Semi-Automatic Coagulation Analyzer LCAZ-A10 is equipped with 4 test channels and utilizes a wavelength of 470 nm. It operates with a detection time of 20 to 40 seconds and a sample volume of 20 μL to 40 μL for rapid results. It is integrated with a 5-inch touchscreen for monitoring and efficient operation. Our analyzer tests for PT, APTT, TT, and FIB provide a comprehensive assessment of coagulation status for effective patient management.
| Test Channel | 4 |
| Wavelength | 470nm |
| Test Items | PT, APTT, TT, FIB |
| Test Principle | Optical colorimetry |
| Detection Time | 20 to 40 seconds can be set arbitrarily from 20 to 99 seconds |
| Sample Incubation Position | 24 |
| Reagent Incubation Position | 6 |
| Detection Position Temperature | 37.0 ± 1.0°C |
| Incubation Position Temperature | 37.0 ± 1.0°C |
| Incubation Time | 1 to 999s |
| Reaction Time | 1 to 99s |
| Reagent Dosage | Minimum dosage 20μl |
| Sample Volume | 20μl to 40μl |
| Ambient Temperature | 10℃ to 30℃ |
| Relative Humidity | ≤80% |
| Atmospheric Pressure | 86kPa to 106kPa |
| Display | 5-inch high-definition color touchscreen |
| Storage | 20,000 results storage, automatically save measurement data when power off |
| Power Consumption | 70VA |
| Power Supply | AC100 to 240V, 50/60Hz |
| Dimension (W × D × H) | 390 × 250 × 135 mm |
| Packaging Dimension (W × D × H) | 445 × 305 × 265 mm |
| Net Weight | 4.96kg |
| Gross Weight | 7kg |
Semi-Automatic Coagulation Analyzer LCAZ-A10 is designed to measure the coagulation properties of blood samples and is used in clinical laboratories, anticoagulant therapy monitoring, preoperative assessment, transfusion medicine, research and development and specialized testing.
| Accessory | Accessory Description |
| Prothrombin Time (PT) Assay Kit(Coagulation) | Freeze-dried Reagent:2mL×10, Reconstitution solution:25mL×1 |
| Prothrombin Time (PT) Quality control | Quality control plasma(normal) 1.0 mL×1 |
| Prothrombin Time (PT) Quality control | Quality control plasma (abnormal) 1.0 mL×1 |
| Activated Partial Thromboplastin Time (APTT)Assay Kit (Coagulation) | Reagent:2mL×10, CaCl₂:25mL×1 |
| Activated Partial Thromboplastin Time (APTT) Quality control | Quality control plasma (normal) 1.0 mL×1 |
| Activated Partial Thromboplastin Time (APTT) Quality control | Quality control plasma (abnormal) 1.0 mL×1 |
| Fibrinogen (FIB) Assay Kit (Coagulation) | Freeze-dried Reagent:2mL×5, Diluent:50mL×2 |
| Fibrinogen (FIB) Calibration | Calibration plasma 1.0 mL×1 |
| Fibrinogen (FIB) Quality control | Quality control plasma (normal) 1.0 mL×1 |
| Fibrinogen (FIB) Quality control | Quality control plasma (abnormal) 1.0 mL×1 |
| Thrombin Time (TT) Assay Kit(Coagulation) | Freeze-dried Reagent 2mL×10, Reconstitution solution 25mL×1 |
| Thrombin Time (TT) Quality control | Quality control plasma (normal) 1.0 mL×1 |
| Thrombin Time (TT) Quality control | Quality control plasma (abnormal) 1.0 mL×1 |
| Code Scanning Gun | |
| Cuvette | 1000pcs/bag |
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom