Request A Quote
High Purity Water System LHPW-A21

High Purity Water System LHPW-A21

High Purity Water System LHPW-A21 operates using tap water with a conductivity of less than 400 µS/cm at 25°C. It features a quiet, stable high-pressure pump for efficient operation. It offers an optional remote monitoring and management system. It features a dual-system backup mechanism for enhanced reliability and continuous supply of pure water. Our High Purity Water System is ideal for reagent and buffer preparation, media formulation, sample dilution, and glassware rinsing.

Request Quote
Source Tap Water
Conductivity (25 ºC) < 400 us/cm
Water Temperature 5 ºC to 40 ºC
Water Pressure 0.1 to 0.4 MPa
Inlet Water Tube Diameter 3/4 inch
RO Desalination Rate ≥ 98%
RO2 Desalination Rate ≥ 99%
Microbial Removal Rate ≥ 99%
Productivity Rate (25 ºC) 500 L/h
Water Quality (25 ºC) ≥ 10 MΩ.cm
Power Supply AC 220 V / 2.0 KW
Dimension (Pretreatment Unit) 950 × 750 × 1850 mm
Dimension (Main Unit) 1040 × 800 × 1920 mm
  • Green Mode Operation

  • Chemical-Free Operation

  • Dual Dispensing Options

  • Emergency Stop Function

  • Low Water Level Alarm

Our High Purity Water System is ideal for preparing chemical solutions, culture media, and reagents, eliminating interference from ions, particulates, or organic contaminants to ensure reliable experimental results.

Accessories

Quantity

Unit

Raw water tank

1

Set

Raw water pump

1

Set

Sand filter

1

Unit

Activated carbon filter

1

Unit

Water softener

1

Unit

Brine box

1

Set

Precision (security) filter

1

Set

Pretreatment rack

1

Set

High-pressure pump

1

Set

Reverse osmosis column

2

Pieces

Water treatment measurement and control

1

Set

EDI membrane stack

1

Set

EDI power supply

1

Set

Combined electric control box

1

Set

UPVC pipe valve parts

1

Set

Rack

1

Set

Pure water tank

1

Set

Precision filter

1

Set

UV disinfection sterilizer

1

Set

Pure water supply pump

1

Set

Accessories 

Quantity

Unit

Activated carbon

1 

Bag

Softening resin

1 

Bag

Softening salt

1 

Bag

Security filter element

1 

Package

Precision filter element

1 

Package

Air filter for water tank

1 

Piece

Reverse osmosis membrane element 

1 

Piece

Reverse osmosis membrane

1 

Piece

Imported precision resin

1 

Package

Imported nuclear grade resin

1 

Package

150L EDI module

1 

Piece

250L EDI module

1 

Piece

450L EDI module

1 

Piece

High Purity Water System LHPW-A21 | Conductivity (25 ºC): < 400 us/cm | Water Temperature: 5 ºC to 40 ºC
High Purity Water System LHPW-A21 | Green Mode Operation | Chemical-Free Operation

Models of High Purity Water System

Labtron High Purity Water Systems are built to deliver consistently high-purity water using advanced technologies such as reverse osmosis, deionization, electrodeionization, and ultrafiltration. These systems produce water with resistivity up to 18.2 MΩ·cm, TOC below 5 ppb, and minimal microbial or particulate content. They incorporate advanced features like real-time monitoring, auto-flushing, and RFID tracking. These systems ensure durable, leak-free construction for long-term reliability. Our High Purity Water Systems are ideal for media preparation, microbiological analysis, and general chemistry, ensuring consistently contaminant-free results.

High Purity Water System LHPW-A12

High Purity Water System LHPW-A12

  • RO Production Rate : 100 L/h
  • Water Tank Capacity : 60 L
  • Source : Tap Water
  • Conductivity : < 2000 us/cm
High Purity Water System LHPW-A11

High Purity Water System LHPW-A11

  • Water Yield : 150 L/h
  • Feed Water : Urban tap water
  • Feed Water TDS : < 200 ppm
  • Inlet Pressure : 0.15–0.4 MPa
High Purity Water System LHPW-A22

High Purity Water System LHPW-A22

  • Source : Tap Water
  • Conductivity (25 ºC) : < 400 us/cm
  • Water Temperature : 5 ºC to 40 ºC
  • Water Pressure : 0.1 to 0.4 MPa
High Purity Water System LHPW-B10
High Purity Water System LHPW-B10
  • Model Type : Bench top
  • Source Water : Tap Water
  • Feed Water Conductivity : < 2000 µs/cm
  • Feed Water Hardness : < 450 ppm as CaCO3
High Purity Water System LHPW-A20
High Purity Water System LHPW-A20
  • Source : Tap Water
  • Conductivity (25 ºC) : < 400 us/cm
  • Water Temperature : 5 ºC to 40 ºC
  • Water Pressure : 0.1 to 0.4 MPa
High Purity Water System LHPW-A10

High Purity Water System LHPW-A10

  • RO Production Rate : 100 L/h
  • Water Tank Capacity : 60 L
  • Source : Tap Water
  • Conductivity : < 2000 us/cm
High Purity Water System LHPW-A13

High Purity Water System LHPW-A13

  • RO Production Rate : 150 L/h
  • Water Tank Capacity : 350 L
  • Source : Tap Water
  • Conductivity : < 2000 us/cm
High Purity Water System LHPW-A23

