Water and Air Chiller LRC-K10 offers a temperature range of -75°C to -40°C for optimal cooling. It features anti-surge functionality to handle fluctuating demands without performance loss. Its multi-point safety checks automatically adjust for system operation. The device includes dynamic fluid flow adjustments to adapt to varying requirements. Our chiller cools medical diagnostic equipment, ensuring reliable efficiency and preventing device failure during operation.

Request Quote
Temperature Range -75°C to -40°C
Temperature Control ±0. 5°C
Circulation Pump Flow Max 30L/min 1.6 BAR
Refrigerant R-448A/R23
Cooling Capacity at -60°C 0.7Kw
Cooling Capacity at -70°C 0.4Kw
Power AC 220V/ AC 380V/ AC 460V
  • Cryogenic Temperature Range 

  • Cooling for Analytical Instruments

  • Low-Emission Operation

  • Rapid Heat Removal

  • Automatic Defrost Capability

Our Water and Air Chiller cools components in medical diagnostic equipment, ensuring performance and preventing device failure. It also cools large-scale reactors in chemical manufacturing, maintaining optimal temperature reaction control.

Water and Air Chiller LRC-K10 | Circulation Pump Flow Max-30L/min 1.6 BAR | Refrigerant-R-448A/R23
Water and Air Chiller LRC-K10 | Cryogenic Temperature Range | Rapid Heat Removal

Models of Water And Air Chillers

Labtron Water and Air Chillers deliver precise thermal management for cooling processes and products across various industries. They provide regulation with accuracies ranging from ±0.1°C to ±0.5°C, depending on the specific model. Their systems feature energy-efficient compressors and pumps, reducing power use while ensuring optimal stabilization. These chillers include flow meters and sensors to monitor and adjust the circulation of water, ensuring reliability. Our chillers are ideal for applications requiring stable temperature control, such as in pharmaceuticals, lasers, and commercial sectors.

Water and Air Chiller LRC-G10

Water and Air Chiller LRC-G10

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-J11

Water and Air Chiller LRC-J11

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-I12

Water and Air Chiller LRC-I12

  • Temperature Range : -45°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-J13
Water and Air Chiller LRC-J13
  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-H12
Water and Air Chiller LRC-H12
  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-H11

Water and Air Chiller LRC-H11

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-H13

Water and Air Chiller LRC-H13

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-G11

Water and Air Chiller LRC-G11

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-K10 FAQ's
  • The chiller features a dynamic fluid flow system that adapts to rapid temperature changes, ensuring consistent and stable cooling performance. This capability is especially useful in environments where cooling demands can change suddenly, such as in industrial or medical applications. By adjusting the flow in real-time, the system maintains the desired temperature, preventing overheating or undercooling, and ensuring the protection of sensitive equipment.

  • Yes, it incorporates dynamic fluid flow adjustments to adapt to different system requirements seamlessly. The chiller continuously monitors the cooling needs of the system and makes real-time adjustments to optimize performance. This ensures that the cooling capacity is always aligned with the current demand, improving efficiency and reducing energy consumption. Whether the load increases or decreases, the chiller responds quickly to maintain consistent temperature control, making it ideal for applications with fluctuating cooling needs.

  • It features multi-point safety checks that automatically adjust operations to protect both the system and connected equipment. These checks monitor critical parameters such as pressure, temperature, and flow rate, ensuring that any irregularities are detected and corrected promptly. In the event of a potential issue, the system automatically triggers alerts or shuts down to prevent damage. This proactive safety mechanism helps extend the lifespan of the chiller and ensures the continued reliability of the equipment it cools.

  • It is ideal for cooling components in medical diagnostic equipment and large-scale reactors in chemical manufacturing. The chiller is also effective in research laboratories, where precise temperature control is crucial for experiments and equipment performance. Its versatility makes it suitable for cooling sensitive components in high-performance machinery and industrial processes, ensuring optimal operation across various industries. Whether in medical, chemical, or research settings, the chiller maintains reliable performance under demanding conditions.

  • The anti-surge feature protects the system from performance loss during fluctuating demands, ensuring stable and efficient operation. It actively monitors the system’s performance and adjusts to sudden changes in load, preventing potential damage or instability. This feature is particularly useful in environments with varying cooling requirements, such as medical or industrial applications. By maintaining a consistent cooling rate, the chiller enhances the longevity and reliability of both the unit and the equipment it supports.

  • The chiller offers a temperature range from -75°C to -40°C, ensuring optimal performance for various cooling applications. This wide range allows it to meet the cooling needs of sensitive components and large-scale systems. It is ideal for industries requiring precise temperature control, such as medical diagnostics and chemical manufacturing. The chiller maintains consistent performance even under demanding conditions, providing reliable and efficient cooling.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.