CO Carbon Monoxide Gas Detector LCGD-D10 operates within a CO measuring range of 0 to 500 ppm. The high sensitivity allows early detection of carbon Monoxide, reducing the risk of poisoning. Its easy-to-read display shows CO concentration in real time, enabling quick decision-making. It provides continuous monitoring, ensuring prompt alerts to prevent hazardous exposure. ​Our detector is widely used in environments like commercial kitchens, chemical plants, power plants, tunnels, agricultural facilities, residential areas to prevent CO poisoning.

CO Carbon Monoxide Gas Detector LCGD-D10
CO Carbon Monoxide Gas Detector LCGD-D10
Request Quote
Measured Parameters CO, Temperature, Humidity
Temperature Range -10°C to 50°C
Storage Temperature -10°C to 60°C
Relative Humidity 20% to 85%
Humidity Range 20% to 85%
Atmospheric Pressure 12.5 to 15.4 PSI
Detection Method (CO) Electrochemistry
CO Measuring Range 0 to 500 ppm
Sampling Time 1.5 Seconds
Power Supply 800 mAh
Dimensions 70 × 70 × 28 mm
Weight 81g
  • Continuous safety protection 

  • Multiple application versatility

  • Efficient power usage
  • Enhanced safety performance

  • Versatile installation options

Our CO Carbon Monoxide Gas Detector is widely used in commercial kitchens, chemical plants, tunnels, agricultural facilities and residential areas helping prevent CO poisoning and ensuring safe working conditions.

Type-C Charge Cabel

CO Carbon Monoxide Gas Detector LCGD-D10 | Measured Parameters CO, Temperature, Humidity | Relative Humidity	20% to 85%
CO Carbon Monoxide Gas Detector LCGD-D10 | Continuous safety protection | Multiple application versatility

Models of Gas Detectors

Labtron Gas Detectors delivers multi gas detectors in 4-in-1, 10-in-1 and 2-in-1 types for real-time gas monitoring with light and audible alerts. Our gas detector device is available as wall mounted, handheld or portable units with built-in sample pumps and data transfer for storage, including infrared, nitrogen, helium or methane detectors. This digital gas detector selection suits gas monitoring in industrial work areas and laboratories, with single gas detector units for carbon monoxide, ammonia or chlorine.

Portable Multiple Gas Detector LPMG-A11

Portable Multiple Gas Detector LPMG-A11

  • Gas Detected : O₂, LEL, CO, H₂S, SO₂, C₁₂, NH₃, NO₂, NO, O₃, PH₃, H₂, HF, HCl, HCN, CH₄ (IR), PID (VOCs), CO₂ (IR), C₃H₈ (IR), C₂H₄ (Choose any 5)
  • Measuring Range : O₂: 0-25% vol / 30% vol, LEL: 0-100% LEL, CO: 0-1000 ppm / 2000 ppm, H₂S: 0-200 ppm, 0-100% LEL, SO₂: 0-200 ppm, C₁₂: 0-20 ppm, NH₃: 0-100 ppm / 2000 ppm, NO₂: 0-200 ppm, NO: 0-1000 ppm, O₃: 0-5% vol, 0-5 ppm / 20 ppm, PH₃: 0-10 ppm, H₂: 0-2000 ppm / 4% vol, HF: 0-10 ppm, HCl: 0-30 ppm / 200 ppm, HCN: 0-200 ppm, CH₄ (IR): 0-5.00% vol, 0-1000 ppm, PID (VOCs): 0-1999.9 ppm, CO₂ (IR): 0-5.00% vol, (0-1% vol), 0-100 ppm, C₃H₈ (IR): 0-100 ppm, C₂H₄: 0-100 ppm (Choose any 5)
  • Measuring Resolution : O₂: 0.1% vol, LEL: 1% LEL, CO: 1 ppm, H₂S: 0.1 ppm, SO₂: 0.1 ppm, C₁₂: 0.1 ppm, NH₃: 1 ppm, NO₂: 0.1 ppm, NO: 1 ppm, O₃: 0.1 ppm, PH₃: 0.1 ppm, H₂: 1 ppm, HF: 0.1 ppm, HCl: 0.1 ppm, HCN: 0.1 ppm, CH₄ (IR): 0.01% vol, PID (VOCs): 0.1 ppm, CO₂ (IR): 0.01% vol, C₃H₈ (IR): 0.01% vol, C₂H₄: 0.1 ppm (Choose any 5)
  • Detecting Method : Diffusion or Pump
Portable 4 In 1 Multi Gas Detector LPGD-A12

Portable 4 In 1 Multi Gas Detector LPGD-A12

  • Gas Detected : PH₃, CH₃Br, CO₂, Other gas combinations
  • Measuring Range : PH₃: 0 to100 ppm, CH₃Br: 0 to 100 ppm, CO₂: 0 to 5000 ppm
  • Sampling Method : Natural diffusion
  • Display Mode : LCD screen
Portable Nitrous Oxide Gas Detector LPNG-A11

