Request A Quote
Pulse Vacuum Autoclave LBPA-A10

Pulse Vacuum Autoclave LBPA-A10

Pulse Vacuum Autoclave LBPA-A10 has a volume of 250 litres and a maximum working temperature of 139℃. 304 stainless steel sanitary pipes with clamp joints and specifically made pneumatic valves are part of its piping system. The autoclave control system incorporates a PLC and a touchscreen HMI for precise real-time control and alarms. It features a strong rectangular chamber with reinforced jacket and interlocking pneumatic doors. Our autoclave is suitable for medical devices, dressings, implants, and liquids.

Pulse Vacuum Autoclave LBPA-A10
Pulse Vacuum Autoclave LBPA-A10
Pulse Vacuum Autoclave LBPA-A10
Pulse Vacuum Autoclave LBPA-A10
Request Quote
Volume 250 L
Maximum Working Temperature 139℃
Sterilization Temperature Precision 0 to 2℃
Temperature Uniformity ± 1℃
Design Temperature 150℃
Maximum Working Pressure 0.25 MPa
Ultimate Vacuum - 97 kPa
Vacuum Leakage Rate Up to 0.13 kPa/min
Negative Pressure Pulsation Amplitude - 80 to 0 kPa
Negative Pressure Pulsation Times 1 to 99
Times of Positive Pressure Pulses 1 to 3
Times of Pulses Across Pressure Amplitude: -80 to 80 kPa, Times: 1
Steam Consumption 18 kg/C
Tap Water Consumption 120 kg/C
Designed Pressure of Inner Chamber - 0.1 to 0.3 MPa
Designed Pressure of Jacket 0.3 MPa
Safety Valve Opening Pressure (Chamber) 0.28 MPa
Safety Valve Opening Pressure (Jacket) 0.28 MPa
Power 2 kW + 24 kW
Power Supply 380 V, 50 Hz
Chamber Dimension 550 × 550 × 845 mm
Overall Dimension 1136 × 1310 × 1880 mm
Packing Dimension 1490 × 1450 × 2120 mm
Net Weight 750 kg
Gross Weight 1134 kg
  • Built-in data printer

  • Color touchscreen with graphic display

  • Temperature and pressure recorder

  • Automatic drain system

  • Built-in steam generator

  • Stainless steel construction

  • Double vacuum pulsation

Our Pulse Vacuum Autoclave LBPA-A10 is used for sterilizing medical devices, surgical instruments, dressings, rubber, and liquids. It is Ideal for hospitals, sterile supply departments, and third-party disinfection centers.

Air Compressor

  • Heating Element
  • Printer
  • Pressure Gauge
  • Air Solenoid Valve
  • Safety Valve
  • Temperature Sensor
  • Filter
  • Door Seal
  • Angle Seat Valve

Models of Pulse Vacuum Autoclave

Labtron offers a wide range of Pulse Vacuum Autoclaves to meet the demanding needs of modern healthcare, laboratories, and pharmaceuticals. These autoclaves feature durable stainless-steel chambers, intelligent PLC-based control systems, and automatic drying functions. They are designed in full compliance with international sterilization standards. Our autoclaves utilize a series of vacuum and steam pulses to ensure complete air removal and deep steam penetration, making them ideal for sterilizing complex instruments, porous materials, and packaged items.

Pulse Vacuum Autoclave LBPA-A20

Pulse Vacuum Autoclave LBPA-A20

  • Volume : 257 L
  • Maximum Working Temperature : 139℃
  • Sterilization Temperature Precision : 0 to 2℃
  • Temperature Uniformity : ± 1℃
Pulse Vacuum Autoclave LBPA-A10 FAQ's
  • The door of the autoclave cannot open unless internal pressure is zero and the sterilization cycle is complete. A safety interlock system ensures steam pressure does not build if the door isn't fully sealed. If pressure exceeds 0.027 MPa, the door remains locked. This mechanism prevents accidental burns and steam leaks, protecting both the user and equipment integrity.

  • The autoclave uses a vacuum pump for air removal in multiple pulses (3 to 5 times), which eliminates up to 99.2% of cold air before steam entry. The vacuum pressure reaches up to -97 kPa. Vacuum depth and number of pulses can be adjusted based on the load type. This process ensures even steam penetration and successful sterilization.

  • No, it is not recommended to sterilize different types of items together, such as textiles and liquids or rubber and instruments. Different materials require different sterilization parameters, and mixed loads may result in incomplete sterilization or damage. Separate loads by type for best sterilization results and safety.

  • The autoclave should be used in environments with a temperature between +5°C and +40°C and relative humidity under 85%. It requires a water supply pressure of 0.15 to 0.25 MPa, compressed air between 0.4 and 0.7 MPa, and an AC 380V, 50Hz power supply. The steam input should be between 0.3 and 0.6 MPa to ensure effective operation and avoid equipment damage.

  • Check that air, water, and steam supplies meet required pressure levels. Ensure doors are properly closed and that the chamber gauge reads 0 MPa. Select the desired cycle and input correct parameters. For safety, always review alarms and system status before beginning the cycle to prevent malfunctions.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608