Our extensive range of test chambers include Temperature and humidity test chamber, Xenon test chamber, Salt spray test chamber, UV test chamber, Aging test chamber, Rain test chamber, High and low temperature chamber, Sand test chamber, Drug test chamber and Ozone test chamber. These chambers are capable to simulate environmental conditions to test various products.
Volume : 150 L
Temperature Range(without illumination) : 0 - 65 °C
Temperature Range(with illumination) : 10 °C - 65°C
Temperature Fluctuation : ± 0.5 °C
Volume : 250 L
Temperature Range(without illumination) : 0 - 65 °C
Temperature Range(with illumination) : 10 °C - 65°C
Temperature Fluctuation : ± 0.5 °C
Volume : 500 L
Temperature Range(without illumination) : 0 - 65 °C
Temperature Range(with illumination) : 10 °C - 65°C
Temperature Fluctuation : ± 0.5 °C
Volume : 150 L
Temperature Range : 0 - 65 °C
Temperature Fluctuation : ± 0.5 °C
Temperature Control Precision : 0.1 °C
Volume : 250 L
Temperature Range : 0 - 65 °C
Temperature Fluctuation : ± 0.5 °C
Temperature Control Precision : 0.1 °C
Volume : 500 L
Temperature Range : 0 - 65 °C
Temperature Fluctuation : ± 0.5 °C
Temperature Control Precision : 0.1 °C
Interior Volume : 100 L
Heat load : 1000 W
Temperature Range : 0℃ to 100 ℃
Temperature Deviation in time : ± 2.0 ℃
Interior Volume : 225 L
Heat load : 1000 W
Temperature Range : 0℃ to 100 ℃
Temperature Deviation in time : ± 2.0 ℃
Interior Volume : 500 L
Heat load : 1000 W
Temperature Range : 0℃ to 100 ℃
Temperature Deviation in time : ± 2.0 ℃
Interior Volume : 800 L
Heat load : 1000 W
Temperature Range : 0℃ to 100 ℃
Temperature Deviation in time : ± 2.0 ℃
Interior Volume : 1000 L
Heat load : 1000 W
Temperature Range : 0℃ to 100 ℃
Temperature Deviation in time : ± 2.0 ℃
Temperature range : 0℃ ~ 100℃
Humidity range : 30 % - 98 % R.H
Temperature fluctuation : ± 0.5 ℃
Speed rate for cooling : Ambient ~ 0 ℃ within 20 min
Diameter of holder (mm) : 400
Length of each side (mm) : 180
Temperature range : 0℃ ~ 100℃
Humidity range : 30 % - 98 % R.H
Diameter of holder (mm) : 600
Length of each side (mm) : 220
Temperature range : 0℃ ~ 100℃
Humidity range : 30 % - 98 % R.H
Diameter of holder (mm) : 700
Length of each side (mm) : 350
Temperature range : 0℃ ~ 100℃
Humidity range : 30 % - 98 % R.H
Diameter of holder (mm) : 900
Length of each side (mm) : 460
Temperature range : 0℃ ~ 100℃
Humidity range : 30 % - 98 % R.H
Chamber Volume : 300 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 450 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 800 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 1000 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 840 L
Temperature Range : With illumination: +10°C to +55°C
Without illumination: +5°C to +50°C
Temperature Uniformity : ± 1℃
Temperature Fluctuation : ± 0.5℃
Chamber Volume : 250 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 300 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 450 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 800 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Chamber Volume : 1000 L
Shelves : 3(PCS)
Display Resolution : 0.1 ℃
Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃
Capacity : 250 L
Temperature Range : With Illumination 10 to 65 °C Without Illumination 0 to 65 °C
Resolution : 0.1 °C
Uniformity : ± 0.1 °C
Chamber volume : 500 L
Temperature range : 20℃ to 70 ℃
Temperature uniformity tolerance : ± 2 ℃
Temperature fluctuation : ± 0.5 ℃
Testing room capacity : 110 L
Temperature range : Ambient to +60°C
Humidity range : 95 to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Testing room capacity : 326 L
Temperature range : Ambient to +60°C
Humidity range : 95 to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Testing room capacity : 410 L
Temperature range : Ambient to +60°C
Humidity range : 95 to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Testing room capacity : 780 L
Temperature range : Ambient to +60°C
Humidity range : 95% to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Testing room capacity : 1030 L
Temperature range : Ambient to +60°C
Humidity range : 95% to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Testing room capacity : 1600 L
