Laser Particle Size Analyzer LLPA-A21 is designed for precise and automatic particle size measurement ranging from 0.1 to 1000 µm. It utilizes the advanced Mie scattering principle along with a converging Fourier transform optical path. The analyzer features a high-density probe and full-range seamless connection test method. Its unique wet circulation and dispersion system minimizes particle deposition and eliminates waste liquid residue. Our analyzer is used for accurate measurement and analysis of particle size distribution in liquids and powders.

Request Quote
Dispersion Type Wet
Measurement Range 0.01 μm to 1000 μm
Number of Detector Channels 96
Accuracy Error Less than 5% (D50 value of National Standard Sample)
Repeatability Error Less than 5% (D50 value of National Standard Sample)
Laser Source Fiber output laser, λ = 635 nm, P is greater than 10 MW
Optical Calibration Automatic in X and Y axis
Dispersion Method Ultrasonic, 40 kHz, 100 W, Arbitrarily adjustable timing with ultrasonic anti dry burning
Circulation Flow Rate 0 to 30 L/min, 25 W
Circulation Mixing Speed 100 to 33950 rpm, adjustable
Sample Cell Capacity 190 to 600 mL (self-designed boiling sample cell)
Testing Speed Less than 1 min per test (excluding sample dispersion time)
Operation Mode Computer-based operation
Dimensions 800 × 280 × 335 mm
Net Weight 40 kg
  • One-touch intelligent operation

  • Micro-circulation with no residue design

  • Misoperation self-protection function

  • Fogging detection system

  • Bubble-free design

  • Sealed, dust proof and shock resistant body

Our Laser Particle Size Analyzer LLPA-A21 is used for precise particle size analysis in industries such as pharmaceuticals, chemicals, cement, ceramics, mining, and food processing. It supports quality control, research, and formulation by providing accurate particle distribution data for powders, suspensions, and emulsions.

Models of Laser Particle Size Analyzer

Labtron Laser Particle Size Analyzer offers advanced, fully automatic solutions for both wet and dry particle size analysis. They utilize MIE scattering principles and high-sensitive detectors. They provide particle size distribution measurements across various ranges from 0.01 µm to 2000 µm. Test speeds of less than 2 minutes for wet dispersion and under 1 minute for dry dispersion ensure rapid results. Their SOP operation mode, alongside various analysis modes and statistical methods, facilitates comprehensive data processing and analysis. Our Laser Particle Size Analyzer supports both automatic and manual operation modes, offering flexibility and user-friendly functionality.

Laser Particle Size Analyzer LLPA-A11

Laser Particle Size Analyzer LLPA-A11

  • Dispersion Type : Wet
  • Measurement Range : 0.01 to 2000 µm
  • Channel number : 127
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-A14

Laser Particle Size Analyzer LLPA-A14

  • Dispersion Type : Wet
  • Measurement Range : 0.01μm to 2000μm
  • Channel Number : 116
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-C10

Laser Particle Size Analyzer LLPA-C10

  • Dispersion Type : Wet and Dry
  • Measurement Range : Wet: 0.1 to 2000 µmDry: 0.1 to 2000 µm
  • Channel number : Wet: 128Dry: 118
  • Accuracy Error : Wet and Dry:
Laser Particle Size Analyzer LLPA-A13
Laser Particle Size Analyzer LLPA-A13
  • Dispersion Type : Wet
  • Measurement Range : 0.01 to 2000 µm
  • Channel number : 87
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-A10
Laser Particle Size Analyzer LLPA-A10
  • Dispersion Type : Wet
  • Measurement Range : 0.1 to 300 µm
  • Channel number : 39
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-B11

Laser Particle Size Analyzer LLPA-B11

  • Dispersion Type : Dry
  • Measurement Range : 0.1 to 300 µm
  • Channel number : 40
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-B21

Laser Particle Size Analyzer LLPA-B21

  • Dispersion Type : Dry
  • Measurement Range : 0.1 to 2000 µm
  • Number of Channels : 120
  • Accuracy Error : Less than 1%
Laser Particle Size Analyzer LLPA-A12

Laser Particle Size Analyzer LLPA-A12

  • Dispersion Type : Wet
  • Measurement Range : 0.1 to 1000 µm
  • Channel number : 90
  • Accuracy Error :
Laser Particle Size Analyzer LLPA-A21 FAQ's
  • Labtron’s Laser Particle Size Analyzer LLPA-A21 applies the Mie scattering principle, which analyzes how laser light is scattered by particles based on their size and optical properties. A laser beam passes through the dispersed sample, and scattered light is detected at different angles. Using this data, the system calculates the particle size distribution with high precision. Mie scattering is ideal for a wide range of particle sizes and materials, making it more accurate than basic diffraction methods, especially in industries that demand tight particle control like pharmaceuticals and advanced materials.

  • The converging Fourier transform optical path allows the Laser Particle Size Analyzer LLPA-A21 to capture scattered light efficiently without requiring a long optical bench. This optical configuration maintains high measurement resolution in a compact system, enabling precise detection of particle size distribution over a wide range. It also ensures optical stability, which is crucial for repeated testing and long-term use in research and production environments.

  • Our Laser Particle Size Analyzer LLPA-A21 features a sealed wet circulation system with a micro-circulation design that avoids dead zones and eliminates residual liquid. An integrated ultrasonic disperser (40 kHz, 100 W) ensures thorough mixing and prevents particle agglomeration. This setup is essential for accurate measurement of powders, emulsions, or viscous suspensions, as it ensures each test begins with a uniformly dispersed sample.

  • The Laser Particle Size Analyzer LLPA-A21 includes intelligent one-touch operation, automatic optical path calibration on both X and Y axes, and a misoperation protection function. It also features a fogging detection system that maintains optical clarity. These features simplify operation, reduce user error, and allow even non-specialists to perform consistent tests safely and accurately.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.