Request A Quote
Floor Model T-type Freeze Dryer LFFD-B14

Floor Model T-type Freeze Dryer LFFD-B14

Floor Model T-type Freeze Dryer LFFD-B14 features a condenser temperature of -70°C. It has a highly efficient vacuum system, and the connection pipe uses a stainless-steel tube. The freeze dryer has a corrosion-resistant construction and offers long-term durability. Additionally, it features various safety mechanisms such as short circuit protection and proactive reminders. Our freeze dryer is suitable for use in the freeze-drying of small samples used in laboratories.

Request Quote
Condenser Temperature - 70℃
Condenser Capacity 12 kg
Cold Trap Volume 20 L
Number of Ports 12
Pumping Capacity 8 m³/h
Vacuum Level 5×10⁻³ mbar
Display 5.4-inch color touchscreen
Anti-Corrosive Treatment PTFE-coated trap and coil (T-type)
Vacuum Pump Pipe Connection Single stainless steel flexible pipe
Vacuum Pipe Length 1.2 m
Power Consumption 1000 W
Power Supply 220 V / 50 Hz
Dimensions 525 × 570 × 1080 mm
Weight 82 kg
  • LCD display

  • Cold trap defrost function

  • Stainless steel T-frame

  • Compatible with various vacuum pumps

  • User-friendly interface

Our Floor Model T-type Freeze Dryer LFFD-B14 is perfect for handling limited quantities of sensitive materials, preserving them for research or testing. It is commonly used in laboratories for small-batch experimentation.

Two-stage Rotary Vane Pump I (Ultimate Vacuum: 5 × 10-3 mbar, Pumping Rate: 8 m3/h) × 1

Sr. No.

Name

Specifications

1

Two-stage Rotary Vane Pump I 

Ultimate Vacuum: 5 × 10-3 mbar

Pumping Rate: 8 m3/h

2

Two-stage Rotary Vane Pump II 

Ultimate Vacuum: 5 × 10-3 mbar

Air extraction Rate: 10 m3/h

3

Two-stage Rotary Vane Pump III

Ultimate Vacuum: 2 × 10-3 mbar

Pumping Rate: 6 m3/h

4

Two-stage Rotary Vane Pump 1V

Ultimate Vacuum: 2 × 10-3 mbar

Pumping Rate: 5.7 m3/h

5

Chemical Corrosion-proof Vacuum Pump

Ultimate Vacuum: 2 × 10-3 mbar

Pumping Rate: 8 m3/h

6

Chemical Hybrid pump

Ultimate Vacuum: 2 × 10-3 mbar

Air extraction Rate: 5.9 m3/h

7

Scroll Dry Pump

Ultimate Vacuum: 2 × 10-2 mbar

Pumping Rate: 6.2 m3/h

8

Vacuum Pump Oil (5 L)

5 L/barrel

9Capping device (vial)Vial
  • Eutectic point detection function

  • Data Output and analysis system

Models of Laboratory Floor model Freeze Dryer

Labtron Laboratory Floor model Freeze Dryer is specialized to create vacuum, and gently heat sample allowing ice to sublimate and cool samples. They feature programmable controls for precise temperature and pressure adjustments throughout cycle. Their condensation surface collects moisture vapor, preventing contamination of dried products during processing. They are equipped with easy-to-clean stainless steel surfaces, ensuring hygiene and longevity. Our Laboratory Floor model Freeze Dryer is versatile for food industry, cosmetics, neutraceuticals and pharmaceutical.

Floor Model Standard Freeze Dryer LFFD-A16

Floor Model Standard Freeze Dryer LFFD-A16

  • Condenser Temperature : - 70℃
  • Condenser Capacity : 12 kg
  • Cold Trap Volume : 20 L
  • Freeze-Dried Chamber Type : Acrylic chamber
Floor Model Top Press Freeze Dryer LFFD-C15

Floor Model Top Press Freeze Dryer LFFD-C15

  • Drying Area : 0.08 m²
  • Condenser Temperature : -80 ℃
  • Vacuum Degree :
  • Condenser Capacity : 3 to 4 kg/24 hours
Floor Model Manifold Freeze Dryer LFFD-D10

Floor Model Manifold Freeze Dryer LFFD-D10

  • Condenser temperature : - 50 °C
  • Condenser capacity : 3 kg / 24 h
  • Freeze drying area : 0.12 m²
  • Bulk capacity : 1.2 L
Floor Model Top Press Freeze Dryer LFFD-C16
Floor Model Top Press Freeze Dryer LFFD-C16
  • Drying Area : 0.1 m²
  • Condenser Temperature : -50 ℃
  • Vacuum Degree :
  • Condenser Capacity : 3 to 4 kg/24 hours
Floor Model Standard Freeze Dryer LFFD-A11
Floor Model Standard Freeze Dryer LFFD-A11
  • Condenser Temperature : - 80°C
  • Condenser Capacity : 3 kg / 24 h
  • Freeze Drying Area : 0.18 m²
  • Bulk Capacity : 1.8 L
Floor Model Manifold Freeze Dryer LFFD-D11

Floor Model Manifold Freeze Dryer LFFD-D11

  • Condenser temperature : - 80 °C
  • Condenser capacity : 6 kg / 24 h
  • Freeze drying area : 0.18 m²
  • Bulk capacity : 1.8 L
Floor Model Standard Freeze Dryer LFFD-A12

Floor Model Standard Freeze Dryer LFFD-A12

  • Cold Trap Temperature : ≤ -56°C
  • Condenser Capacity : 6 kg/24 h
  • Freeze Drying Area : 0.27 m2
  • Bulk Capacity : 2.7 L
Floor Model T-Type Freeze Dryer LFFD-B16

Floor Model T-Type Freeze Dryer LFFD-B16

  • Condenser Capacity : 3 kg / 24 h
  • Condenser Temperature : -50 ℃
  • Vacuum Degree : < 10 Pa
  • Rubber Valve : 24 pieces for 24 ampules
Floor Model T-type Freeze Dryer LFFD-B14 FAQ's
  • Labtron’s Floor Model T-type Freeze Dryer can handle a wide range of materials, including biological samples, pharmaceuticals, plant extracts, enzymes, and food products. It has PTFE-coated, corrosion-resistant internal components. This dryer is suitable for heat-sensitive substances that require precise and gentle drying under vacuum.

  • Yes, our Floor Model T-type Freeze Dryer is designed to be compatible with various vacuum pumps. This allows users to choose pumps that meet their requirements, whether for achieving deeper vacuum levels, improving drying speed, or handling specific types of samples. It is compatible with a wide range of vacuum pumps offering a versatile range of applications for freeze drying.

  • Our Floor Model T-type Freeze Dryer supports data output and analysis systems that record parameters like temperature, vacuum level, and time. This feature is customizable and offers data that is valuable for optimizing freeze-drying cycles, maintaining records, and ensuring consistency in repeated processes.

  • Safety and precision are the priorities at Labtron. Our Floor Model T-type Freeze Dryer includes over-temperature protection, and maintenance alerts. These features help safeguard both the equipment and the materials being processed. Also, user’s safety is a key feature of any Labtron product so our freeze dryer has short circuit protection feature.

  • The cold trap collects and freezes water vapor from the drying chamber, preventing it from reaching the vacuum pump. It requires regular defrosting and cleaning to maintain efficiency and avoid damage or performance loss in the vacuum system. This not only protects the equipment but also maintains stable vacuum conditions, ensuring efficient and effective freeze-drying.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608