Low Temperature Circulating Chiller LLTC-G10 enables fast and reliable heating with its 3.5 kW heating power. It incorporates built-in high and low pressure sensors for enhanced operational safety. Its PLC-based logic enhances automation and control reliability. The refrigeration cycle is optimized for energy efficiency. Our chiller supports pharmaceutical production by maintaining precise temperature control during mixing, crystallization, and fermentation.

Request Quote
Temperature Range 5°C to 90°C
Temperature Control PLC controller, control the water tank outlet temperature
Temperature Control Accuracy ±0.3°C
Circulation Pump Max 20L/min 2 bar
Refrigerant R-134A/R407C
Heating Power 3.5 kW
Cooling Capacity at 10°C 4 kW
Power AC380V 50HZ / AC460V 50HZ
  • Advanced Self-Diagnosis Feature
  • Comprehensive Overload Protection
  • Reliable Thermal Protection
  • Cold Rolled Steel Shell
  • Dual Heating Cooling Mode

Our Low Temperature Circulating Chiller supports pharmaceutical production by maintaining precise temperature control during mixing, crystallization, and fermentation, helping ensure product quality, batch consistency, and regulatory compliance.

Low Temperature Circulating Chiller LLTC-G10 | Circulation Pump Max : 20L/min 2 bar | Refrigerant : R-134A/R407C
Low Temperature Circulating Chiller LLTC-G10 | Advanced Self-Diagnosis Feature | Comprehensive Overload Protection

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-B13

Low Temperature Circulating Chiller LLTC-B13

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 6.7m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-C10

Low Temperature Circulating Chiller LLTC-C10

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 1.5m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-D11

Low Temperature Circulating Chiller LLTC-D11

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 3.8m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-D12
Low Temperature Circulating Chiller LLTC-D12
  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 5.3m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-A15
Low Temperature Circulating Chiller LLTC-A15
  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 28m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-F14

Low Temperature Circulating Chiller LLTC-F14

  • Temperature Range : -115°C to -80°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 30L/min 2 bar
  • Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-C14

Low Temperature Circulating Chiller LLTC-C14

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 6.8m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-A11

Low Temperature Circulating Chiller LLTC-A11

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 5m³/h 2 bar
  • Refrigerant : R134A/R407C
Low Temperature Circulating Chiller LLTC-G10 FAQ's
  • The Low Temperature Circulating Chiller offers a temperature range from 5°C to 90°C, ensuring precise control for various applications. This wide range allows the chiller to accommodate both heating and cooling requirements. It is designed for applications that require consistent and accurate temperature regulation. The chiller's versatility makes it ideal for industries such as pharmaceuticals, biotechnology, and chemical processing. With reliable performance across this range, it helps maintain the integrity of sensitive processes.

  • The Low Temperature Circulating Chiller provides 3.5 kW of heating power for fast and reliable heating. This high heating capacity ensures rapid temperature adjustments, improving overall process efficiency. It is designed to handle both cooling and heating cycles effectively, making it versatile for various industrial applications. Whether for maintaining precise temperatures or achieving quick temperature changes, this chiller offers consistent and dependable performance.

  • The Low Temperature Circulating Chiller maintains precise temperature control during processes like mixing, crystallization, and fermentation, which helps ensure product quality and regulatory compliance. By maintaining consistent temperatures, the chiller ensures that sensitive pharmaceutical processes are carried out under optimal conditions. This precision helps improve batch consistency, reduce variability, and enhance the overall reliability of production. Additionally, the chiller plays a crucial role in meeting stringent regulatory requirements for temperature-sensitive products in the pharmaceutical industry.

  • It comes with built-in high and low pressure sensors, offering enhanced operational safety during use. These sensors help monitor and maintain optimal pressure levels, preventing potential damage to the system. The chiller also includes overload protection and thermal protection devices, ensuring reliable performance under various operating conditions. Additionally, the unit is equipped with self-diagnosis functions that provide real-time alerts, allowing for prompt identification and resolution of any issues.

  • The Low Temperature Circulating Chiller uses R-134A/R407C refrigerants for efficient cooling. These refrigerants are known for their excellent heat transfer properties and energy efficiency, ensuring optimal performance while maintaining environmental responsibility. R-134A and R407C are also commonly used in cooling systems, as they have a lower environmental impact compared to older refrigerants. By using these eco-friendly refrigerants, the chiller offers both reliable performance and compliance with global environmental standards.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.