High Purity Water System LHPW-A23

  • Source : Tap Water
  • Conductivity (25 ºC) : < 400 us/cm
  • Water Temperature : 5 to 40 ºC
  • Water Pressure : 0.1 to 0.4 MPa
High Purity Water System LHPW-A21 FAQ's
  • Unlike basic reverse osmosis systems, the High Purity Water System LHPW-A21 combines RO with electrodeionization (EDI), offering a more advanced level of purification without the need for chemical-based resin regeneration. EDI continuously polishes the RO-permeate water to deliver stable, high-purity output suitable for demanding applications. The system also features a real-time digital display, intelligent alarms, and consumable life tracking, which are typically absent in standard RO units. Additionally, its low cell constant resistivity meter ensures precise measurement of water quality, which is crucial for research and analytical labs. The modular design and multiple operation modes also provide a level of flexibility and control not commonly found in conventional systems. These enhancements make the HydroMax-E-3 High Purity Water System LHPW-A21 a superior choice for laboratories that need both reliability and advanced features.

  • The High Purity Water System LHPW-A21 is designed with energy efficiency, incorporating a high-performance RO membrane that minimizes energy consumption during water purification. Its anti-scaling EDI module operates without the need for chemical regeneration, which reduces both energy and resource usage. The intelligent control system ensures the unit only runs when needed, conserving electricity during idle periods. Real-time monitoring allows users to track operational parameters and optimize performance for reduced power draw. Additionally, the system supports recirculation modes that prevent water wastage and help maintain purity without constant operation. Overall, it offers an efficient solution for labs aiming to reduce operating costs and environmental impact.

  • The main consumables in the High Purity Water System LHPW-A21 include pre-treatment filters, RO membranes, and internal cartridges supporting the EDI process. The pre-treatment filters typically include sediment and activated carbon filters, which protect downstream components by removing chlorine, particulates, and other contaminants. Depending on feed water quality and usage, these filters may need to be replaced every 3–6 months. The RO membrane has a longer life span, often lasting 12–24 months, while the EDI module is designed to last significantly longer due to its anti-scaling and self-regenerating properties. The system’s built-in consumable life indicators help users track usage and receive timely alerts, making maintenance predictable and efficient.

  • Yes, the High Purity Water System LHPW-A21 is designed for seamless integration with a wide range of laboratory equipment. It can directly supply high purity water to instruments like AAS, FAAS, ELISA readers, pH meters, and hydrogen generators. The system features standard water outlet fittings that can connect to lab pipelines, storage tanks, or direct-feed devices. Its compact and modular design allows for installation on benchtops or under lab counters, maximizing space efficiency. Additionally, it supports both continuous and intermittent water supply modes, making it adaptable to the workflow demands of different lab setups. This level of flexibility makes it an excellent choice for laboratories upgrading or expanding their water purification infrastructure.

  • The High Purity Water System LHPW-A21 is equipped with several safety features to protect both the system and its users. It includes automatic pressure protection to shut down or alert users in case of abnormal feed water pressure, preventing damage to internal components. The system has built-in alerts for high or low conductivity, temperature fluctuations, and component malfunctions. Leak detection sensors and fault alarms ensure prompt notification of operational issues, minimizing downtime and potential damage. The display panel provides clear status indicators and error messages for quick troubleshooting. These safeguards contribute to operational safety and help maintain consistent water quality under all working conditions.

  • A high purity water system is a compact, advanced unit designed to purify water to extremely low levels of contaminants. It removes ions, organic compounds, particles, and microorganisms to produce ultra-clean water. This level of purification is essential in laboratory, pharmaceutical, and analytical environments where accuracy is critical. The system ensures consistent water quality for reproducible results. It is typically designed for benchtop or wall-mounted installation. Simple operation and low maintenance make it ideal for daily laboratory use.

  • A high purity water system typically combines multiple purification methods to achieve optimal water quality. These include reverse osmosis (RO) to remove dissolved salts and large molecules, deionization (DI) for ion removal, electrodeionization (EDI) for continuous ion exchange, and ultrafiltration (UF) to eliminate particulates and microorganisms. Each stage targets specific contaminants to ensure a thorough multi-step purification process. Additional technologies like UV sterilization or TOC reduction may be included based on application needs. The result is highly purified water suitable for a wide range of laboratory procedures.

  • Yes, the high purity water system is designed with energy and resource efficiency. Automatic flushing cycles help reduce water waste and prolong membrane life. It often includes recyclable filter housings and durable components to minimize environmental impact. Reject water can be repurposed for non-critical tasks such as equipment cleaning or cooling. Energy-efficient pumps help lower electricity consumption during operation. These features support sustainable practices and help reduce long-term operating costs.

  • Automatic flushing prevents the accumulation of contaminants on filters and membranes by periodically rinsing the internal components. This process helps maintain membrane efficiency and consistent water purity. It also minimizes the risk of microbial growth during idle periods. Flushing extends the lifespan of consumables and reduces maintenance needs. The timing and frequency of flushing can usually be adjusted according to usage. It is a key feature that ensures system reliability and stable water quality over time.

  • Yes, a high purity water system is designed for continuous or high-frequency use in demanding laboratory environments. It features automated controls that maintain stable operation during prolonged use. The system regulates flow and pressure to ensure uninterrupted output. Sensors constantly monitor water quality to prevent fluctuations. Automatic flushing and scheduled maintenance cycles help prevent fouling and microbial buildup. When properly maintained, the system can deliver consistently high-quality water throughout extended operation.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608