Request A Quote
Bench-top Manifold Freeze Dryer LBFD-D16

Bench-top Manifold Freeze Dryer LBFD-D16

Bench-top Manifold Freeze Dryer LBFD-D16 features a 0.09 ㎡ drying area and 4 Kg ice holding capacity. Our Bench-top Manifold Freeze Dryer has a high-power condenser and control system accurately monitors both the material and machine status in real time. A PID controller ensures precise temperature control with shelves coated in advanced aerospace-grade heating film. It also tracks vacuum pump running hours to help schedule timely oil changes. It is used in laboratory-scale freeze-drying, pharmaceuticals, and biotechnology for preserving heat and moisture-sensitive materials.

Request Quote
Drying Area 0.09 ㎡ plus 10 tubes
No-load Temperature Min.to Less than or Equal -60℃ (cold trap)
Cold Trap Volume 6 Liters
Ice Holding Capacity 4 Kg
24-hour Maximum Ice Holding Capacity 2 Kg
No-load Vacuum Pressure 5 Pa
Ultimate Vacuum 1Pa
Number Of Shelves 3 Layers
Material Tray Diameter Ø 200 mm
Shelf Spacing 60 mm
Tray-loaded Solution 0.9 Liters
Installed Capacity 1Kw (220V 50Hz)
Operating Noise ≤55dB
Ambient Temperature Less than or Equal to 26℃
Dimension 520 × 480 × 460 mm
Weight 55 Kg
  • Hermetic compressor
  • Stainless steel 304
  • Curved integrated structure
  • Internal condenser coils
  • Thermal overload protection

Bench-top Manifold Freeze Dryer LBFD-D16 is widely used in laboratories, pharmaceuticals, and biotechnology for preserving heat and moisture-sensitive materials.

  • Two-stage rotary vane vacuum pump
  • 10 Series Multi Manifold Racks (16 Heads)
  • 10 Series Capping Devices

Models of Laboratory Bench-top Freeze Dryer

Labtron Laboratory Bench-top Freeze Dryer offers compact, desktop-sized unit of temperature ranging from -50℃ to -100℃. Their moisture sensors provide accurate readings, ensuring correct monitoring throughout cycle. They offer automatic defrosting capabilities, reducing manual intervention and ensuring consistent freeze-drying efficiency. Their safety interlocks prevent accidental operation, enhancing user safety during process. Our Laboratory Bench-top Freeze Dryer is ideal for preserving sensitive biological materials like enzymes, proteins, tissues, pharmaceuticals and food samples.

Bench-top T-type Freeze Dryer LBFD-B13

Bench-top T-type Freeze Dryer LBFD-B13

  • Drying Area : 8 or 16 tubes
  • No-load Temperature : Min.to Less than or Equal -68℃ (cold trap)
  • Cold Trap Volume : 13 Liters
  • Ice Holding Capacity : 6 Kg
Bench-top Standard Freeze Dryer LBFD-A21

Bench-top Standard Freeze Dryer LBFD-A21

  • Drying Area : 0.12 ㎡
  • No-load Temperature : Min.to Less than or Equal - 102℃ (cold trap)
  • Cold Trap Volume : 13 Liters
  • Ice Holding Capacity : 6 Kg
Bench-top Manifold Freeze Dryer LBFD-D14

Bench-top Manifold Freeze Dryer LBFD-D14

  • Condenser Temperature : - 90℃
  • Condenser Capacity : 6 kg
  • Cold Trap Volume : 10 L
  • Freeze-Dried Chamber Type : Acrylic chamber with aluminum upper cover and external valve (12 ports)
Bench-top Manifold Freeze Dryer LBFD-D18
Bench-top Manifold Freeze Dryer LBFD-D18
  • Drying Area : 0.12 ㎡ plus 10 tubes
  • No-load Temperature : Min.to Less than or Equal -102℃ (cold trap)
  • Cold Trap Volume : 13 Liters
  • Ice Holding Capacity : 6 Kg
Bench-top T-Type Freeze Dryer LBFD-B18
Bench-top T-Type Freeze Dryer LBFD-B18
  • Ice Condenser Capacity : 3 to 4 kg / 24 h
  • Condenser Temperature : -80 ℃
  • Rubber Valve : 24 piece s for 24 ampules
  • Final Vacuum : < 10 Pa
Bench-top Standard Freeze Dryer LBFD-A23

