Liquid Particle Counter LLPC-A21 is used for detecting the size and quantity of solid particles in liquids by the principle of the light blocking method. It can measure the pollution levels and insoluble particles solid particles in oil samples. Its desktop design offers less space consumption for in small working space. The counter is easy to calibrate and offers great accuracy and can meet the standard requirement. Additionally, it configures high-performance large-sized particle counting sensors. Our particle counter supports an industrial computer Windows system allows instrument control and calculation.

Liquid Particle Counter LLPC-A21_
Liquid Particle Counter LLPC-A21_2
Request Quote
Light Source Semiconductor laser
Particle Size Range 1~100 μm or 4~70 μm
Detection Channels 32 pieces, can be 0.01μm interval arbitrary set particle size
Sensitivity 1μm or 4μm
Resolution Better than 10%
Sample Detection Viscosity < 650 cSt
Sampling Volume 0.3 ~ 100ml, 0.1ml interval
Sampling Accuracy ± 41/2 rating
Sampling Speed 5 ~ 60 ml/min
Power Supply 220 V ± 10%,50 Hz;180 W
Dimensions (L×D×H) 355 × 400 × 620 mm
Net Weight 19 kg
  • Highly accurate 

  • Different Calibration options for sample type 

  • Computer connectivity

  • Display screen

  • User-friendly

The Liquid Particle Counter LLPC-A21 is designed to detect the size and quantity of solid particles in liquids by the principle of the light blocking method. Our particle counter supports an industrial computer Windows system allows instrument control and calculation.

Models of Liquid Particle Counter

Labtron liquid particle counters provide precise and dependable results by detecting and counting particles using the photoresist technique. They have extensive detection ranges, several measurement channels, and high-precision laser sensors. These have sophisticated data processing systems, integrated printers, and LCD panels for easy operation and analysis. They offer low noise levels and consistent performance in accordance with international standards. Our liquid particle counters come with air purification systems for various sectors and allow several calibration curves.

Liquid Particle Counter LLPC-A20

Liquid Particle Counter LLPC-A20

  • Particle Size Range : 0.8μm to 600μm
  • Sensitivity : 0.8μm or 3μm (selectable)
  • Light Source : Semiconductor laser
  • Detection Channels : 8 to 64 channels
Liquid Particle Counter LLPC-A10

Liquid Particle Counter LLPC-A10

  • Measurement range : 1 to 250 µm (25 sensors) 1 µm to 320 µm (32 sensors) 2 µm to 400 µm (40 sensors)
  • Light Source : Semiconductor laser light
  • Measurement Channels : 8 channels
  • Particle size : 1 µm (2 µm) to arbitrarily set within 100 µm
Liquid Particle Counter LLPC-A30

Liquid Particle Counter LLPC-A30

  • Test range : 1 to 500μm
  • Full channel settings : ≥5μm, ≥8μm, ≥10μm, ≥12μm, ≥25μm, ≥100μm (customizable)
  • Pharmacopoeia standards : ≥10μm, ≥25μm
  • Drug packaging material channel : ≥5μm, ≥10μm, ≥25μm
Liquid Particle Counter LLPC-A21 FAQ's
  • Liquid Particle Counter LLPC-A21 is designed to test a wide range of oils and fluids, including hydraulic oils, lubricating oils, turbine oils, and synthetic fluids used in various industries such as aviation, power generation, and manufacturing. It handles fluids with viscosity up to approximately 320 cSt. For higher viscosity samples, pre-heating or dilution may be required. Ensuring the fluid is free of air bubbles and moisture is important for accurate and consistent particle measurement results.

  • Labtron’s Liquid Particle Counter LLPC-A21 supports major oil cleanliness standards such as ISO 4406, NAS 1638, SAE AS4059, and GJB 420, which are commonly used in industrial and military applications. It reports contamination levels by counting particles in different size ranges, typically from 4 microns up to 100 microns. The results are displayed either as absolute particle counts or as standard cleanliness codes, helping users interpret contamination levels and decide on maintenance or oil replacement actions.

  • For low-viscosity oils, Labtron’s Liquid Particle Counter LLPC-A21 can usually test the sample directly without dilution. However, for high-viscosity or heavily contaminated oils, pre-treatment steps such as heating, dilution with a compatible solvent, or vacuum degassing may be needed to ensure smooth sample flow and accurate particle detection. These preparations help eliminate air bubbles and ensure that the instrument provides reliable and repeatable readings, especially in samples that are dark or prone to foaming.

  • Routine maintenance of the Labtron’s Liquid Particle Counter LLPC-A21 includes cleaning the sample path and flushing the system regularly to prevent clogging and contamination, especially after testing dirty or viscous oils. Calibration is typically done using ISO 11171-certified calibration fluids to ensure the optical system remains accurate. Users are advised to perform verification checks periodically using standard reference fluids. The built-in software assists with calibration alerts and maintenance schedules, supporting consistent performance and reliable cleanliness data.

  • Labtron’s Liquid Particle Counter LLPC-A21 uses the light blockage method, where a laser beam shines through the oil sample and particles passing through block the light. Each interruption is detected and measured, allowing the instrument to count and size the particles accurately. This method provides precise contamination analysis and supports rapid testing of oils and fluids. It is widely used for monitoring oil cleanliness in accordance with standards such as ISO 4406, NAS 1638, and SAE AS4059.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.