Request A Quote
Portable Airborne Particle Counter LPPC-A30

Portable Airborne Particle Counter LPPC-A30

Portable Airborne Particle Counter LPPC-A30 offers a flow rate of 28.3 L/min. Equipped with six channels that simultaneously assess various particle sizes. Employs laser technology for accurate detection and counting of airborne particles, ensuring precise size measurement. It calculates the upper confidence limit to estimate the maximum particle concentration crucial for quality control. Stores 256 sample data for future use.

Portable Airborne Particle Counter LPPC-A30
Portable Airborne Particle Counter LPPC-A30
Portable Airborne Particle Counter LPPC-A30
Request Quote
Flow Rate 28.3 L/min
Particle Size Channel 0.5µm, 1.0µm, 2.0µm, 3.0µm, 5.0µm, 10µm
Sampling period 1s to 99 mins 99s
Sampling frequence 1 to 99s
Maximum sampling Concentration 35000/L
Self cleaning time Less than 10 minutes
Continuously Working Time 8 h
Light Source and Lifetime Long life laser diode with 50,000 Hours MTTF
Display LCD
Data Storage 13,000/USB
Power consumption 80 W
Power AC 220 V+/-10%, 50 Hz
Dimension (W × D × H) 285 × 240 × 240 mm
Weight 7.35 Kg
  • Large LCD screen displays
  • Features Computerized verification
  • Built-in thermal printer
  • Data conversion between ft³ and m³

Portable Airborne Particle Counter is used in industries like pharmaceuticals, electronics, manufacturing, and healthcare to monitor and ensure cleanroom cleanliness by measuring airborne particles.

Models of Portable Airborne Particle Counters

Labtron Portable Airborne Particle Counters are designed for precise air quality monitoring in various environments. Each model features different flow rates, particle size ranges, and operational requirements. They utilize advanced laser technology and microcomputers to guarantee precise airborne particle counting and detection. We provide both manual and automatic counting modes, thermal printers with data conversion, and large data store capacities. Our Portable Particle Counters offer efficiency, dependability, and flexibility for continuous monitoring.

Portable Airborne Particle Counter LPPC-A11

Portable Airborne Particle Counter LPPC-A11

  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Class : Class 100 to Class 300,000
  • Test Period : 1 min to 10 min ( 10 levels )
Portable Airborne Particle Counter LPPC-B11

Portable Airborne Particle Counter LPPC-B11

  • Flow Rate : 50 L/min
  • Particle Size Channel : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
  • Sensitivity : 0.3 µm
Portable Airborne Particle Counter LPPC-A10

Portable Airborne Particle Counter LPPC-A10

  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Class : Class 100 to Class 300,000
  • Test Period : 1 min to 10 min ( 10 levels )
Portable Airborne Particle Counter LPPC-A20
Portable Airborne Particle Counter LPPC-A20
  • Flow Rate : 0.1 CFM ( 2.83 L/min )
  • Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Class : Class 100 to Class 300,000
  • Test Period : 1 min to 10 min ( 10 levels )
Portable Airborne Particle Counter LPPC-B10
Portable Airborne Particle Counter LPPC-B10
  • Flow Rate : 1.0 CFM ( 28.3 L/min )
  • Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
  • Sensitivity : 0.3 µm
Portable Airborne Particle Counter LPPC-B12

Portable Airborne Particle Counter LPPC-B12

  • Flow Rate : 100 L/min
  • Particle Size Channel : 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Test Period : 1 sec to 5999 sec ( 5 L to 3000 L )
  • Sensitivity : 0.3 µm
Portable Airborne Particle Counter LPPC-A21

Portable Airborne Particle Counter LPPC-A21

  • Flow Rate : 2.83 L/min
  • Particle Size Channel : 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm
  • Alarm Level : Class100 to Class300,000
  • Test Period : 1 second to 99 minutes
Portable Airborne Particle Counter LPPC-A30 FAQ's
  • To measure atmospheric particle concentrations more quickly and efficiently, our LPPC-A30 has a higher flow rate of 28.3 L/min. When analyzing an excessive amount of air quickly and accurately is necessary to ensure prompt results, this higher flow rate is especially helpful.

  • Its mean time to failure (MTTF) is 3000 hours. Our LPPC-A30 uses a long-life laser diode. In addition to lowering the need for routine maintenance and guaranteeing continuous use in crucial monitoring applications, this guarantees dependable and consistent performance over an extended length of time.

  • To start the measurement procedure with the least amount of delay possible, our LPPC-A30 has a zero count time of less than or equal to 10 minutes. Besides, it comes with an 8-hour continuous working time, which means that long tracking operations may be conducted without numerous pauses or recharging necessary.

  • The majority of portable airborne particle monitors are unable to distinguish between various particle kinds. They take measurements of every particle in the air, including its concentration and size distribution. To identify particular particle kinds, however, further analysis methods might be required in some circumstances.

  • The manufacturers recommended calibration intervals for portable airborne particle monitors should be followed, usually every six to twelve months. Regulations and the particular application, however, may have an impact on the frequency of calibration.

  • It's true that some portable counters work well outside and offer useful data on particulate matter (PM) concentrations in surrounding air. They are employed in research projects about outdoor air quality, pollution control initiatives, and environmental monitoring investigations.

  • The detection range of Labtron counters varies according to the model and installation selected, but in general, they can detect particles as small as 0.3 microns and as large as up to 10 microns.

  • Yes, the functioning of these counters is made simple by their simple layout. Because they include options for both automatic and manual modes, they can be used by a variety of users in a variety of settings.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.