| Capacity | 64 L |
| Temperature Range | - 20 ℃ to + 150 ℃ (Optional + 180 ℃) |
| Temperature Uniformity | less than or equal to 2.0 °C |
| Temperature Fluctuation | ± 0.5 ℃ |
| Heating Rate | - 20 ℃ to + 100 ℃ (3 ℃/min) |
| Cooling Rate | + 20 ℃ to – 20 ℃ (3 ℃/min) |
| Operating Ambient Temperature | 5 °C to 35 °C |
| Floor Space | 0.82 m² |
| Controller | 7-inch touch screen controller |
| Communication Interface | USB, RS-232/485, and LAN |
| Refrigeration System | Hermetic compressor, single stage or cascade refrigeration system |
| Interior Chamber Material | SUS304 stainless-steel plate |
| Exterior Chamber Material | High quality cold rolled steel plate, surface electrostatic powder coating |
| Insulation Material | Rigid polyurethane foam insulation layer, flame retardant grade B2 |
| Power Consumption | 5 KW |
| Power supply | AC 380V ±10% 50Hz / AC 220V ±10% 50Hz |
| Internal Dimensions | 400 × 400 × 400 mm |
| External Dimensions | 700 × 1652 × 1170 mm |
| Package Dimensions | 920 × 1820 × 1350 mm |
| Net Weight | 320 Kg |
| Gross Weight | 550 Kg |
User Friendly Interface
Energy Efficient Unit
Customizable Settings
Low Heat Emission
Uniform Airflow Distribution
Our chamber is widely utilized in electronics, automotive, aerospace, defense, research institutions, and various industrial sectors for testing product durability, reliability, and performance under controlled temperature conditions.
| Accessories | Quantity | Unit |
| Observation Window light | 1 | Set |
| Mobile casters (with foot cups) | 4 | Pieces |
| Cable ports (50 mm with silicone plugs) | 2 | Units |
| Sample racks | 2 | Layers |
| Internal lighting | 1 | Set |
| Power cord | 5 | Meters |
Download catalog for
High-Low Temperature Test Chamber LTTC-C10 Catalog
Labtron Temperature Test Chambers are designed for controlled environmental testing across industrial and research applications. They feature a balanced temperature control system, ensuring uniform heating and cooling for stable performance. These chambers have SUS304 stainless steel interiors with advanced insulation to enhance efficiency and durability. Their programmable touchscreen controller allows easy operation with multiple communication interfaces for smooth data transfer. Our Temperature Test Chambers are ideal for reliability testing, material evaluation, and electronic component assessments.








Yes, The High-Low Temperature Test Chamber LTTC-C10 is designed to simulate a wide range of temperature and humidity conditions, including extreme scenarios. Some models can reach sub-zero temperatures and very high humidity levels to replicate harsh field conditions. This makes them suitable for aerospace, military, and automotive applications where components must perform under severe climate changes. Rapid ramp rates allow quick transition between different environmental conditions. These capabilities help in identifying failure points, material degradation, and long-term durability. By replicating these conditions in a controlled lab setting, companies can assess how products will perform globally. This simulation ability is essential for product development and validation.
High-Low Temperature Test Chamber LTTC-C10 typically include built-in data logging systems to track performance throughout the test. Measurements such as temperature, humidity, and time are continuously recorded and stored in the chamber’s memory or an external USB. Many units offer PC connectivity via Ethernet, RS-232/485, or Wi-Fi for remote monitoring and data extraction. The data can be visualized in real-time through graphs or exported in formats like CSV or PDF for further analysis. This recorded data ensures traceability, helps troubleshoot issues, and supports regulatory documentation. For advanced needs, chambers can be integrated with software that allows automated reporting and multi-chamber management. Reliable data capture is essential for maintaining testing accuracy and compliance.
High-Low Temperature Test Chamber LTTC-C10 is built using materials that enhance performance, hygiene, and durability. The inner walls are typically made from stainless steel, which resists corrosion, is easy to clean, and does not react with test samples. The exterior is often constructed from cold-rolled steel with a powder-coated finish for structural strength and rust resistance. Polyurethane foam insulation is commonly used between the inner and outer walls to minimize heat transfer and improve energy efficiency. Doors may include silicone gaskets to maintain a tight seal and prevent air leakage. Observation windows are usually made from multi-layered tempered glass with anti-fog coatings. These construction materials contribute to the chamber’s long-term reliability and consistent performance.
The basic principle involves a closed-loop feedback system that constantly adjusts internal conditions based on sensor input. A heater and refrigeration unit work together to increase or decrease the internal temperature as needed. Humidification is typically achieved through a steam generator or ultrasonic humidifier, while dehumidification is managed using a cooling coil to condense excess moisture. Precision sensors monitor the current temperature and relative humidity levels. These readings are compared to the preset values in the controller, which then sends signals to adjust the heating, cooling, or humidifying components accordingly. This system allows the chamber to maintain stable environmental conditions regardless of external influences. The process is automated to ensure accuracy and repeatability throughout testing cycles.
Uniform airflow is essential to maintain consistent temperature and humidity levels throughout the testing space. The chamber uses specially designed circulation fans and duct systems to evenly distribute conditioned air. Baffles and airflow channels are strategically placed to eliminate hotspots and cold zones. This design ensures that every part of the test sample receives the same environmental exposure. Consistent airflow also aids in faster recovery times when the door is opened or conditions are changed. Without proper airflow, test results could vary significantly depending on sample placement. Manufacturers optimize airflow based on chamber size and performance requirements to guarantee uniformity.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608