Request A Quote
Portable Autoclave LPOA-C10

Portable Autoclave LPOA-C10

Portable Autoclave LPOA-C10 has an 18 L capacity and delivers efficient and reliable sterilization performance for clinical environments. Its precision pressure monitoring ensures accurate and safe operation. The efficient thermal control system maintains consistent temperatures for decontamination. Its seamless seal expansion design guarantees an airtight closure. Our portable autoclave has a corrosion-resistant body for durability and longevity.

Request Quote
Capacity 18 L
Working Sterilization Temperature 126℃
Working Sterilization Pressure 0.142 Mpa
Design Pressure 0.165 Mpa
Design Temperature 129℃
Voltage 220 V
Power Consumption 2 Kw
Sterilization Room Dimensions Ø280 × 235 mm
Packing Dimension (L × W × H) 40.5 × 40.5 × 43 cm
Gross Weight 12.5 kg
Net Weight 14.2 kg
  • Overpressure Self-Discharge System

  • High Temperature Tolerance

  • Dual Scale Pressure Gauge

  • Self-Expanding Seal Technology

  • Durable Stainless Steel Build

Portable Autoclave LPOA-C10 is a lightweight, mobile sterilization device that uses steam under pressure to disinfect medical and laboratory equipment. It is ideal for use in fieldwork, small clinics, and remote locations for convenient and effective sterilization.

Accessories Name

Quantity

Dual Scale Pressure Gauge

1

Self-Expanding Sealing Ring

1

Anti-dry Heater

1

Automatic Temperature Control Safety Valve

1

Models of Portable autoclave

Labtron Portable Autoclave provides efficient sterilization at temperature of 126℃ in compact environment. They are designed for easy transportation. Their user-friendly controls and minimal setup simplify the disinfection process and ensure ease of use. They are equipped with safety mechanism to prevent accidents. Our Autoclave is convenient solution in small research facilities, veterinary practices, field clinics and rural healthcare.

Portable Autoclave LPOA-B18

Portable Autoclave LPOA-B18

  • Capacity : 24 L
  • Working Temperature : 50 °C to 126 °C
  • Working pressure : 0.142 MPa
  • Working environment : 5 °C to 45 °C
Portable Autoclave LPOA-A17

Portable Autoclave LPOA-A17

  • Volume Of Chamber : 24 L
  • Working Temperature : 126 ℃
  • Working Pressure : 0.14 to 0.16 MPa
  • Max Safety Pressure : 0.165 MPa
Portable Autoclave LPOA-C12

Portable Autoclave LPOA-C12

  • Capacity : 18 L
  • Material Stainless Steel : 2.0 mm
  • Working Sterilization Temperature : 126℃
  • Working Sterilization Pressure : 0.142 Mpa
Portable Autoclave LPOA-A15
Portable Autoclave LPOA-A15
  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Timer range : 0 ~ 60 min
Portable Autoclave LPOA-B19
Portable Autoclave LPOA-B19
  • Capacity : 30 L
  • Working Temperature : 50 °C to 126 °C
  • Working pressure : 0.142 MPa
  • Working environment : 5 °C to 45 °C
Portable Autoclave LPOA-A13

Portable Autoclave LPOA-A13

  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Working pressure : 0.14 ~ 0.16 MPa
Portable Autoclave LPOA-B14

Portable Autoclave LPOA-B14

  • Volume of Chamber : 24 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically heated
  • Timer range : 0 ~ 60 mins
Portable Autoclave LPOA-B11

Portable Autoclave LPOA-B11

  • Volume of Chamber : 18 L
  • Working temperature : 126 ℃
  • Heating mode : Electrically / LPG heated
  • Working pressure : 0.14 ~ 0.16 MPa
Portable Autoclave LPOA-C10 FAQ's
  • Labtron portable autoclaves are specifically designed for applications where mobility, compactness, and efficiency are paramount. These units are ideal for small medical clinics, dental practices, veterinary settings, mobile labs, and on-field medical camps, especially in rural or emergency areas where a traditional autoclave setup isn’t feasible. Their lightweight and compact structure ensures they can be easily carried, stored, and set up without requiring complex infrastructure. Despite their size, Labtron ensures these autoclaves maintain consistent steam pressure and temperature for effective sterilization. This makes them reliable for sterilizing essential items like forceps, syringes, scissors, and glass containers during medical interventions or scientific testing on-site.

  • Labtron portable autoclaves are capable of sterilizing a broad range of heat-resistant medical and laboratory items, including surgical instruments, glassware, metal tools, cotton swabs, gauze, and certain types of rubber and plastic equipment. These autoclaves utilize saturated steam under pressure typically at 121°C and 15 psi to effectively eliminate all microbial life, including bacteria, viruses, fungi, and spores. However, they are not suitable for sealed containers, flammable liquids, or sensitive electronics, which could be damaged under pressure and high heat. Labtron includes user manuals with clear loading instructions and material compatibility charts to help users avoid damage and ensure the most effective sterilization process.

  • Labtron offers both electrically powered and non-electric models, such as kerosene, LPG, or spirit-heated units, to cater to a variety of environments. For laboratories and clinics with regular electricity, the electric models are plug-and-play, offering automated cycles and precise control. In contrast, for remote areas, mobile medical teams, or disaster response units, the non-electric variants offer complete independence from the power grid. These are particularly useful in developing regions or emergency situations, where reliable sterilization is needed despite lack of infrastructure. Labtron designs both models with easy-to-use heating systems, robust chambers, and durable materials to withstand repeated transportation and usage.

  • Labtron ensures that even its portable autoclaves include reliable pressure gauges and temperature indicators. These allow users to keep a real-time check on internal conditions and ensure the sterilization temperature (typically 121°C) and pressure (around 15 psi) are achieved and maintained for the required duration generally 15 to 30 minutes, depending on the load. Some advanced models may include alarm features that indicate when sterilization is complete or if unsafe pressure levels are approached. All units are fitted with safety release valves that automatically expel excess steam, preventing accidents. This user-friendly interface allows healthcare workers and lab technicians to confidently operate the autoclave, even with minimal technical training.

  • Labtron emphasizes regular maintenance to ensure optimal performance and safety. After every use, users should drain the chamber, remove residual water, and wipe down the interior to prevent rust or scale deposits. Weekly maintenance should include checking the gasket, pressure valve, and safety mechanisms for wear and tear. The heating element or burner depending on whether it's electric or fuel-based should be cleaned and tested monthly. Labtron provides detailed maintenance instructions, troubleshooting tips, and access to service support when needed. With proper care, Labtron portable autoclaves can provide years of reliable service in demanding environments.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.