info@labtron.com +44 2080 043608

Test Chamber

Our extensive range of test chambers include Temperature and humidity test chamber, Xenon test chamber, Salt spray test chamber, UV test chamber, Aging test chamber, Rain test chamber, High and low temperature chamber, Sand test chamber, Drug test chamber and Ozone test chamber. These chambers are capable to simulate environmental conditions to test various products.

LDST-B10 Drug Stability Chamber with Illumination LDST-B10

Volume : 150 L

Temperature Range(without illumination) : 0 - 65 °C

Temperature Range(with illumination) : 10 °C - 65°C

Temperature Fluctuation : ± 0.5 °C

LDST-B11 Drug Stability Chamber with Illumination LDST-B11

Volume : 250 L

Temperature Range(without illumination) : 0 - 65 °C

Temperature Range(with illumination) : 10 °C - 65°C

Temperature Fluctuation : ± 0.5 °C

LDST-B12 Drug Stability Chamber with Illumination LDST-B12

Volume : 500 L

Temperature Range(without illumination) : 0 - 65 °C

Temperature Range(with illumination) : 10 °C - 65°C

Temperature Fluctuation : ± 0.5 °C

LDST-A10 Drug Stability Test Chamber LDST-A10

Volume : 150 L

Temperature Range : 0 - 65 °C

Temperature Fluctuation : ± 0.5 °C

Temperature Control Precision : 0.1 °C

LDST-A11 Drug Stability Test Chamber LDST-A11

Volume : 250 L

Temperature Range : 0 - 65 °C

Temperature Fluctuation : ± 0.5 °C

Temperature Control Precision : 0.1 °C

LDST-A12 Drug Stability Test Chamber LDST-A12

Volume : 500 L

Temperature Range : 0 - 65 °C

Temperature Fluctuation : ± 0.5 °C

Temperature Control Precision : 0.1 °C

LDST-A20 Drug Stability Test Chamber LDST-A20

Interior Volume : 100 L

Heat load : 1000 W

Temperature Range : 0℃ to 100 ℃

Temperature Deviation in time : ± 2.0 ℃

LDST-A21 Drug Stability Test Chamber LDST-A21

Interior Volume : 225 L

Heat load : 1000 W

Temperature Range : 0℃ to 100 ℃

Temperature Deviation in time : ± 2.0 ℃

LDST-A22 Drug Stability Test Chamber LDST-A22

Interior Volume : 500 L

Heat load : 1000 W

Temperature Range : 0℃ to 100 ℃

Temperature Deviation in time : ± 2.0 ℃

LDST-A23 Drug Stability Test Chamber LDST-A23

Interior Volume : 800 L

Heat load : 1000 W

Temperature Range : 0℃ to 100 ℃

Temperature Deviation in time : ± 2.0 ℃

LDST-A24 Drug Stability Test Chamber LDST-A24

Interior Volume : 1000 L

Heat load : 1000 W

Temperature Range : 0℃ to 100 ℃

Temperature Deviation in time : ± 2.0 ℃

LOC-A10 Ozone Test Chamber LOC-A10

Temperature range : 0℃ ~ 100℃

Humidity range : 30 % - 98 % R.H

Temperature fluctuation : ± 0.5 ℃

Speed rate for cooling : Ambient ~ 0 ℃ within 20 min

LOC-A11 Ozone Test Chamber LOC-A11

Diameter of holder (mm) : 400

Length of each side (mm) : 180

Temperature range : 0℃ ~ 100℃

Humidity range : 30 % - 98 % R.H

LOC-A12 Ozone Test Chamber LOC-A12

Diameter of holder (mm) : 600

Length of each side (mm) : 220

Temperature range : 0℃ ~ 100℃

Humidity range : 30 % - 98 % R.H

LOC-A13 Ozone Test Chamber LOC-A13

Diameter of holder (mm) : 700

Length of each side (mm) : 350

Temperature range : 0℃ ~ 100℃

Humidity range : 30 % - 98 % R.H

LOC-A14 Ozone Test Chamber LOC-A14

Diameter of holder (mm) : 900

Length of each side (mm) : 460

Temperature range : 0℃ ~ 100℃

Humidity range : 30 % - 98 % R.H

LPGC-A10 Plant Growth Chamber LPGC-A10

Chamber Volume : 300 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-A11 Plant Growth Chamber LPGC-A11

Chamber Volume : 450 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-A12 Plant Growth Chamber LPGC-A12

Chamber Volume : 800 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-A13 Plant Growth Chamber LPGC-A13

Chamber Volume : 1000 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-A20 Plant Growth Chamber LPGC-A20

Chamber Volume : 840 L

Temperature Range : With illumination: +10°C to +55°C
Without illumination: +5°C to +50°C

