Request A Quote
Low Temperature Circulating Chiller LLTC-B10

Low Temperature Circulating Chiller LLTC-B10

Low Temperature Circulating Chiller LLTC-B10 offers a temperature range of -25°C to 30°C, ensuring optimal cooling. It enables fast temperature recovery after load changes. The system provides consistent performance across ambient variations. Its noise-reduction design supports quiet operation. Our chiller is used in materials testing, pharmaceutical development, biotechnology labs, electronic device calibration, and laser systems.

Request Quote
Temperature Range -25°C to 30°C
Temperature Control ±0.5°C
Circulation Pump Max 2.5m³/h 2 bar
Refrigerant R448A/R507C
Cooling Capacity at -5°C 10.2 kW
Cooling Capacity at -15°C 7 kW
Power 400V 50HZ / 460V 60HZ
  • Extended Cooling Range
  • Low-GWP Refrigerant Use
  • Compact Industrial Design
  • High-Precision Control
  • Smart Diagnostic System

Our Low Temperature Circulating Chiller is used in materials testing, pharmaceutical development, biotechnology labs, electronic device calibration, laser systems, chemical synthesis, reactor cooling, fuel cell testing, vacuum systems, automotive analysis.

Low Temperature Circulating Chiller LLTC-B10 | Refrigerant : R448A/R507C | Cooling Capacity at -5°C : 10.2 kW
Low Temperature Circulating Chiller LLTC-B10 | Extended Cooling Range | Low-GWP Refrigerant Use

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-H10

Low Temperature Circulating Chiller LLTC-H10

  • Temperature Range : -40°C to 90°C
  • Temperature Control : ±0.3°C
  • Circulation Pump Max : 20L/min 2 bar
  • Refrigerant : R-448A/R507C
Low Temperature Circulating Chiller LLTC-A15

Low Temperature Circulating Chiller LLTC-A15

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 28m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-F15

Low Temperature Circulating Chiller LLTC-F15

  • Temperature Range : -115°C to -80°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 40L/min 2 bar
  • Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-F13
Low Temperature Circulating Chiller LLTC-F13
  • Temperature Range : -115°C to -80°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 20L/min 2 bar
  • Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-C15
Low Temperature Circulating Chiller LLTC-C15
  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 7.7m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-D12

Low Temperature Circulating Chiller LLTC-D12

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 5.3m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-D13

Low Temperature Circulating Chiller LLTC-D13

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 7m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-D11

Low Temperature Circulating Chiller LLTC-D11

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 3.8m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-B10 FAQ's
  • The Low Temperature Circulating Chiller offers a temperature range from -25°C to 30°C, ensuring optimal cooling for various applications. This range allows it to handle both low and moderately high temperatures, making it versatile for diverse industrial and laboratory needs. It is particularly effective for temperature-sensitive processes that require precise thermal management. The system maintains consistent temperature stability even with fluctuating ambient conditions, ensuring reliable performance.

  • Yes, the chiller is ideal for pharmaceutical development, ensuring precise temperature control in critical processes. It helps maintain consistent temperatures for drug formulation, storage, and testing, crucial for product efficacy. Its reliable performance supports compliance with regulatory standards in pharmaceutical research and production. The chiller also ensures the stability of sensitive compounds, reducing risks during experiments and ensuring accurate results.

  • Absolutely, the Low Temperature Circulating Chiller is designed to support materials testing by providing reliable and consistent cooling performance. It ensures precise temperature control, crucial for evaluating material properties. The chiller helps simulate real-world conditions, testing materials under various temperature conditions for durability and performance. Its stable cooling capabilities enable accurate testing, allowing researchers to make informed decisions based on reliable data.

  • The chiller offers stable and accurate temperature control, which is crucial for laser systems requiring precise cooling for optimal performance. Its reliable cooling ensures consistent laser output, preventing overheating or fluctuations that could affect the system's operation and result in failure. Additionally, its rapid recovery time after load changes maintains system efficiency during continuous operations.

  • The chiller uses environmentally friendly refrigerants, R448A/R507C, designed to offer reliable cooling performance with minimal environmental impact. These refrigerants provide efficient heat exchange while reducing the chiller's carbon footprint, making the system both energy-efficient and compliant with modern environmental standards. They help maintain optimal cooling performance in various temperature-sensitive applications without compromising the environment.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.