Low Temperature Circulating Chiller LLTC-F13 provides a cooling capacity of 1.1 kW at -90°C and 0.8 kW at -100°C for stable performance. Its durable construction withstands the rigors of continuous operation in demanding environments. It is equipped with an easy-to-access filter for routine maintenance, ensuring uninterrupted operation. The system operates across a wide temperature range, making it adaptable to various industrial needs. Our chiller provides stable cooling for biological and chemical research, pharmaceuticals, and laboratory testing.

Request Quote
Temperature Range -115°C to -80°C
Temperature Control PLC controller, control outlet temperature, 7-inch touch screen
Circulation Pump Max 20L/min 2 bar
Refrigerant Mixed refrigerant 2
Cooling Capacity at -90°C 1.1 kW
Cooling Capacity at -100°C 0.8 kW
Power 8.5kw max
  • Automatic Fault Detection System
  • Eco-Friendly Refrigerant Usage
  • Adjustable Pump Pressure
  • Fast Cooling Response Time
  • Advanced Temperature Regulation

Our Low Temperature Circulating Chiller provides stable cooling for biological and chemical research, pharmaceuticals, and laboratory testing, enabling precise temperature control to ensure optimal conditions for preservation, studies, and analysis.

Low Temperature Circulating Chiller LLTC-F13 | Circulation Pump Max : 20L/min 2 bar | Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-F13 | Adjustable Pump Pressure | Fast Cooling Response Time

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-C14

Low Temperature Circulating Chiller LLTC-C14

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 6.8m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-G12

Low Temperature Circulating Chiller LLTC-G12

  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 50L/min 2 bar
Low Temperature Circulating Chiller LLTC-B14

Low Temperature Circulating Chiller LLTC-B14

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 15m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-F10
Low Temperature Circulating Chiller LLTC-F10
  • Temperature Range : -100°C to -65°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 20L/min 2 bar
  • Refrigerant : Mixed refrigerant 1
Low Temperature Circulating Chiller LLTC-C11
Low Temperature Circulating Chiller LLTC-C11
  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 2.4m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-E12

Low Temperature Circulating Chiller LLTC-E12

  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 4.6m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-A13

Low Temperature Circulating Chiller LLTC-A13

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 14m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-G11

Low Temperature Circulating Chiller LLTC-G11

  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 35L/min 2 bar
Low Temperature Circulating Chiller LLTC-F13 FAQ's
  • The Low Temperature Circulating Chiller is ideal for biological and chemical research due to its precise temperature control, stable cooling capacity, and durable construction. It ensures optimal conditions for sensitive biological samples, providing consistent, ultra-low temperatures essential for preserving materials during experiments. The chiller offers high reliability, ensuring uninterrupted operation during critical research processes. Additionally, its advanced control mechanisms maintain temperature stability, contributing to accurate and reproducible results across a wide range of laboratory applications.

  • The Low Temperature Circulating chiller ensures minimal downtime through its easy-access filter and reliable components designed for low maintenance, supporting continuous operation in demanding environments. Its robust construction reduces the risk of breakdowns, making it ideal for long-term use in both industrial and laboratory settings. The user-friendly design enables quick and efficient servicing, minimizing downtime. Additionally, the chiller is equipped with automatic diagnostic functions, alerting users to potential issues before they lead to significant disruptions, ensuring consistent performance.

  • The Low Temperature Circulating Chiller operates with a maximum power consumption of 8.5 kW, ensuring efficient and reliable cooling while minimizing energy use. This power requirement allows the chiller to maintain ultra-low temperatures effectively without excessive energy consumption, making it both cost-efficient and environmentally friendly. The system is designed to deliver optimal cooling performance in industrial and laboratory environments while adhering to energy efficiency standards. Its power consumption is well-balanced, ensuring consistent performance without unnecessary strain on energy resources.

  • The Low Temperature Circulating chiller performs optimally in controlled environments, but extreme external temperature conditions can slightly affect its efficiency. When exposed to very high or low ambient temperatures, the chiller may need to work harder to maintain the desired cooling levels, potentially leading to increased energy consumption. To ensure the best performance and efficiency, it is recommended to operate the chiller within the specified temperature range. This helps maintain stable cooling and prevents overloading the system, ensuring long-term reliability and consistent results.

  • Yes, the Low Temperature Circulating chiller is ideal for controlled laboratory settings, where precise and stable low temperatures are required for scientific research and testing. Its ability to maintain consistent cooling ensures that sensitive samples and materials are preserved under optimal conditions. The chiller is designed to meet the rigorous demands of various laboratory applications, from biological studies to chemical analysis. Its reliable performance and advanced control systems make it a perfect choice for environments that require accurate temperature regulation and minimal fluctuations for accurate experimental results.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.