Request A Quote
High And Low Temperature Circulator LHLTC-A18

High And Low Temperature Circulator LHLTC-A18

High and Low Temperature Circulator LHLTC-A18 offers a –30°C to 200°C range and supports dynamic control in sensitive processes. It features an external sensor port for feedback-based temperature regulation during real-time thermal adjustments and system monitoring. The compact brazed plate heat exchanger ensures fast and efficient thermal transfer. Our circulator is used for protein lines, fermentation systems and pharmaceutical pilot processes.

High and Low Temperature Circulator LHLTC-A18
High and Low Temperature Circulator LHLTC-A18
Request Quote
Working Temperature Range -30 to 200°C
Ambient Temperature 5 to 35°C
Relative Humidity Less than or equal to 70%
Temperature Control Accuracy ±1°
Temperature Sensor PT100
Circulating Pump Pressure Less than or equal to 0.4 MPa
Circulating Pump Lift 4 to 6 m
Max. Reactor Volume Can Be Matched 20 L
External Input External Sensor Port
Cooling Capacity 4648 W
Heating Power 3000 W
Compressor Power 1470 W
Circulating Pump Power 100 W
Power Consumption 4570 W
Power Supply Single Phase 220V / 50Hz
Dimensions (W × D × H) 630 × 670 × 990 mm
Net Weight 104 kg
  • Top-facing control panel

  • Rear service access hatch

  • Anti-corrosive outer housing

  • Ground-fault protected wiring

  • Stable caster wheelbase

High and Low Temperature Circulator LHTC-A18 delivers external heating and cooling for temperature-sensitive systems. This supports stable control in reactors, bioreactors, and pilot-scale processing units.

Models of High and Low Temperature Circulator

Labtron High and Low Temperature Circulator operates across a wide temperature range suitable for controlled heating and cooling tasks. They feature a control system that ensures stable performance under thermal variations. Their circulation system delivers uniform fluid flow for consistent temperature. These units use optimized compressor power with protections like over-temperature cut-off and delay. Our High and Low Temperature Circulator supports bio-fermentation tanks extraction units beverage lines and semiconductor cooling setups.

High And Low Temperature Circulator LHLTC-A15

High And Low Temperature Circulator LHLTC-A15

  • Working Temperature Range : -40 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A16

High And Low Temperature Circulator LHLTC-A16

  • Working Temperature Range : -80 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A20

High And Low Temperature Circulator LHLTC-A20

  • Working Temperature Range : -40 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A17
High And Low Temperature Circulator LHLTC-A17
  • Working Temperature Range : -80 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A13
High And Low Temperature Circulator LHLTC-A13
  • Working Temperature Range : -30 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A11

High And Low Temperature Circulator LHLTC-A11

  • Working Temperature Range : -20 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A14

High And Low Temperature Circulator LHLTC-A14

  • Working Temperature Range : -40 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A21

High And Low Temperature Circulator LHLTC-A21

  • Working Temperature Range : -40 to 200°C
  • Ambient Temperature : 5 to 35°C
  • Relative Humidity : Less than or equal to 70%
  • Temperature Control Accuracy : ±1°
High And Low Temperature Circulator LHLTC-A18 FAQ's
  • Our High and Low Temperature Circulator LHLTC-A18 is well-suited for processes that involve sudden heat generation or absorption due to its fast-responding thermal adjustment capability. It integrates heating and cooling within the same system, allowing quick transition between temperatures. The internal structure is designed to adapt rapidly to energy shifts without destabilizing the material environment. Its fluid circulation mechanism remains steady even under fluctuating thermal loads. The system doesn’t rely on external adjustments to handle abrupt changes. This makes it compatible with highly reactive setups. No auxiliary cooling unit is needed during fast exothermic reactions. The circulator stays efficient during continuous load cycling without overcompensation.

  • The High and Low Temperature Circulator LHLTC-A18 is frequently used in fermentation lines because of its ability to maintain thermal balance throughout extended runs. Its performance remains stable even when subjected to biologically active environments that release or consume heat at irregular intervals. The device uses responsive thermal exchange to maintain the culture’s required temperature range. Bio-fermentation tanks connected to the unit benefit from the consistency in temperature, which supports yield accuracy. The system helps to limit contamination risks that might occur with fluctuating temperatures. Overheating and heat loss during the process are kept in check without the need for human intervention. Long-duration operation is supported without drift in output. This capability ensures scalability for research and pilot lines alike.

  • Labtron’s High and Low Temperature Circulator LHLTC-A18 can be integrated with extraction units due to its steady thermal delivery and recovery features. During concentration, temperatures often shift based on solvent evaporation, and this circulator adapts without instability. The unit supports uniform heat transfer across varying contact surfaces involved in extraction systems. Whether it’s herbal extraction or concentration of volatile components, this model can handle temperature demands without causing process delays. It also minimizes temperature lag that typically impacts concentration output. The device can be connected without requiring layout changes. It offers extended temperature support to keep extract integrity intact. This makes it suitable for both botanical and pharmaceutical extraction workflows.

  • The High and Low Temperature Circulator LHLTC-A18 has been built to support installations where space is limited but thermal performance cannot be compromised. It operates without demanding extra space for auxiliary components and can be paired directly with small-scale pilot tanks. Its design eliminates the need for reconfiguration of lab or production layouts. The circulator fits easily alongside benches, control stations, and compact reaction systems. Its portability allows relocation when pilot setups are moved or scaled. Despite its compact footprint, it offers a complete heating and cooling package. The machine can serve as a standalone temperature control unit in modular environments. This adaptability makes it suitable for diverse R&D stations.

  • Labtron’s High and Low Temperature Circulator LHLTC-A18 is equipped with multiple built-in safeguards that allow continuous use without risking component failure. The system includes protection functions designed to act in case of temperature overloads, fluid level drops, or electrical surges. These safety features work in coordination rather than as isolated alerts. Its control system allows real-time fault detection before errors escalate. Fluid leaks are prevented through internal sealing strategies rather than external valves. Users are alerted early to unusual load patterns. The unit’s design avoids unplanned shutdowns during high-load cycles. This makes it suitable for critical setups where unattended operation is frequent.

  • The High and Low Temperature Circulator LHLTC-A18 is commonly paired with devices such as calorimeters, pilot mixers, or UV cooling units where stable fluid temperature ensures device accuracy. These tools require exact temperatures over long durations without deviation. The circulator ensures constant flow rate and minimal heat fluctuation even under load variance. The heat transfer fluid remains stable even when heat input from external sources changes. It does not require separate thermal controllers to handle feedback from sensitive instruments. Flow consistency is maintained using controlled pumping pressure. The circulator can handle both static and moving temperature targets. This flexibility helps maintain repeatable results across sensitive equipment.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.