Temperature Uniformity : ± 1℃

Temperature Fluctuation : ± 0.5℃

LPGC-B10 Plant Growth Chamber LPGC-B10

Chamber Volume : 250 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-B11 Plant Growth Chamber LPGC-B11

Chamber Volume : 300 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-B12 Plant Growth Chamber LPGC-B12

Chamber Volume : 450 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-B13 Plant Growth Chamber LPGC-B13

Chamber Volume : 800 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-B14 Plant Growth Chamber LPGC-B14

Chamber Volume : 1000 L

Shelves : 3(PCS)

Display Resolution : 0.1 ℃

Temperature Range : Without Lighting: 0 to 50℃
With lighting:10 to 50℃

LPGC-B15 Plant Growth Chamber LPGC-B15

Capacity : 250 L

Temperature Range : With Illumination 10 to 65 °C Without Illumination 0 to 65 °C

Resolution : 0.1 °C

Uniformity : ± 0.1 °C

LPGC-C10 Plant Growth Chamber LPGC-C10

Chamber volume : 500 L

Temperature range : 20℃ to 70 ℃

Temperature uniformity tolerance : ± 2 ℃

Temperature fluctuation : ± 0.5 ℃

LSSC-A10 Salt Spray Test Chamber LSSC-A10

Testing room capacity : 110 L

Temperature range : Ambient to +60°C

Humidity range : 95 to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-A11 Salt Spray Test Chamber LSSC-A11

Testing room capacity : 326 L

Temperature range : Ambient to +60°C

Humidity range : 95 to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-A12 Salt Spray Test Chamber LSSC-A12

Testing room capacity : 410 L

Temperature range : Ambient to +60°C

Humidity range : 95 to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-A13 Salt Spray Test Chamber LSSC-A13

Testing room capacity : 780 L

Temperature range : Ambient to +60°C

Humidity range : 95% to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-A14 Salt Spray Test Chamber LSSC-A14

Testing room capacity : 1030 L

Temperature range : Ambient to +60°C

Humidity range : 95% to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-A15 Salt Spray Test Chamber LSSC-A15

Testing room capacity : 1600 L

Temperature range : Ambient to +60°C

Humidity range : 95% to 98% RH

Temperature Fluctuation : ± 0.5 ℃

LSSC-B10 Salt Spray Test Chamber LSSC-B10

Capacity : 780 L

Salt Fog Deposition : 1 to 2 ml/ 80 cm2 hour

Air Preheating : Saturated air barrel (31 L)

