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 10 µL
Manual Pipetting Workstation LMPWS-A10

Manual Pipetting Workstation LMPWS-A10

  • Plate : 4 plates
  • Pipetting Range : 96 channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 20 µLAccuracy: 1 µL ± 8%; 10 µL ± 4%CV: 1 µL ≤ 6%; 10 µL ≤ 2%
Automatic Pipetting Workstation LAPWS-A11

Automatic Pipetting Workstation LAPWS-A11

  • Plate : 6 to 10 plates
  • Pipetting Range : 96 / 384 Channels
  • Pipetting Technique : Air displacement
  • Core Index 1 : Range: 0.5 to 10 µLAccuracy: 1 µL ± 8%; 10 µL ± 2%CV: 1 µL ≤ 6%; 10 µL ≤ 1.5%

Pipetting Workstation:
Automatic Pipetting Workstation LAPWS-A20, Automatic Pipetting Workstation LAPWS-A22, Automatic Pipetting Workstation LAPWS-A30, Automatic Pipetting Workstation LAPWS-A31, Semi-Automatic Pipetting Workstation LSPWS-A10, Automatic Pipetting Workstation LAPWS-A21, Manual Pipetting Workstation LMPWS-A10, Automatic Pipetting Workstation LAPWS-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.