| Drying Area | 8 or 16 tubes |
| No-load Temperature | Min.to Less than or Equal - 102℃ (cold trap) |
| Cold Trap Volume | 27 Liters |
| Ice Holding Capacity | 15 Kg |
| 24-hour Maximum Ice Holding Capacity | 5 Kg |
| No-load Vacuum Pressure | 5 Pa |
| Ultimate Vacuum | 1Pa |
| Material Tray Diameter | Ø 280 mm |
| Shelf Spacing | 60 mm(can be removed and adjusted) |
| Compressor | Two interconnected compressors, with one responsible for refrigerating the other. |
| Tray-loaded Solution | 2.5 Liters |
| Installed Capacity | 2.8 Kw (220V 50Hz) |
| Operating Noise | ≤ 60dB |
| Ambient Temperature | Less than or Equal to 26℃ |
| Dimension | 700 × 700 × 870 mm |
| Weight | 160 Kg |
Bench-top T-type Freeze Dryer LBFD-B17 is widely used in laboratories, pharmaceuticals, and biotechnology for preserving heat and moisture-sensitive materials.
Download catalog for
Bench-top T-type Freeze Dryer LBFD-B17 Catalog
Available Range :
Bench-top Top Press Freeze Dryer LBFD-C13 : 0.08 ㎡ Bench-top Standard Freeze Dryer LBFD-A18 : 0.09 ㎡ Bench-top Manifold Freeze Dryer LBFD-D16 : 0.09 ㎡ plus 10 tubes Bench-top Standard Freeze Dryer LBFD-A19 : 0.12 ㎡ Bench-top Manifold Freeze Dryer LBFD-D17 : 0.12 ㎡ plus 10 tubes Bench-top Standard Freeze Dryer LBFD-A23 : 0.18 ㎡ Bench-top Standard Freeze Dryer LBFD-A24 : 0.25㎡ Bench-top T-type Freeze Dryer LBFD-B13 : 8 or 16 tubesLabtron Laboratory Bench-top Freeze Dryer offers compact, desktop-sized unit of temperature ranging from -50℃ to -100℃. Their moisture sensors provide accurate readings, ensuring correct monitoring throughout cycle. They offer automatic defrosting capabilities, reducing manual intervention and ensuring consistent freeze-drying efficiency. Their safety interlocks prevent accidental operation, enhancing user safety during process. Our Laboratory Bench-top Freeze Dryer is ideal for preserving sensitive biological materials like enzymes, proteins, tissues, pharmaceuticals and food samples.








Our Labtron Bench-top T-type Freeze Dryer is specially designed to preserve heat and moisture-sensitive materials by using a freeze-drying process that removes moisture without exposing the material to high temperatures. This ensures the integrity and stability of delicate samples such as pharmaceuticals and biological products. The system’s cold trap can reach temperatures as low as -102?, which efficiently freezes the samples. Additionally, the vacuum pressure system helps to remove ice by sublimation, preventing damage to the samples during drying. Its stainless-steel top surface also resists corrosion, which keeps the environment clean and contamination-free.
The vacuum system in the Labtron freeze dryer automatically monitors the vacuum pressure during operation. If the vacuum pressure does not reach the preset level within a specified time, the system will automatically shut down the vacuum pump. This safety feature prevents damage to the pump and ensures that the freeze-drying process proceeds efficiently. The device also achieves an ultimate vacuum pressure as low as 1 Pa, which is essential for effective freeze-drying, as it helps to remove moisture without applying heat that could degrade sensitive materials.
Our Labtron Bench-top T-type Freeze Dryer offers several user-friendly features that simplify operation and data management in a lab setting. It includes a colour touch screen that provides easy control and monitoring of the freeze-drying process. The circular round screen design allows clear visibility of the drying tubes. The machine also includes USB ports, making it easy to access and transfer data for record-keeping or further analysis. Additionally, it operates quietly with low vibration and noise (under 60 dB), ensuring a comfortable environment in the laboratory.
Our Labtron Bench-top T-type Freeze Dryer has two options for drying area: 8 or 16 tubes, each with a tray diameter of 280 mm and adjustable tray spacing of 60 mm. It has a cold trap volume of 27 Liters and an ice holding capacity of 15 kg, with a maximum ice capacity of 5 kg within 24 hours. The system’s dimensions are 700 mm by 700 mm by 870 mm, and it weighs 160 kg. Its installed power capacity is 2.8 kW, designed to operate efficiently in environments with ambient temperatures up to 26?.
Labtron Bench-top T-type Freeze Dryer is widely used in laboratories, pharmaceutical manufacturing, and biotechnology industries. It is particularly valuable for preserving heat and moisture-sensitive materials, such as biological samples, vaccines, enzymes, and pharmaceutical compounds. By freeze-drying these materials, it helps extend their shelf life, maintain potency, and facilitate storage and transportation without the need for refrigeration. This makes it a crucial tool in research and production environments where maintaining the quality of sensitive substances is essential.