Labtron Portable Airborne Particle Counters are designed for precise air quality monitoring in various environments. Each model features different flow rates, particle size ranges, and operational requirements. They utilize advanced laser technology and microcomputers to guarantee precise airborne particle counting and detection. We provide both manual and automatic counting modes, thermal printers with data conversion, and large data store capacities. Our Portable Particle Counters offer efficiency, dependability, and flexibility for continuous monitoring.
Flow Rate : 0.1 CFM ( 2.83 L/min )
Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Class : Class 100 to Class 300,000
Test Period : 1 min to 10 min ( 10 levels )
Flow Rate : 0.1 CFM ( 2.83 L/min )
Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Class : Class 100 to Class 300,000
Test Period : 1 min to 10 min ( 10 levels )
Flow Rate : 0.1 CFM ( 2.83 L/min )
Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Class : Class 100 to Class 300,000
Test Period : 1 min to 10 min ( 10 levels )
Flow Rate : 2.83 L/min
Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Alarm Level : Class100 to Class300,000
Test Period : 1 second to 99 minutes
Flow Rate : 28.3 L/min
Particle Size Channel : 0.1 µm, 0.2 µm, 0.3 µm, 0.5 µm, 1.0 µm, 5.0 µm
Test Way : UCL
Test Period : 1 to 40 min
Flow Rate : 1.0 CFM ( 2.83 L/min )
Particle Size Channel : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
Sensitivity : 0.3 µm
Flow Rate : 50 L/min
Particle Size Channel : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
Sensitivity : 0.3 µm
Flow Rate : 100 L/min
Particle Size Channel : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
Sensitivity : 0.3 µm
The majority of portable airborne particle monitors are unable to distinguish between various particle kinds. They take measurements of every particle in the air, including its concentration and size distribution. To identify particular particle kinds, however, further analysis methods might be required in some circumstances.
The manufacturers recommended calibration intervals for portable airborne particle monitors should be followed, usually every six to twelve months. Regulations and the particular application, however, may have an impact on the frequency of calibration.
It's true that some portable counters work well outside and offer useful data on particulate matter (PM) concentrations in surrounding air. They are employed in research projects about outdoor air quality, pollution control initiatives, and environmental monitoring investigations.
The detection range of Labtron counters varies according to the model and installation selected, but in general, they can detect particles as small as 0.3 microns and as large as up to 10 microns.
Yes, the functioning of these counters is made simple by their simple layout. Because they include options for both automatic and manual modes, they can be used by a variety of users in a variety of settings.
Post your question?
Our experts are here to help!
Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608