Total Phosphorus Analyzer LTPA-A10

Total Phosphorus Analyzer LTPA-A10

Total Phosphorus Analyzer LTPA-A10 measures 0.02 to 10 mg/L, extendable with dilution or spiking. Uses cold light and monochromatic light sources for excellent optical stability and resistance to interference from external light. The high-temperature digestion unit is kept separate from the main unit to protect the optical system from heat. Built with a molded ABS housing that offers excellent corrosion resistance Our total phosphorus analyzer can store up to 10 working curves and 500 historical records, with data protection even during power outages.

Request Quote
Measuring Range 0.02 to 10 mg/L (Exceeds dilution or spike range)
Indication Error ≤ ±5% (F.S.)
Repeatability ≤ 3%
Digestion Temperature 120°C ±1.0°C
Digestion Time 30 minutes
Optical Stability ≤ 0.002A / 20 minutes
Batch Capacity 16 water samples / 20 water samples
Power Consumption 400 W
Dimension (Main Unit) 266 × 200 × 130 mm
Dimension (Digestion Unit) 216 × 320 × 146 mm
Dimension 420 × 240 × 330 mm
Packaging Dimension 450 × 350 × 270 mm
Net Weight 2.5 Kg
Gross Weight 7.35 Kg
  • PID automatic control

  • Large LCD display

  • Calibration

  • Incorporates V/F conversion

Total Phosphorus Analyzer LTPA-A10 is used to measure phosphorus in groundwater, surface water, sewage, industrial wastewater, and for environmental monitoring.

Accessories Name Quantity 
16-well Digester1 unit
Digestion Colorimetric Tubes10 pcs
Total Phosphorus Reagent Set1 set (sufficient for 100 samples)
Test Tube Rack1 pc
Protective Cover1 pc
Power Cord1 pc
Accessories Name Quantity
 Each Digestion colorimetric tubes and total phosphorus reagent9 sets 
Total Digestion colorimetric tubes and total phosphorus reagent9 sets
A box containing colorimetric tube10 pcs
Total Phosphorus Analyzer LTPA-A10 FAQ's
  • The Labtron Total Phosphorus Analyzer LTPA-A10 comes with 1 set of digestion colorimetric tubes and a total phosphorus reagent set. This reagent set is sufficient to perform 100 tests. The inclusion of these consumables ensures that users can begin testing immediately after installation without the need for additional purchases. When more tests are required, optional reagent sets and extra digestion colorimetric tubes can be supplied, making the system convenient and cost-effective for routine laboratory and environmental monitoring work.

  • The Labtron Total Phosphorus Analyzer LTPA-A10 can measure phosphorus concentrations ranging from 0.02 to 10 mg/L. If your sample has a higher concentration than this range, the measurement can still be extended by using sample dilution or spiking methods. This ensures the analyzer can cover a wide range of applications, from low-level phosphorus monitoring to higher concentration testing in wastewater or industrial samples.

  • Labtron LTPA-A10 uses cold light and monochromatic light sources, which provide excellent optical stability and minimize interference from external light sources. The design also keeps the high-temperature digestion unit separate from the main optical system, preventing heat damage and ensuring consistent accuracy. Additionally, it features optical stability ? 0.002A/20 minutes, which means the readings remain highly reliable over time.

  • The analyzer is designed with a molded ABS housing that offers strong resistance against corrosion, making it suitable for tough environments. Its compact design, light weight (2.5 kg net), and data storage capacity of up to 10 working curves and 500 historical records make it highly user-friendly. Even during a power outage, the stored data remains protected. These features make Labtron LTPA-A10 reliable for routine lab testing as well as on-site environmental monitoring.

  • Labtron provides a complete set of standard accessories with the LTPA-A10 to support accurate testing. These include a 16-well digester, digestion colorimetric tubes (10 pcs), a total phosphorus reagent set (enough for 100 samples), a test tube rack, protective cover, and power cord. Optional accessories like additional digestion colorimetric tubes, reagents, and tube boxes are also available. This ensures the analyzer is ready to use immediately, with easy options for replenishment when consumables run low.

  • Labtron LTPA-A10 is widely used in environmental monitoring and water quality testing. It can measure phosphorus in groundwater, surface water, sewage, and industrial wastewater. This makes it suitable for environmental agencies, wastewater treatment plants, research laboratories, and industries that need to comply with water quality regulations. By providing quick and precise results within 30 minutes of digestion, it helps ensure that water sources are monitored effectively and pollution levels are controlled.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.