Request A Quote
Water and Air Chiller LRC-J11

Water and Air Chiller LRC-J11

Water and Air Chiller LRC-J11 offers temperature control accuracy of ±0.5°C for optimal cooling. It maintains low, stable temperatures ideal for preserving sensitive biological samples. The chiller uses low refrigerant consumption, reducing environmental impact and enhancing sustainability. Its smooth airflow system ensures uniform heat management, enhancing performance and preventing overheating during operations. Our chiller optimizes energy use and extends equipment life in veterinary clinics for efficient diagnostics and care.

Request Quote
Temperature Range -60°C to -30°C
Temperature Control ±0.5°C
Circulation Pump Flow Max 30L/min 1.6 BAR
Refrigerant R-448A/R23
Cooling Capacity at -40°C 1.8Kw
Cooling Capacity at -55°C 1Kw
Power AC 220V/ AC 380V/ AC 460V
  • Advanced Insulation Technology

  • Thermal Overload Protection

  • Heavy-Duty Industrial Cooling

  • High-Speed Fan Operation

  • Effective Condensation Management

Our Water and Air Chiller maintains stable conditions in veterinary clinics, ensuring controlled cooling for medical equipment. It provides precise temperature regulation for sensitive treatments, extending equipment life and guaranteeing effective diagnostics.

Water and Air Chiller LRC-J11 | Circulation Pump Flow Max-30L/min 1.6 BAR | Refrigerant-R-448A/R23
Water and Air Chiller LRC-J11 | Advanced Insulation Technology | High-Speed Fan Operation

Models of Water And Air Chillers

Labtron Water and Air Chillers deliver precise thermal management for cooling processes and products across various industries. They provide regulation with accuracies ranging from ±0.1°C to ±0.5°C, depending on the specific model. Their systems feature energy-efficient compressors and pumps, reducing power use while ensuring optimal stabilization. These chillers include flow meters and sensors to monitor and adjust the circulation of water, ensuring reliability. Our chillers are ideal for applications requiring stable temperature control, such as in pharmaceuticals, lasers, and commercial sectors.

Water and Air Chiller LRC-G13

Water and Air Chiller LRC-G13

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 50L/min 2bar
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-G12

Water and Air Chiller LRC-G12

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-J12

Water and Air Chiller LRC-J12

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-G11
Water and Air Chiller LRC-G11
  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-K12
Water and Air Chiller LRC-K12
  • Temperature Range : -80°C to -40°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-H12

Water and Air Chiller LRC-H12

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-I11

Water and Air Chiller LRC-I11

  • Temperature Range : -45°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-K10

Water and Air Chiller LRC-K10

  • Temperature Range : -75°C to -40°C
  • Temperature Control : ±0. 5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-J11 FAQ's
  • Yes, the chiller incorporates energy-efficient modes that reduce power consumption during idle periods, optimizing energy use without compromising performance. These modes help lower operational costs over time, making the chiller a sustainable choice for long-term use. Its smart temperature control system ensures minimal waste of resources while maintaining consistent performance. The reduced energy load also contributes to decreased environmental impact. This efficiency makes it suitable for continuous use in laboratories and clinics.

  • The chiller’s stable temperature control and efficient cooling system help reduce wear and tear on sensitive equipment, extending its lifespan and ensuring reliable performance for diagnostic applications. By maintaining consistent thermal conditions, it prevents frequent thermal cycling that can damage internal components. The smooth airflow system ensures even cooling, reducing strain on devices. This prolongs operational life and lowers maintenance needs. It ultimately supports consistent performance and cost-effective usage in veterinary and laboratory environments.

  • The chiller can also be used in other industries requiring precise temperature control, such as pharmaceuticals and chemical processing. Its robust construction and advanced cooling technology make it adaptable to diverse operational environments. The chiller supports stable processes in research labs, manufacturing lines, and analytical setups. Its versatility ensures consistent temperature management across various industrial applications.

  • Yes, the chiller is designed with easy-to-clean components and a reliable cooling system, ensuring minimal downtime and straightforward maintenance. Its modular structure allows quick access to internal parts for servicing. The system features intuitive controls and clear status indicators for simple monitoring. These user-friendly aspects help reduce maintenance effort and improve operational efficiency over time.

  • The chiller offers a temperature control accuracy of ±0.5°C, maintaining stable cooling conditions between -60°C to -30°C, making it ideal for sensitive applications in veterinary clinics and biotechnology research. Its wide temperature range supports diverse cooling needs, from preserving biological samples to regulating equipment temperatures. This flexibility ensures reliable performance across various demanding environments. The system is engineered to maintain consistency even during continuous operation.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.