| Capacity | 24 L |
| Material Stainless Steel | 2.0 mm |
| Working Sterilization Temperature | 126℃ |
| Working Sterilization Pressure | 0.142 Mpa |
| Design Pressure | 0.17 Mpa |
| Design Temperature | 129℃ |
| Voltage | 220 V |
| Power Consumption | 2 Kw |
| Sterilization Room Dimensions | Ø260 × 380 mm |
| Packing Dimension (L × W × H) | 39 × 39 × 77 cm |
| Gross Weight | 14 kg |
| Net Weight | 16 kg |
Thermal Insulation Layered Design
Leak-Proof Seal Mechanism
Smooth Operational Flow
High Load Endurance
Quick Startup Functionality
Portable Autoclave LPOA-C13 is a lightweight, mobile sterilization device that uses steam under pressure to disinfect medical and laboratory equipment. It is ideal for use in fieldwork, small clinics, and remote locations for convenient and effective sterilization.
Accessories Name | Quantity |
Dual Scale Pressure Gauge | 1 |
Self-Expanding Sealing Ring | 1 |
Anti-dry Heater | 1 |
Automatic Temperature Control Safety Valve | 1 |
Download catalog for
Portable Autoclave LPOA-C13 Catalog
Labtron Portable Autoclave provides efficient sterilization at temperature of 126℃ in compact environment. They are designed for easy transportation. Their user-friendly controls and minimal setup simplify the disinfection process and ensure ease of use. They are equipped with safety mechanism to prevent accidents. Our Autoclave is convenient solution in small research facilities, veterinary practices, field clinics and rural healthcare.
.webp)



.webp)



Labtron portable autoclaves generally complete a full sterilization cycle within 25 to 40 minutes, including heat-up, sterilization hold time (typically 15–20 minutes), and cooldown. However, this duration may vary depending on factors such as load volume, starting water temperature, type of load (solid vs. liquid), and environmental temperature. Heavy loads or densely packed instruments may require a few extra minutes to allow complete steam penetration. Labtron provides clear instructions for cycle optimization, including recommended load sizes and spacing tips to ensure that steam can circulate freely around each item, promoting efficient microbial kill rates without compromising energy use.
Labtron designs its portable autoclaves with smooth, crevice-free stainless steel chambers and easily cleanable surfaces that prevent the accumulation of biological debris or contaminants. To further reduce the risk of cross-contamination, Labtron advises users to thoroughly clean and dry the chamber between cycles, especially when switching between different types of loads (e.g., surgical tools and culture media). Autoclaves can also be fitted with optional removable baskets or trays, which are autoclavable themselves and aid in load separation. In high-contamination-risk environments, Labtron suggests running pre-sterilization rinse cycles or using autoclave-safe sterilization pouches to isolate instruments.
Labtron portable autoclaves are meticulously engineered with an internal design that promotes uniform steam circulation throughout the chamber. The structure includes strategically placed perforated trays, wire baskets, and venting channels that allow saturated steam to reach every surface of the load. This ensures that even instruments stacked or placed in containers receive consistent heat exposure. Labtron emphasizes the importance of not overcrowding the chamber and advises users to maintain appropriate spacing between instruments. The chamber is also slightly rounded to prevent cold spots and aid in natural convection. This efficient heat and moisture distribution is critical in achieving a consistent sterilization cycle that destroys all viable microbes, including heat-resistant bacterial spores.
Labtron prioritizes operator safety by incorporating a multi-level mechanical safety system in its portable autoclaves. These systems include a pressure interlock mechanism that physically prevents the lid from being opened until the internal pressure drops to a safe level, typically below 0.2 bar. In addition to this, a spring-loaded pressure relief valve is fitted to automatically vent excess pressure if it exceeds operational limits, ensuring no over-pressurization occurs. The sealing ring or gasket is designed to withstand high-temperature steam without slipping or deforming. Labtron’s robust construction also includes heat-insulated handles and locking clamps for manual models, giving users complete control and peace of mind during operation.
Labtron advises a regular preventive maintenance routine to ensure its portable autoclaves function optimally for years. Users should clean the chamber weekly using a soft, lint-free cloth and non-abrasive disinfectant. Monthly inspections of the rubber gasket are essential to check for cracks or warping that could affect pressure sealing. The heating element should be descaled quarterly using approved descaling agents, especially if the autoclave operates in hard water areas. Labtron also recommends checking the safety valve and pressure gauge calibration annually, which can be done using test kits or by authorized technicians. For busy labs or clinics, Labtron offers optional service contracts and calibration tools to ensure uninterrupted performance and compliance with sterilization protocols.