| Test Channel | 4 |
| Wavelength | 470nm |
| Test Items | PT, APTT, TT, FIB |
| Test Principle | Optical colorimetry |
| Detection Time | 20 to 40 seconds can be set arbitrarily from 20 to 99 seconds |
| Sample Incubation Position | 24 |
| Reagent Incubation Position | 6 |
| Detection Position Temperature | 37.0 ± 1.0°C |
| Incubation Position Temperature | 37.0 ± 1.0°C |
| Incubation Time | 1 to 999s |
| Reaction Time | 1 to 99s |
| Reagent Dosage | Minimum dosage 20μl |
| Sample Volume | 20μl to 40μl |
| Ambient Temperature | 10℃ to 30℃ |
| Relative Humidity | ≤80% |
| Atmospheric Pressure | 86kPa to 106kPa |
| Display | 5-inch high-definition color touchscreen |
| Storage | 20,000 results storage, automatically save measurement data when power off |
| Power Consumption | 70VA |
| Power Supply | AC100 to 240V, 50/60Hz |
| Dimension (W × D × H) | 390 × 250 × 135 mm |
| Packaging Dimension (W × D × H) | 445 × 305 × 265 mm |
| Net Weight | 4.96kg |
| Gross Weight | 7kg |
Semi-Automatic Coagulation Analyzer LCAZ-A10 is designed to measure the coagulation properties of blood samples and is used in clinical laboratories, anticoagulant therapy monitoring, preoperative assessment, transfusion medicine, research and development and specialized testing.
Fibrinogen (FIB) Assay Kit
Fibrinogen (FIB) Calibration
Fibrinogen (FIB) Quality Control (Normal)
Fibrinogen (FIB) Quality Control (Abnormal)
Thrombin Time (TT) Assay Kit
Thrombin Time (TT) Quality Control (Normal)
Thrombin Time (TT) Quality Control (Abnormal)
Prothrombin Time (PT) Assay Kit
Prothrombin Time (PT) Quality Control (Normal)
Prothrombin Time (PT) Quality Control (Abnormal)
Activated Partial Thromboplastin Time (APTT) Assay Kit
Activated Partial Thromboplastin Time (APTT) Quality Control (Normal)
Activated Partial Thromboplastin Time (APTT) Quality Control (Abnormal)
Code Scanning Gun
Cuvette
Download catalog for
Semi-Automatic Coagulation Analyzer LCAZ-A10 Catalog
Labtron Semi-Automatic Coagulation Analyzer is specialized to measure clotting parameters of blood with some manual intervention. They utilize photometric or mechanical detection method to measure time taken for thrombus formation after addition of reagents in hemoglobin. Their integrated software analyzes data in real-time, providing instant results for patient management. They incorporate high-speed centrifuges to separate components quickly, ensuring reliable testing outcomes. Our Semi-Automatic Coagulation Analyzer is versatile for monitoring anticoagulant therapy, emergency care, quality control in blood banks and in pregnancy.