Request A Quote
Water and Air Chiller LRC-K11

Water and Air Chiller LRC-K11

Water and Air Chiller LRC-K11 offers a temperature control of ±0.5°C ensuring optimal thermal regulation. It features a powerful compressor for handling significant cooling loads during operation. Its responsive feedback system adjusts operation based on real-time data. The chiller ensures superior heat transfer for effective control in demanding environments. Our chiller is used for energy management in electrochemical systems, ensuring stability for accurate testing in laboratories.

Request Quote
Temperature Range -80°C to -40°C
Temperature Control ±0.5°C
Circulation Pump Flow Max 30L/min 1.6 BAR
Refrigerant R-448A/R23
Cooling Capacity at -60°C 1Kw
Cooling Capacity at -70°C 0.6Kw
Power AC 220V/ AC 380V/ AC 460V
  • Secure Temperature Control

  • Auto-Reset Function

  • Built-in Pressure Relief

  • High Heat Rejection Rate

  • Automated System Adjustments 

Our Water and Air Chiller cools reactors in pharmaceutical production processes, ensuring proper reaction rates and consistent output. It also cools electrochemical systems in laboratories, ensuring temperature stability for accurate testing.

Water and Air Chiller LRC-K11 | Refrigerant-R-448A/R23 | Cooling Capacity at -60°C-1Kw
Water and Air Chiller LRC-K11 | Secure Temperature Control | Auto-Reset Function

Models of Water And Air Chillers

Labtron Water and Air Chillers deliver precise thermal management for cooling processes and products across various industries. They provide regulation with accuracies ranging from ±0.1°C to ±0.5°C, depending on the specific model. Their systems feature energy-efficient compressors and pumps, reducing power use while ensuring optimal stabilization. These chillers include flow meters and sensors to monitor and adjust the circulation of water, ensuring reliability. Our chillers are ideal for applications requiring stable temperature control, such as in pharmaceuticals, lasers, and commercial sectors.

Water and Air Chiller LRC-J12

Water and Air Chiller LRC-J12

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-K12

Water and Air Chiller LRC-K12

  • Temperature Range : -80°C to -40°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-J11

Water and Air Chiller LRC-J11

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-J13
Water and Air Chiller LRC-J13
  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-G13
Water and Air Chiller LRC-G13
  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 50L/min 2bar
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-G11

Water and Air Chiller LRC-G11

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-K10

Water and Air Chiller LRC-K10

  • Temperature Range : -75°C to -40°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-I10

Water and Air Chiller LRC-I10

  • Temperature Range : -37°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-K11 FAQ's
  • The chiller is equipped with a built-in pressure relief system and multi-point safety checks to protect against system overpressure and operational faults. It continuously monitors parameters such as temperature, pressure, and fluid flow, automatically adjusting or shutting down the system if anomalies are detected. This proactive safety design ensures the longevity of the equipment and safeguards the stability of connected systems during critical operations.

  • Yes, the chiller includes an intuitive control system that makes operation straightforward. Its responsive feedback system ensures real-time adjustments for optimal performance. The user-friendly interface allows for quick setup and monitoring of key parameters, making it easy to maintain precise control. Additionally, the chiller's automated safety features and self-diagnostic capabilities enhance ease of use, minimizing the need for manual intervention during operation.

  • The chiller is equipped with a powerful compressor designed to handle large cooling demands during operation, ensuring consistent performance. Its advanced cooling technology allows it to maintain stable temperatures even under high-load conditions. The chiller’s efficient heat exchange system supports rapid cooling and quick recovery, preventing temperature fluctuations. This makes it ideal for applications where maintaining precise cooling is critical, such as in pharmaceutical production and electrochemical testing.

  • It is ideal for energy management in electrochemical systems, providing temperature stability for accurate testing in laboratories. It also cools reactors in pharmaceutical production, ensuring proper reaction rates and consistent output. The chiller is effective in maintaining optimal temperatures for sensitive equipment in research labs. Additionally, it is suitable for cooling systems in industrial processes that require precise temperature control, helping to improve operational efficiency and reliability.

  • The chiller features a responsive feedback system that adjusts operation based on real-time data, optimizing energy use and cooling efficiency. It also incorporates a variable frequency compressor, which adjusts its speed to match the cooling demands. This helps reduce energy consumption during low-demand periods. By continuously monitoring and adjusting to the system’s needs, the chiller ensures maximum energy savings without compromising performance.

  • The chiller offers a precise temperature control of ±0.5°C, ensuring optimal thermal regulation for various applications. This allows for stable operation in both laboratory and industrial environments. The chiller is capable of maintaining consistent temperatures even under varying load conditions. Its precise control is essential for energy management in sensitive systems such as electrochemical reactions and pharmaceutical production processes.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608