Temperature range : Ambient to +60°C
Humidity range : 95% to 98% RH
Temperature Fluctuation : ± 0.5 ℃
Capacity : 780 L
Salt Fog Deposition : 1 to 2 ml/ 80 cm2 hour
Air Preheating : Saturated air barrel (31 L)
Spraying System : Atomized tower and spray nozzles
Temperature range : Ambient to + 50 ℃
Relative Humidity : < 30 % RH
Normal wire diameter : 50 um
Normal width of a gap between wire : 75 um
Temperature range : Ambient to + 50 ℃
Relative Humidity : < 30 % RH
Normal wire diameter : 50 um
Normal width of a gap between wire : 75 um
Temperature range : Ambient to + 50 ℃
Relative Humidity : < 30 % RH
Normal wire diameter : 50 um
Normal width of a gap between wire : 75 um
Temperature range : Ambient to + 50 ℃
Relative Humidity : < 30 % RH
Normal wire diameter : 50 um
Normal width of a gap between wire : 75 um
Capacity : 50 L
Temperature range : (- 20 °C) to 150 °C
Low type : I – 40 °C, II – 70 °C
Environmental condition : 5 ℃ ~ + 40 ℃ ≤ 85 % RH
Capacity : 80 L
Temperature range : (- 20 °C) to 150 °C
Low type : I – 40 °C, II – 70 °C
Environmental condition : 5 ℃ ~ + 40 ℃ ≤ 85 % RH
Capacity : 100 L
Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate : 1 ℃ / min
Overall dimension (D x W x H) : 860 x 1050 x 1620 mm
Capacity : 225 L
Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate : 1 ℃ / min
Overall dimension (D x W x H) : 960 x 1150 x 1860 mm
Capacity : 500 L
Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate : 1 ℃ / min
Overall dimension (D x W x H) : 1180 x 1350 x 2010 mm
Capacity : 800 L
Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate : 1 ℃ / min
Overall dimension (D x W x H) : 1280 x 1550 x 2110 mm
Capacity : 1000 L
Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃
Temperature cooling rate : 1 ℃ / min
Overall dimension (D x W x H) : 1500 x 1550 x 2110 mm
Capacity : 100 L
Temperature range : (-70 )℃ to 150 ℃
Temperature cooling rate : 5 ℃ / min
Overall dimension (D x W x H) : 860 x 1050 x 1620 mm
Capacity : 225 L
Temperature range : (-70 )℃ to 150 ℃
Temperature cooling rate : 5 ℃ / min
Overall dimension (D x W x H) : 960 x 1150 x 1860 mm
Capacity : 500 L
Temperature range : (-70 )℃ to 150 ℃
Temperature cooling rate : 5 ℃ / min
Overall dimension (D x W x H) : 1180 x 1350 x 2010 mm
Capacity : 800 L
Temperature range : (-70 )℃ to 150 ℃
Temperature cooling rate : 5 ℃ / min
Overall dimension (D x W x H) : 1280 x 1550 x 2110 mm
Capacity : 1000 L
Temperature range : (-70 )℃ to 150 ℃
Temperature cooling rate : 5 ℃ / min
Overall dimension (D x W x H) : 1500 x 1550 x 2110 mm
Capacity : 1500 L
Temperature range : (-60) ℃ to +150 ℃
Environmental conditions : 5℃ to +35 ℃ ≤ 85% RH
Loading weight : ≥ 150 Kg
Capacity : 3150 L
Temperature range : -40℃ to 150℃
Temperature cooling rate : 1℃ / min
Temperature heating rate : 1℃ / min
Interior Volume : 700 L
Heat load : 1000 W
Temperature Range : 10℃ to +50 ℃
Temperature Deviation in time : ± 0.1 to 0.3 ℃
Capacity : 150 L
Temperature range : 10 to 70°C
Temperature stability : High: ±0.5℃; Low: ±1℃
Temperature uniformity : ±2°C
UV Temperature : 50 °C to 75 °C
Testing Capacity : 48 piece (75 x 150 mm); 50 piece (75x 150 mm)
Weight : 136 kg
Water Consumption : Distilled water, 8liters per day
Temperature Range : RT + 100 °C ~ 850 °C
Humidity range : At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %
Testing Time : 20 hours
Testing Voltage : 120 V ~ 145 V (135 V)
Temperature Range : RT + 100 °C ~ 630 °C
Humidity range : 30 % ~ 85 % RH
Testing Time : 20 hours
Testing Voltage : 120 V ~ 145 V
Bandwidth Measurement (nm) : 280 ~ 800
Specimen Capacity (pcs) : 28
Specimen holder size (mm) : 80 × 15
Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) : 300 - 420
Specimen Capacity (pcs) : 34
Specimen holder size (mm) : 80 × 15
Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) : 280 ~ 800
Specimen Capacity (pcs) : 28
Specimen holder size (mm) : 80 × 15
Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C
Bandwidth Measurement (nm) : 300 - 420
Specimen Capacity (pcs) : 34
Specimen holder size (mm) : 80 × 15
Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C
Temperature Range : RT+50℃ to 70℃
Temperature Fluctuation : ±3℃
Cooling Way : Air-cooled
Raining Time : 0-99min adjustable