| Volume | 250 L |
| Maximum Working Temperature | 139℃ |
| Sterilization Temperature Precision | 0 to 2℃ |
| Temperature Uniformity | ± 1℃ |
| Design Temperature | 150℃ |
| Maximum Working Pressure | 0.25 MPa |
| Ultimate Vacuum | - 97 kPa |
| Vacuum Leakage Rate | Up to 0.13 kPa/min |
| Negative Pressure Pulsation Amplitude | - 80 to 0 kPa |
| Negative Pressure Pulsation Times | 1 to 99 |
| Times of Positive Pressure Pulses | 1 to 3 |
| Times of Pulses Across Pressure | Amplitude: -80 to 80 kPa, Times: 1 |
| Steam Consumption | 18 kg/C |
| Tap Water Consumption | 120 kg/C |
| Designed Pressure of Inner Chamber | - 0.1 to 0.3 MPa |
| Designed Pressure of Jacket | 0.3 MPa |
| Safety Valve Opening Pressure (Chamber) | 0.28 MPa |
| Safety Valve Opening Pressure (Jacket) | 0.28 MPa |
| Power | 2 kW + 24 kW |
| Power Supply | 380 V, 50 Hz |
| Chamber Dimension | 550 × 550 × 845 mm |
| Overall Dimension | 1136 × 1310 × 1880 mm |
| Packing Dimension | 1490 × 1450 × 2120 mm |
| Net Weight | 750 kg |
| Gross Weight | 1134 kg |
Built-in data printer
Color touchscreen with graphic display
Temperature and pressure recorder
Automatic drain system
Built-in steam generator
Stainless steel construction
Double vacuum pulsation
Our Pulse Vacuum Autoclave LBPA-A10 is used for sterilizing medical devices, surgical instruments, dressings, rubber, and liquids. It is Ideal for hospitals, sterile supply departments, and third-party disinfection centers.
Air Compressor
Download catalog for
Pulse Vacuum Autoclave LBPA-A10 Catalog
Download manual for
Pulse Vacuum Autoclave LBPA-A10 Manual
Labtron offers a wide range of Pulse Vacuum Autoclaves to meet the demanding needs of modern healthcare, laboratories, and pharmaceuticals. These autoclaves feature durable stainless-steel chambers, intelligent PLC-based control systems, and automatic drying functions. They are designed in full compliance with international sterilization standards. Our autoclaves utilize a series of vacuum and steam pulses to ensure complete air removal and deep steam penetration, making them ideal for sterilizing complex instruments, porous materials, and packaged items.

The door of the autoclave cannot open unless internal pressure is zero and the sterilization cycle is complete. A safety interlock system ensures steam pressure does not build if the door isn't fully sealed. If pressure exceeds 0.027 MPa, the door remains locked. This mechanism prevents accidental burns and steam leaks, protecting both the user and equipment integrity.
The autoclave uses a vacuum pump for air removal in multiple pulses (3 to 5 times), which eliminates up to 99.2% of cold air before steam entry. The vacuum pressure reaches up to -97 kPa. Vacuum depth and number of pulses can be adjusted based on the load type. This process ensures even steam penetration and successful sterilization.
No, it is not recommended to sterilize different types of items together, such as textiles and liquids or rubber and instruments. Different materials require different sterilization parameters, and mixed loads may result in incomplete sterilization or damage. Separate loads by type for best sterilization results and safety.
The autoclave should be used in environments with a temperature between +5°C and +40°C and relative humidity under 85%. It requires a water supply pressure of 0.15 to 0.25 MPa, compressed air between 0.4 and 0.7 MPa, and an AC 380V, 50Hz power supply. The steam input should be between 0.3 and 0.6 MPa to ensure effective operation and avoid equipment damage.
Check that air, water, and steam supplies meet required pressure levels. Ensure doors are properly closed and that the chamber gauge reads 0 MPa. Select the desired cycle and input correct parameters. For safety, always review alarms and system status before beginning the cycle to prevent malfunctions.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608