Water and Air Chiller LRC-K12 offers a 1.4kW cooling capacity at -60°C and 0.85kW at -70°C for optimal thermal regulation. It incorporates a high-performance compressor for demanding environments. The device features intelligent heat control, adjusting cooling capacity based on real-time needs. Its internal load-balancing ensures that components are evenly distributed across all units for optimal cooling. Our chiller maintains energy efficiency and supports the storage and transport of pharmaceuticals and perishable goods, preserving quality and safety.

Request Quote
Temperature Range -80°C to -40°C
Temperature Control ±0.5°C
Circulation Pump Flow Max 30L/min 1.6 BAR
Refrigerant R-448A/R23
Cooling Capacity at -60°C 1.4Kw
Cooling Capacity at -70°C 0.85Kw
Power AC 220V/ AC 380V/ AC 460V
  • Long Service Life 

  • Overload Protection Feature

  • Industrial-Grade Temperature Control

  • Uniform Temperature Distribution

  • Minimal Maintenance Needs

Our Water and Air Chiller maintains low temperatures for pharmaceuticals and perishable goods, ensuring quality and safety during storage and transport, and stable cooling during processing, preserving product integrity.

Water and Air Chiller LRC-K12 | Circulation Pump Flow Max-30L/min 1.6 BAR | Refrigerant-R-448A/R23
Water and Air Chiller LRC-K12 | Long Service Life | Overload Protection Feature

Models of Water And Air Chillers

Labtron Water and Air Chillers deliver precise thermal management for cooling processes and products across various industries. They provide regulation with accuracies ranging from ±0.1°C to ±0.5°C, depending on the specific model. Their systems feature energy-efficient compressors and pumps, reducing power use while ensuring optimal stabilization. These chillers include flow meters and sensors to monitor and adjust the circulation of water, ensuring reliability. Our chillers are ideal for applications requiring stable temperature control, such as in pharmaceuticals, lasers, and commercial sectors.

Water and Air Chiller LRC-H12

Water and Air Chiller LRC-H12

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-G10

Water and Air Chiller LRC-G10

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-H10

Water and Air Chiller LRC-H10

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-J10
Water and Air Chiller LRC-J10
  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R23
Water and Air Chiller LRC-I13
Water and Air Chiller LRC-I13
  • Temperature Range : -45°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-G13

Water and Air Chiller LRC-G13

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 50L/min 2bar
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-H13

Water and Air Chiller LRC-H13

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6 BAR
  • Refrigerant : R-448A/R507C
Water and Air Chiller LRC-G11

Water and Air Chiller LRC-G11

  • Temperature Range : 10°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Flow Max : 30L/min 1.6BAR
  • Refrigerant : R-134A/R407C
Water and Air Chiller LRC-K12 FAQ's
  • Equipped with a high-performance compressor, the chiller efficiently handles significant cooling loads, ensuring stable operation even in demanding environments. The compressor adjusts its operation based on the cooling demand, maintaining optimal performance under varying conditions. Additionally, its advanced cooling technology allows for quick recovery, ensuring continuous, reliable cooling. This makes it ideal for applications with fluctuating or high cooling requirements.

  • The chiller is equipped with a high-performance compressor designed to excel in demanding environments, ensuring reliable cooling and energy efficiency. Its robust design allows it to handle significant cooling loads with minimal wear, extending the lifespan of the chiller. The compressor's efficiency is key to maintaining stable temperatures, even under fluctuating load conditions, and reducing energy consumption over time.

  • The chiller maintains consistent low temperatures, preserving the quality and safety of pharmaceuticals and perishable goods during storage and transport. Its precise temperature control prevents temperature fluctuations, which could compromise product integrity. The chiller’s reliable performance ensures that sensitive items remain within the required temperature range throughout the entire transport process. This minimizes the risk of spoilage or degradation, ensuring that pharmaceuticals and perishable goods arrive in optimal condition.

  • Yes, the chiller is equipped with load-balancing capabilities that ensure components are evenly distributed across all units for optimal performance. This feature helps prevent overloading of any single component, improving system efficiency and extending the lifespan of the chiller. It contributes to consistent performance, even under heavy or fluctuating cooling demands. The result is more reliable operation and better overall efficiency in various applications. Additionally, load-balancing helps in maintaining stable temperatures, reducing the risk of thermal fluctuations.

  • Yes, the chiller is ideal for laboratory use, particularly for applications requiring precise temperature control, such as electrochemical systems and sensitive testing environments. It ensures stable temperatures for accurate testing and reliable results. The chiller's advanced features, like intelligent heat control and load balancing, make it well-suited for laboratories with demanding cooling needs. Its energy efficiency also makes it a cost-effective solution for long-term laboratory use.

  • The chiller provides a cooling capacity of 1.4kW at -60°C and 0.85kW at -70°C, ensuring efficient cooling for various applications. It is designed for precise temperature control in demanding environments. The high cooling capacity ensures quick temperature stabilization and consistent performance. This makes it ideal for cooling sensitive systems such as pharmaceuticals and laboratory equipment. Its efficient operation helps reduce energy consumption while maintaining optimal performance.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.