Bench-top Standard Freeze Dryer LBFD-A23

  • Drying Area : 0.18 ㎡
  • No-load Temperature : Min.to Less than or Equal - 68℃ (cold trap)
  • Cold Trap Volume : 13 Liters
  • Ice Holding Capacity : 6 Kg
Bench-top Manifold Top Press Freeze Dryer LBFD-E11

Bench-top Manifold Top Press Freeze Dryer LBFD-E11

  • Condenser Temperature : - 80°C
  • Condenser Capacity : 3 kg / 24 h
  • Freeze Drying Area : 0.1 m²
  • Bulk Capacity : 1 L
Bench-top Standard Freeze Dryer LBFD-A19

Bench-top Standard Freeze Dryer LBFD-A19

  • Drying Area : 0.12 ㎡
  • No-load Temperature : Min.to Less than or Equal -68℃ (cold trap)
  • Cold Trap Volume : 13 Liters
  • Ice Holding Capacity : 6 Kg

Bench-top Manifold Freeze Dryer LBFD-D16 FAQ's
  • Our freeze dryer has a 0.09 ? drying area with 10 manifold tubes, allowing multiple samples to be processed at once. It includes three removable and adjustable shelves, each with a 200 mm diameter tray. The cold trap reaches temperatures as low as -60?, and the vacuum system achieves up to 1 Pa for effective sublimation. With a 4 kg ice holding capacity and quiet operation (?55 dB), it is ideal for labs that need a compact but powerful solution for sensitive material preservation.

  • Our Labtron Bench-top Manifold Freeze Dryer is designed for preserving heat- and moisture-sensitive materials by removing water through a process called freeze-drying or lyophilization. It is commonly used in laboratories, pharmaceutical production, and biotechnology research. This process helps extend the shelf life of materials such as biological samples, vaccines, enzymes, and other sensitive products without damaging their structure or effectiveness.

  • The freeze dryer is equipped with a PID controller, which provides precise control of the temperature on the shelves. These shelves are coated with advanced aerospace-grade heating film to maintain even and stable heating. The system also includes a high-power condenser and internal condenser coils that ensure efficient cooling. The vacuum pressure is closely monitored to maintain optimal drying conditions, which is essential for achieving high-quality results, especially with delicate materials.

  • This freeze dryer is built with both performance and ease of use. It features a curved, integrated structure for a compact and ergonomic design. Its stainless steel 304 top surface provides excellent corrosion resistance and is easy to clean. The control system monitors not only the drying process in real time but also keeps track of the vacuum pump’s running hours. This helps users know when to change the oil, preventing equipment failure and improving reliability. These features help lab technicians work more efficiently and safely.

  • Labtron includes multiple safety features in the freeze dryer to protect the equipment and materials. One of these is thermal overload protection, which prevents the system from overheating during long operation hours. The hermetic compressor ensures leak-proof operation and stable performance. Also, if the system detects that the vacuum is not reaching the desired level, it can take necessary actions to prevent damage. These safety features help prevent product loss and extend the life of the machine.

Post your question?

Our experts are here to help!

Laboratory Bench-top Freeze Dryer:
Bench-top T-type Freeze Dryer LBFD-B13, Bench-top Standard Freeze Dryer LBFD-A21, Bench-top Manifold Freeze Dryer LBFD-D14, Bench-top Manifold Freeze Dryer LBFD-D18, Bench-top T-Type Freeze Dryer LBFD-B18, Bench-top Standard Freeze Dryer LBFD-A23, Bench-top Manifold Top Press Freeze Dryer LBFD-E11, Bench-top Standard Freeze Dryer LBFD-A19, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.