Portable Nitrous Oxide Gas Detector LPNG-A11

  • Detected Gases : Oxygen (O₂), Combustible gases (EX), Toxic gases (CO, H₂S, NH₃, Cl₂, etc.)
  • Measuring Range : 0 to 20,000 ppm
  • Measuring resolution : Around 1 ppm
  • Response Time : ≤ 30 s (O₂), ≤ 40 s (CO), ≤ 20 s (EX)
Portable 2 In 1 Gas Detector LPTG-A10
Portable 2 In 1 Gas Detector LPTG-A10
  • Gas detected : CO₂ and O₂, CO, NH₃, or H₂S
  • Measuring Range : CO₂: 0% to 5% vol, O₂: 5% to 25% vol, CO: 0 to 1000 ppm, NH₃: 0 to 30% vol, H₂S: 0 to 100 ppm
  • Measuring Resolution : CO₂: 0.01%; O₂: 0.1%
  • Sampling Method : Diffusion
Portable 2 In 1 Gas Detector LPTG-A11
Portable 2 In 1 Gas Detector LPTG-A11
  • Gas Detection : SO₂ and CO
  • Measuring Range : SO₂: 0 to1000, CO: 0 to 10,000 PPM
  • Measuring Resolution : SO₂: 0.001 PPM, CO: 0.001 PPM
  • Sampling Method : Built-in pump
CO Carbon Monoxide Gas Detector LCGD-D11

CO Carbon Monoxide Gas Detector LCGD-D11

  • Measured Parameters : CO, Temperature, Humidity
  • Temperature Range : -10°C to 50°C
  • Storage Temperature : -10°C to 60°C
  • Relative Humidity : 20% to 85%
Handheld C2H4 Ethylene Gas Detector LEGD-A10

Handheld C2H4 Ethylene Gas Detector LEGD-A10

  • Gas Detected : Ethylene (C₂H₄)
  • Measuring Range : 0 to 1000 ppm
  • Measuring Resolution : 1 ppm
  • Precision : 3 to 10% Full Scale (F.S.)
Portable 4 In 1 Multi Gas Detector LPGD-A11

Portable 4 In 1 Multi Gas Detector LPGD-A11

  • Gas Detected : Combustible Gas, Oxygen (O₂), Carbon Monoxide (CO), Hydrogen Sulfide (H₂S)
  • Measuring Range : Combustible Gas: 0 to 100,000 ppm, Oxygen (O₂): 0 to 300,000 ppm, Carbon Monoxide (CO): 0 to 1,000 ppm, Hydrogen Sulfide (H₂S): 0 to 100 ppm
  • Measuring Resolution : Combustible Gas (Ex): 0.1% LEL, O₂: 0.01% vol, CO: 1 ppm; H₂S: 0.1 ppm
  • Detection Principle : Catalytic for combustibles; Electrochemical for toxic gases
CO Carbon Monoxide Gas Detector LCGD-D10 FAQ's
  • The LCGD-D10 is widely used in commercial kitchens, chemical plants, power plants, tunnels, agricultural facilities, and residential areas. It is ideal for environments where carbon Monoxide risks are high and early detection is crucial to ensure safety. The detector is suitable for both industrial and residential applications, providing reliable protection in various settings.

  • The CO Carbon Monoxide Gas Detector continuously monitors the air for carbon Monoxide (CO) levels, providing real-time readings on its display. It uses advanced sensor technology to detect even low levels of CO, ensuring early detection. When CO concentrations exceed a pre-set safe threshold, the detector activates both audible and visual alarms to alert users.

  • The LCGD-D10 features both an audible and visual alarm system that alerts users when CO levels become hazardous. The audible alarm emits a loud sound, ensuring it can be heard even in noisy environments, while the visual alarm uses flashing lights to provide a clear, attention-grabbing signal. The alarms are activated when CO concentrations exceed a predefined safety threshold, prompting immediate action to prevent exposure.

  • Yes, the LCGD-D10 is suitable for both indoor and outdoor use, thanks to its durable and weather-resistant design. It is built to withstand harsh environmental conditions such as rain, humidity, and temperature fluctuations, making it ideal for use in outdoor settings like construction sites, agricultural facilities, and industrial areas. Its robust construction ensures reliable performance, providing continuous protection against carbon Monoxide exposure.

  • To maintain the LCGD-D10 Carbon Monoxide Detector, regularly check the battery level to ensure its fully charged or replace it when needed. Clean the device periodically, using a dry cloth to wipe away dust and debris. Test the detector monthly to confirm its operating correctly and that the alarm sounds at the appropriate thresholds. Ensure the sensor is not obstructed and is functioning properly.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.