info@labtron.com +44 2080 043608
Laser Particle Size Analyzer LLPA-C10

Laser Particle Size Analyzer LLPA-C10

Laser Particle Size Analyzer LLPA-C10 is a fully automatic unit integrated with wet and dry dispersion. With Laser diffraction principle and Mie and Fraunhofer scattering, features wet measuring range of 0.01 to 2000 µm and dry measuring range of 0.1 to 2000 µm. Designed with semiconductor lasers, log-spaced array detector and silicon photodetectors, offers full-automatic and manual operation mode with automatic optical path alignment system. Built-in sample dispersion system and unconstrained free fitting technology comprised software, provides high precision data with <2 min test time for wet dispersion and <1 min test time for dry dispersion. With different analysis mode, statistic method and comparison, it supports intelligent operation, user-defined analysis and test reports in various format.

Request Quote
Dispersion Type Wet and Dry
Measurement Range Wet: 0.01 to 2000 µm
Dry: 0.1 to 2000 µm
Photodetectors Silicon photodetectors
Channel number Wet: 127
Dry: 100
Accuracy Error Wet and Dry: <1% (National Standard Sample D50)
Repeatability Error Wet and Dry: <1% (National Standard Sample D50)
Light Source High performance semiconductor laser( λ= 632.8nm P >2.0 mW)
Auxiliary blue semiconductor laser (λ= 405 nm, P >2.0 mW)
Detector Log-spaced array
Test angle from 0.015 degree to 145 degree
Wet Dispersion
Ultrasonic Frequency40 kHz
Ultrasonic Time≥1 S
Ultrasonic Power60 W
Stir Revolution speed0 to 300 rpm (Adjustable)
CirculationRated Flow: 30 L/min
Rated Power: 70 W
Sample tank1000 ml
Dry Dispersion Dry-turbulence dispersion
Normal shock wave shear technique
Optical Path Alignment Fully automatic
Operation mode Automatic/ Manual (Switchable)
Standard ISO 13320-1:2009
Test Speed Wet: <2 min
Dry : <1min
Typical measuring time: < 10s
Software Running WIN 7/10/XP, 64 bits
Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method Volume Distribution, Quantity Distribution
Test Report Word, Excel, Photo( Bmp), Text etc.
Intelligent operation Intelligent SOP operation
Dimension (L×W×H) 1040×440×540 mm
Net Weight 70 kg
  • A fully automatic unit integrated with wet and dry dispersion, convenient operation
  • Laser diffraction principle and Mie and Fraunhofer scattering, rapid measurement
  • Wet measuring range of 0.01 to 2000 µm and dry measuring range of 0.1 to 2000 µm
  • Semiconductor lasers with log-spaced array detector and silicon photodetectors
  • Full-automatic and manual operation mode with automatic optical path alignment system
  • Built-in sample dispersion system, ensures sufficient dispersion and accurate result
  • Unconstrained free fitting technology comprised software, offers high precision data
  • <2 min test time for wet dispersion and <1 min test time for dry dispersion
  • Different analysis mode, statistic method and comparison, meet different requirements
  • Supports intelligent operation, user-defined analysis and test reports in various format
  • Designed as per ISO 13320-1:2009 standard configurations
  • High-efficient, stable and reliable unit for accurate and repeatable results

Laser particle size analyzer is used to measure the sizes of particles in a material across cosmetics, food, coal, paint, paper, petrochemical, dyes, inks, explosives, , kaolin, medicine, metal powder, mica, milling, minerals, oxides industries etc.

10 ml micro sample pool

Compare Models

Model Dispersion Type Measurement Range Photodetectors Channel number Accuracy Error Repeatability Error Light Source Detector Dry Dispersion Optical Path Alignment Operation mode Standard Test Speed Software Running Analysis mode Statistic Method Test Report Intelligent operation Dimension (L×W×H) Net Weight
LLPA-A10 Wet 0.1 to 300 µm - 39 <1% (National Standard Sample D50) <1% (National Standard Sample D50) High performance semiconductor laser λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
High-sensitive ring photoelectric detector - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2009 <2 min/time WIN 7/10/XP, 64 bits Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. Intelligent SOP operation 880×390×460 mm 41 kg
LLPA-A11 Wet 0.01 to 2000 µm - 127 <1% (National Standard Sample D50) <1% (National Standard Sample D50) High performance semiconductor laser λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
Dual-beam and multiple spectral detection - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2010 <2 min/time WIN 7/10/XP, 64 bits Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. Intelligent SOP operation 660×320×400 mm 65 kg
LLPA-A12 Wet 0.1 to 1000 µm - 90 <1% (National Standard Sample D50) <1% (National Standard Sample D50) High performance semiconductor laser λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
High-sensitive ring-shaped multi-element silicon photo-diode detector - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2011 <2 min/time WIN 7/10/XP, 64 bits Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. Intelligent SOP operation 850×390×450 mm 41 kg
LLPA-A13 Wet 0.01 to 2000 µm - 87 <1% (National Standard Sample D50) <1% (National Standard Sample D50) High performance semiconductor laser λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
High-sensitive ring-shaped multi-element silicon photo-diode detector - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2012 <2 min/time WIN 7/10/XP, 64 bits Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. Intelligent SOP operation 850×390×450 mm 41 kg
LLPA-B10 Dry 0.1 to 2000 µm - 100 <1% (National Standard Sample D50) <1% (National Standard Sample D50) Semiconductor laser, λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
High-sensitive ring photoelectric detector - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:1999 <1 min/time WIN 7/10/XP, 64 bits - Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. - 1040×440×540 mm 58 kg
LLPA-B11 Dry 0.1 to 300 µm - 40 <1% (National Standard Sample D50) <1% (National Standard Sample D50) Semiconductor laser, λ = 632.8 nm,
P > 2 mW,
Service life > 25000 hours
High-sensitive ring photoelectric detector - Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2000 <1 min/time WIN 7/10/XP, 64 bits - Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. - 880×410×300 mm 36 kg
LLPA-C10 Wet and Dry Wet: 0.01 to 2000 µm
Dry: 0.1 to 2000 µm
Silicon photodetectors Wet: 127
Dry: 100
Wet and Dry: <1% (National Standard Sample D50) Wet and Dry: <1% (National Standard Sample D50) High performance semiconductor laser( λ= 632.8nm P >2.0 mW)
Auxiliary blue semiconductor laser (λ= 405 nm, P >2.0 mW)
Log-spaced array
Test angle from 0.015 degree to 145 degree
Dry-turbulence dispersion
Normal shock wave shear technique
Fully automatic Automatic/ Manual (Switchable) ISO 13320-1:2009 Wet: <2 min
Dry : <1min
Typical measuring time: < 10s
WIN 7/10/XP, 64 bits Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Volume Distribution, Quantity Distribution Word, Excel, Photo( Bmp), Text etc. Intelligent SOP operation 1040×440×540 mm 70 kg

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608