Spraying System : Atomized tower and spray nozzles

LSC-A10 Sand and Dust Test Chamber LSC-A10

Temperature range : Ambient to + 50 ℃

Relative Humidity : < 30 % RH

Normal wire diameter : 50 um

Normal width of a gap between wire : 75 um

LSC-A11 Sand and Dust Test Chamber LSC-A11

Temperature range : Ambient to + 50 ℃

Relative Humidity : < 30 % RH

Normal wire diameter : 50 um

Normal width of a gap between wire : 75 um

LSC-A12 Sand and Dust Test Chamber LSC-A12

Temperature range : Ambient to + 50 ℃

Relative Humidity : < 30 % RH

Normal wire diameter : 50 um

Normal width of a gap between wire : 75 um

LSC-A13 Sand and Dust Test Chamber LSC-A13

Temperature range : Ambient to + 50 ℃

Relative Humidity : < 30 % RH

Normal wire diameter : 50 um

Normal width of a gap between wire : 75 um

LTHC-A10 Temperature and Humidity Test Chamber LTHC-A10

Capacity : 50 L

Temperature range : (- 20 °C) to 150 °C

Low type : I – 40 °C, II – 70 °C

Environmental condition : 5 ℃ ~ + 40 ℃ ≤ 85 % RH

LTHC-A11 Temperature and Humidity Test Chamber LTHC-A11

Capacity : 80 L

Temperature range : (- 20 °C) to 150 °C

Low type : I – 40 °C, II – 70 °C

Environmental condition : 5 ℃ ~ + 40 ℃ ≤ 85 % RH

LTHC-B10 Temperature and Humidity Test Chamber LTHC-B10

Capacity : 100 L

Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃

Temperature cooling rate : 1 ℃ / min

Overall dimension (D x W x H) : 860 x 1050 x 1620 mm

LTHC-B11 Temperature and Humidity Test Chamber LTHC-B11

Capacity : 225 L

Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃

Temperature cooling rate : 1 ℃ / min

Overall dimension (D x W x H) : 960 x 1150 x 1860 mm

LTHC-B12 Temperature and Humidity Test Chamber LTHC-B12

Capacity : 500 L

Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃

Temperature cooling rate : 1 ℃ / min

Overall dimension (D x W x H) : 1180 x 1350 x 2010 mm

LTHC-B13 Temperature and Humidity Test Chamber LTHC-B13

Capacity : 800 L

Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃

Temperature cooling rate : 1 ℃ / min

Overall dimension (D x W x H) : 1280 x 1550 x 2110 mm

LTHC-B14 Temperature and Humidity Test Chamber LTHC-B14

Capacity : 1000 L

Temperature range : (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃

Temperature cooling rate : 1 ℃ / min

Overall dimension (D x W x H) : 1500 x 1550 x 2110 mm

LTHC-B20 Temperature and Humidity Test Chamber LTHC-B20

Capacity : 100 L

Temperature range : (-70 )℃ to 150 ℃

Temperature cooling rate : 5 ℃ / min

Overall dimension (D x W x H) : 860 x 1050 x 1620 mm

LTHC-B21 Temperature and Humidity Test Chamber LTHC-B21

Capacity : 225 L

Temperature range : (-70 )℃ to 150 ℃

Temperature cooling rate : 5 ℃ / min

Overall dimension (D x W x H) : 960 x 1150 x 1860 mm

LTHC-B22 Temperature and Humidity Test Chamber LTHC-B22

Capacity : 500 L

Temperature range : (-70 )℃ to 150 ℃

Temperature cooling rate : 5 ℃ / min

Overall dimension (D x W x H) : 1180 x 1350 x 2010 mm

LTHC-B23 Temperature and Humidity Test Chamber LTHC-B23

Capacity : 800 L

Temperature range : (-70 )℃ to 150 ℃

Temperature cooling rate : 5 ℃ / min

Overall dimension (D x W x H) : 1280 x 1550 x 2110 mm

LTHC-B24 Temperature and Humidity Test Chamber LTHC-B24

Capacity : 1000 L

Temperature range : (-70 )℃ to 150 ℃

Temperature cooling rate : 5 ℃ / min

Overall dimension (D x W x H) : 1500 x 1550 x 2110 mm

LTHC-B25 Temperature and Humidity Test Chamber LTHC-B25

Capacity : 1500 L

Temperature range : (-60) ℃ to +150 ℃

Environmental conditions : 5℃ to +35 ℃ ≤ 85% RH

Loading weight : ≥ 150 Kg

LTHC-B30 Temperature and Humidity Test Chamber LTHC-B30

Capacity : 3150 L

Temperature range : -40℃ to 150℃

Temperature cooling rate : 1℃ / min

Temperature heating rate : 1℃ / min

LTHC-C10 Temperature and Humidity Test Chamber LTHC-C10

Interior Volume : 700 L

Heat load : 1000 W

Temperature Range : 10℃ to +50 ℃

Temperature Deviation in time : ± 0.1 to 0.3 ℃

LTHC-C20 Temperature and Humidity Test Chamber LTHC-C20

Capacity : 150 L

Temperature range : 10 to 70°C

Temperature stability : High: ±0.5℃; Low: ±1℃

Temperature uniformity : ±2°C

LUVC-A10 UV Test Chamber LUVC-A10

UV Temperature : 50 °C to 75 °C

Testing Capacity : 48 piece (75 x 150 mm); 50 piece (75x 150 mm)

Weight : 136 kg

Water Consumption : Distilled water, 8liters per day

LUVC-A20 UV Test Chamber LUVC-A20

Temperature Range : RT + 100 °C ~ 850 °C

Humidity range : At 400 °C: R.H. is 40 % ~ 85 % / At 800 °C: R.H. is 30 % ~ 50 %

Testing Time : 20 hours

Testing Voltage : 120 V ~ 145 V (135 V)

LUVC-A21 UV Test Chamber LUVC-A21

Temperature Range : RT + 100 °C ~ 630 °C

Humidity range : 30 % ~ 85 % RH

Testing Time : 20 hours

Testing Voltage : 120 V ~ 145 V

LXC-A10 Xenon Test Chamber LXC-A10

Bandwidth Measurement (nm) : 280 ~ 800

Specimen Capacity (pcs) : 28

Specimen holder size (mm) : 80 × 15

Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C

LXC-A11 Xenon Test Chamber LXC-A11

Bandwidth Measurement (nm) : 300 - 420

Specimen Capacity (pcs) : 34

Specimen holder size (mm) : 80 × 15

Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C

LXC-A20 Xenon Test Chamber LXC-A20

Bandwidth Measurement (nm) : 280 ~ 800

Specimen Capacity (pcs) : 28

Specimen holder size (mm) : 80 × 15

Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C

LXC-A21 Xenon Test Chamber LXC-A21

Bandwidth Measurement (nm) : 300 - 420

Specimen Capacity (pcs) : 34

Specimen holder size (mm) : 80 × 15

Chamber Temperature Range : Ambient ~ 100 ℃ ± 2 °C

LXC-A22 Xenon Test Chamber LXC-A22

Temperature Range : RT+50℃ to 70℃

Temperature Fluctuation : ±3℃

Cooling Way : Air-cooled

Raining Time : 0-99min adjustable


Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608