Spectral colorimeter LCS-A12 with high precision, is adopted with spectral measurement working theory which greatly improves the accuracy of colorimeter. The superior leather design, helps in increasing the friction in case of fingers sliding. It comes with multiple light source for measurements & has metameric index, staining fastness, color fastness for color measurements in textile industry.
Illumination | Di / 8 (diffusion illumination, 8° viewing), SCI |
Size of integrated sphere | 40 mm, avian diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Sensor array |
Wavelength | 400 - 700 nm |
Spectral resolution | 10 nm |
Measuring time | 2 s |
Measurement caliber size | 11 mm |
Optional measurement caliber size | 4 mm, 6 mm, 15 mm |
Repeatability | Standard deviation ΔE × ab 0.08 (when a white calibration plate is measured 30x at 10 second interval after calibration) |
Observe angles | 2° and 10° |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF, U35 |
Camera attachment | camera viewing for measurement |
Display |
Chromaticity value(L × a × b,L × C × h), ΔE value, pass / fail, color tendency, average, generate test report With camera to see the measurement area, spectrum reflectance figure data, manual input target data |
Color difference formula | ΔE × ab, ΔE × CH, ΔE × uv,ΔE × cmc(2:1),ΔE × cmc(1:1),ΔE × 94,ΔE × 00 |
Color space | CIE-L × a × b, L × C × h, L × uv, XYZ, Yxy, reflectance |
Measurement indices |
WI (whiteness indices)(ASTM E313-10,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube Berger,Ganz,Stensby) YI (yellowness indices) (ASTM D1925,ASTM E313-00,ASTM E313-73) Metameric index, staining fastness, color fastness |
Data storage | 100 targets and 200 samples |
Light source lifetime | 5 years, 1.5 million times |
Screen | Panchromatic True Color Screen |
Interface | USB 2.0 |
Other function | Input color swatches |
Working temperature | 5 ~ 45 °C, relative humidity 80 % or below( at 35 °C ),no condensation |
Storage temperature | (-25 to 55 °C), relative humidity 80 % or below( at 35 °C ),no condensation |
Power | Rechargeable Lithium battery, 8.4 V / 2000 mAh, adaptor DC 12 V |
Dimension | 77 × 86 × 210 mm |
Weight | 550 g |
Spectral colorimeter is widely used for plastic, printing, paint, ink, textile, dyeing, food, chemical and other industries for color management.
Micro printer
Model | Illumination | Size of integrated sphere | Illumination light source | Sensor | Wavelength | Spectral resolution | Measuring time | Measurement caliber size | Optional measurement caliber size | Repeatability | Observe angles | Light source | Camera attachment | Display | Color difference formula | Color space | Measurement indices | Data storage | Light source lifetime | Screen | Interface | Other function | Working temperature | Storage temperature | Power | Dimension | Weight |
LCS-A10 | Di / 8 (diffusion illumination, 8° viewing), SCI | 40 mm, alvan diffused reflection surface coating | CLED | Sensor array | 400 - 700 nm | 10 nm | 2 s | 11 mm | 4 mm, 6 mm, 15 mm | Standard deviation ΔE × ab 0.08 (when a white calibration plate is measured 30x at 10 second interval after calibration) | 2° and 10° | A,C,D50 & D65 | Without camera | Chromaticity value(L × a × b,L × C × h), ΔE value, pass / fail, color tendency, average, generate test report | ΔE × ab, ΔE × CH | CIE - L × a × b, L × C × h, reflectance | Nil | 100 targets and 200 samples | 5 years, 1.5 million times | Panchromatic True Color Screen | USB 2.0 | - | 5 ~ 45 °C, relative humidity 80 % or below( at 35 °C ),no condensation | (-25 to 55 °C), relative humidity 80 % or below( at 35 °C ),no condensation | Rechargeable Lithium battery, 8.4 V / 2000 mAh, adaptor DC 12 V | 77 × 86 × 210 mm | 550 g |
LCS-A12 | Di / 8 (diffusion illumination, 8° viewing), SCI | 40 mm, avian diffused reflection surface coating | CLED | Sensor array | 400 - 700 nm | 10 nm | 2 s | 11 mm | 4 mm, 6 mm, 15 mm | Standard deviation ΔE × ab 0.08 (when a white calibration plate is measured 30x at 10 second interval after calibration) | 2° and 10° | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF, U35 | camera viewing for measurement |
Chromaticity value(L × a × b,L × C × h), ΔE value, pass / fail, color tendency, average, generate test report With camera to see the measurement area, spectrum reflectance figure data, manual input target data |
ΔE × ab, ΔE × CH, ΔE × uv,ΔE × cmc(2:1),ΔE × cmc(1:1),ΔE × 94,ΔE × 00 | CIE-L × a × b, L × C × h, L × uv, XYZ, Yxy, reflectance |
WI (whiteness indices)(ASTM E313-10,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube Berger,Ganz,Stensby) YI (yellowness indices) (ASTM D1925,ASTM E313-00,ASTM E313-73) Metameric index, staining fastness, color fastness |
100 targets and 200 samples | 5 years, 1.5 million times | Panchromatic True Color Screen | USB 2.0 | Input color swatches | 5 ~ 45 °C, relative humidity 80 % or below( at 35 °C ),no condensation | (-25 to 55 °C), relative humidity 80 % or below( at 35 °C ),no condensation | Rechargeable Lithium battery, 8.4 V / 2000 mAh, adaptor DC 12 V | 77 × 86 × 210 mm | 550 g |
LCS-A11 | - | - | - | Array | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | USB, Bluetooth | - | - | - | - | - | - |