| Working Gas | Nitrogen, Argon, Helium |
| Water & Oxygen Index | Less than 1 ppm |
| Circulation Capacity | Integrated fan, 90m³/h |
| Material | 304 stainless steel, 3mm thick |
| Internal Dimensions | 1220 × 750× 900mm |
| Window | Tempered glass, 8mm thick |
| Glove Ports | Anodized aluminum, O-ring enclosed |
| Gloves | Butyl rubber, 0.4mm thick, Ø 7 inch |
| Pressure Control | PLC controlled, ±15 mbar |
| Big Passing Box | Ø 360mm × 600mm, double-gate, anodized aluminum, 10mm thick |
| Small Passing Box | Ø 100mm × 300mm, double-gate, screw-threaded coupling |
| Filter | 0.3μm (0.12μm optional) |
| Shelf | Stainless steel, 2 levels |
| Lighting | Fluorescent lamp |
| Gas Purification | Dehydration & deoxidization with 4.5kg copper catalyst, 4.5kg molecular sieve |
| Purification Capacity | Deoxidization: 36L, Dehydration: 1.3kg |
| Gas Cycling System | Nitrogen/Argon, 90m³/h, frequency conversion |
| Regeneration Gas | 5-10% hydrogen mixed gas |
| Vacuum Pump | 12m³/h rotary pump (8m³/h optional) |
| Main Valve | DN 40 KF, electronic pneumatic |
| Control Valve | Electronic pneumatic valve |
| Control System | Siemens PLC, touch panel |
| Foot Switch | Controls box pressure |
| Display System | Siemens PLC, pressure display |
| Power Supply | 220V |
| Dimension (L×D×H) | 1220 × 750 × 900mm |
| Overall Dimension | 1225 × 1810 × 982mm |
| Net Weight | 560kg |
| Gross Weight | 760kg |
Real-time monitoring with touchscreen display
Integrated vacuum pump system
Supports nitrogen and argon operation
Integrated LED lighting system
Efficient gas purification unit
Adjustable working pressure settings
Easy maintenance and system calibration
Anti-reflective front panel
Overload protection safety system
Our Single Station Glove Box LSGB-A10 maintains ultra-low moisture and oxygen levels, ideal for semiconductor fabrication, battery research, and chemical synthesis. Its automated purification and pressure control system ensure efficiency in inert gas applications.
| Accessory Name | Quantity |
| Vacuum Pump | 1 |
| Oxygen Analyzer | 1 |
| Dew Point Analyzer | 1 |
Labtron Single Station Glove Box is designed to provide an inert workspace for precise scientific and manufacturing tasks. These feature real-time monitoring with a touchscreen interface for accurate control and adjustments. Their vacuum pump and purification system maintain ultra-low oxygen and humidity levels. They include a spacious antechamber, automated pressure regulation, and customizable working parameters. Our glove boxes support laboratories, semiconductor fabrication, battery assembly, pharmaceutical production, and aerospace research.



Our Single Station Glove Box is ideal for handling sensitive materials that require a controlled, inert atmosphere. It can be used for various applications, including research and industrial processes involving materials that are sensitive to oxygen and moisture. The glove box’s low oxygen and moisture levels ensure safe handling of materials like powders, chemicals, and electronic components. This makes it perfect for both delicate and high-stakes operations.
The Single Station Glove Box is designed for easy maintenance with an automated cleaning system that ensures efficient gas replacement and purification. The vacuum pump and gas purification system can be easily checked and serviced. Additionally, its sealed design minimizes contamination risks, making regular cleaning tasks straightforward and time-saving.
The Single Station Glove Box is equipped with automatic pressure regulation, overload protection, and a sealed chamber to prevent leaks. The PLC control system ensures that pressure fluctuations are managed safely, reducing the risk of accidents while working with sensitive materials.
Labtron’s Single Station Glove Box gas purification system has a long lifespan, but it’s important to check it periodically for optimal performance. Our glove box is designed for easy filter changes, and regenerating the purification system ensures its continued efficiency. The frequency of maintenance depends on usage conditions and how often the system is in operation.
Our Single Station Glove Box ensures a contaminant-free workspace with an advanced gas purification system that removes moisture and oxygen. The continuous circulation of purified gases like nitrogen or argon maintains a stable internal atmosphere. The sealed stainless steel chamber prevents external contamination, while airtight glove ports provide secure handling. Automated pressure regulation further enhances safety by preventing fluctuations that could affect sensitive materials.
The Single Station Glove Box features a PLC-controlled pressure regulation system that maintains internal pressure within ±15 mbar. Automatic adjustments prevent sudden fluctuations, ensuring stability for delicate processes. The foot switch allows easy control, while electronic pneumatic valves provide precise pressure management. These features enhance safety and prevent damage to sensitive samples.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608