| Flow Rate | 18000 L/H |
| Vacuum Degree | -0.08 to -0.099 MPa |
| Vacuum Pressure | ≤ 0.3 MPa |
| Temperature Range | 20 to 80℃ |
| Working Noise | 75 dB(A) |
| Oil Outlet/Inlet | Φ 63 mm |
| Moisture Content | ≤3 PPM |
| Gas Content | 0.1 % |
| Impurity Size | ≤1 μm |
| Value β | 98 % |
| Cleanness | ≤ 6 |
| Heating Power | 180,000 W |
| Power Consumption | 196,000 W |
| Power Supply | AC380V/50Hz/3 |
| Dimensions (L×W×H) | 2200 × 1600 × 2200 mm |
| Weight | 1900 kg |
Plug-and-play integration feature
Safety shutdown mechanism
Real-time contamination detection
Automatic temperature control
Anti-leak protection
Double-Stage Vacuum Transformer Oil Purifier LDOP-A16 purifies transformer oils and electrical insulating liquids by removing moisture, gas, and impurities. It is used in industrial applications like workshops, storage tanks, and transformers.
Download catalog for
Double-Stage Vacuum Transformer Oil Purifier LDOP-A16 Catalog
Available Range :
Double-Stage Vacuum Transformer Oil Purifier LDOP-A14 : 12000 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A15 : 15000 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A10 : 1800 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A16 : 18000 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A11 : 3000 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A12 : 6000 L/H Double-Stage Vacuum Transformer Oil Purifier LDOP-A13 : 9000 L/HLabtron Vacuum Transformer Oil Purifier includes vacuum primary and booster roots pump to ensure high vacuum efficiency, reducing oil water content. These offer automatic anti-foam control system to prevent foam formation for smooth, uninterrupted operation. The multi-stage purification system removes impurities with standardized filters for thorough purification. They feature a weather-proof enclosure to protect against rain, dust, and sunlight. Our Vacuum Transformer Oil Purifier supports remote monitoring for convenient operation and diagnostics.






Our Double-Stage Vacuum Transformer Oil Purifier is built for rugged conditions, featuring a compact frame, weather-resistant enclosures, and consistent performance across temperature fluctuations. It can be installed on mobile skids or trailers for field-based transformer servicing. The low noise level (75 dB) ensures compatibility with indoor substations or urban settings. Its automatic systems (foam control, temperature regulation) allow for semi-autonomous operation in unmanned stations. Our system is well-suited for remote oil farms, desert substations, or high-humidity tropical zones.
The Double-Stage Vacuum Transformer Oil Purifier offers deeper vacuum levels and faster processing compared to single-stage units. Our dual-stage vacuum pumps remove more moisture and gases, resulting in cleaner and drier oil. This improves the dielectric strength and performance of transformers significantly. It’s especially advantageous for high-voltage transformers or systems in continuous operation. Our two-stage system ensures long-term reliability and superior oil conditioning.
Our Double-Stage Vacuum Transformer Oil Purifier is equipped with a real-time contamination detection system that allows for continuous tracking of moisture and particulate levels during operation. This feature helps operators react immediately to spikes in contamination, preventing damage to the transformer. With data on moisture and solid impurity levels, maintenance decisions are based on actual oil conditions. It improves operational transparency and allows predictive maintenance planning. The ability to monitor contamination live greatly enhances safety and oil quality assurance.
Extend the life of the transformer with the Double-Stage Vacuum Transformer Oil Purifier, which removes impurities like dissolved gases, moisture, and micro-particles that degrade oil quality. Prevents oxidation, sludge formation, and loss of dielectric strength by maintaining clean, high-performance oil. Our oil purifier restores insulation strength and cooling efficiency to ensure reliable transformer operation. Reduces the risk of electrical failures and improves overall equipment longevity. Avoid unnecessary oil replacements and unplanned downtime with the regular use of our advanced purification system.
Built for compatibility and efficiency, our Double-Stage Vacuum Transformer Oil Purifier easily integrates with in-service transformers, bypass loops, and storage tanks. With a standard oil inlet/outlet diameter of ? 63 mm and a globally compatible power supply (AC380V/50Hz/3), it fits seamlessly into most industrial setups. The PLC-based control system allows synchronization with SCADA or DCS for real-time monitoring and control. It is crafted for plug-and-play deployment, the unit requires minimal retrofitting. This results in quicker installations and uninterrupted transformer maintenance operations.
Labtron’s Double-Stage Vacuum Transformer Oil Purifier significantly improves the dielectric strength of transformer oil by removing water, air bubbles, and particulate matter. These contaminants are responsible for lowering breakdown voltage and insulating capability. The unit ensures the oil is restored to a condition suitable for high-voltage applications by reducing moisture to less than 3 PPM and impurity size to less than 1 ?m. Our purification process stabilizes and enhances the oil’s insulation performance, directly contributing to the safe operation of power equipment.
Post your question?