Request A Quote
Low Temperature Circulating Chiller LLTC-G13

Low Temperature Circulating Chiller LLTC-G13

Low Temperature Circulating Chiller LLTC-G13 offers a high-capacity circulation pump with 100L/min 2 bar for efficient cooling.Its robust cooling efficiency ensures stable performance in demanding applications. The system includes high-pressure protection sensors for safety. It optimizes energy consumption while maintaining performance. Our chiller ensures temperature stability during cooling and heating in experiments testing new materials and coatings.

Request Quote
Temperature Range 5°C to 90°C
Temperature Control PLC controller, control the water tank outlet temperature
Temperature Control Accuracy ±0.3°C
Circulation Pump Max 100L/min 2 bar
Refrigerant R-134A/R407C
Heating Power 15 kW
Cooling Capacity at 10°C 20 kW
Power AC380V 50HZ / AC460V 50HZ
  • Efficient Energy Consumption
  • Rapid Temperature Adjustment
  • Reliable Process Scalability
  • Easy System Integration
  • Improved Operational Reliability

Our Low Temperature Circulating Chiller plays a critical role in cooling and heating during experiments, ensuring temperature stability during testing of new materials, coatings, and composites for improved product properties.

Low Temperature Circulating Chiller LLTC-G13 | Refrigerant : R-134A/R407C | Heating Power : 15 kW
Low Temperature Circulating Chiller LLTC-G13 | Efficient Energy Consumption | Rapid Temperature Adjustment

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-A14

Low Temperature Circulating Chiller LLTC-A14

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 19m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-C13

Low Temperature Circulating Chiller LLTC-C13

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 4.5m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-D12

Low Temperature Circulating Chiller LLTC-D12

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 5.3m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-G11
Low Temperature Circulating Chiller LLTC-G11
  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 35L/min 2 bar
Low Temperature Circulating Chiller LLTC-B11
Low Temperature Circulating Chiller LLTC-B11
  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 4.2m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-C14

Low Temperature Circulating Chiller LLTC-C14

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 6.8m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-G12

Low Temperature Circulating Chiller LLTC-G12

  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 50L/min 2 bar
Low Temperature Circulating Chiller LLTC-E14

Low Temperature Circulating Chiller LLTC-E14

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 11m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-G13 FAQ's
  • It is ideal for applications in material testing, product development, chemical reactions, and pilot-scale production, providing precise thermal control for both heating and cooling requirements. The chiller ensures stable temperature conditions, which is critical for maintaining consistency in results across various processes. Its versatility makes it suitable for industries such as pharmaceuticals, chemicals, biotechnology, and manufacturing.

  • The chiller is designed with energy-efficient components, including a high-capacity circulation pump and optimized heat exchangers, ensuring that cooling and heating are performed with minimal energy consumption. Additionally, its advanced PLC-based control system automatically adjusts the operation based on load conditions, optimizing energy usage. The use of high-quality insulation and low-power consumption features further enhances its energy efficiency, reducing operational costs while maintaining reliable performance.

  • Yes, the chiller is compatible with a variety of automated systems and process controls, integrating seamlessly into existing setups for enhanced process efficiency and thermal management. It features standard communication interfaces and protocols, allowing easy integration with lab equipment, manufacturing systems, and monitoring software. The chiller’s flexibility makes it ideal for use in a wide range of industries, from research labs to industrial production environments.

  • It ensures stable, controlled temperatures during experimental trials, making it invaluable for R&D where consistent thermal conditions are necessary for accurate testing and development. The chiller provides precise temperature control, minimizing the risk of fluctuations that could interfere with sensitive experiments. Its reliability supports a wide range of applications, from material testing to chemical reactions. By maintaining optimal conditions, it helps researchers achieve reproducible results, accelerating innovation and improving the quality of product development.

  • The chiller comes with built-in safety features, such as pressure sensors and automatic shutoffs, to prevent system overloads and ensure safe operation under varying temperature and pressure conditions. These safety mechanisms help prevent overheating, excessive pressure, and other risks that could damage the chiller or affect its performance. The system also includes temperature sensors to monitor both inlet and outlet temperatures in real-time, ensuring that the chiller operates within safe limits.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.