Low Temperature Circulating Chiller LLTC-E14

Low Temperature Circulating Chiller LLTC-E14

Low Temperature Circulating Chiller LLTC-E14 features a circulation pump with a maximum flow of 11m³/h at 2 bar, enhancing efficiency. The system maintains stable and reliable cooling output. It offers exceptional temperature consistency over time. Its programmable settings give precise control over temperatures. Our chiller is ideal for industrial cooling applications, including laboratories, research facilities, medical storage, and high-performance equipment.

Request Quote
Temperature Range -80°C to -50°C
Temperature Control ±0.5°C
Circulation Pump Max 11m³/h 2 bar
Refrigerant R448A/R508B/R23
Cooling Capacity at -60°C 26.6 kW
Cooling Capacity at -70°C 17 kW
Power 400V 50HZ / 460V 60HZ
  • Ultra-Low Temperature Operation
  • Accurate Thermal Regulation
  • High-Flow Circulation Pump
  • Dual Voltage Compatibility
  • Heavy-Duty Cooling Output

Our Low Temperature Circulating Chiller is ideal for industrial cooling applications, including laboratories, research facilities, medical storage, and high-performance equipment, providing precise temperature control and efficient cooling for critical tasks.

Low Temperature Circulating Chiller LLTC-E14 | Temperature Range : -80°C to -50°C | Temperature Control : ±0.5°C
Low Temperature Circulating Chiller LLTC-E14 | Ultra-Low Temperature Operation | Accurate Thermal Regulation

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-A13

Low Temperature Circulating Chiller LLTC-A13

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 14m³/h 2 bar
  • Refrigerant : R410A/R134A
Low Temperature Circulating Chiller LLTC-C11

Low Temperature Circulating Chiller LLTC-C11

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 2.4m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-D14

Low Temperature Circulating Chiller LLTC-D14

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 10m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-F15
Low Temperature Circulating Chiller LLTC-F15
  • Temperature Range : -115°C to -80°C
  • Temperature Control : PLC controller, control outlet temperature, 7-inch touch screen
  • Circulation Pump Max : 40L/min 2 bar
  • Refrigerant : Mixed refrigerant 2
Low Temperature Circulating Chiller LLTC-A12
Low Temperature Circulating Chiller LLTC-A12
  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 11m³/h 2 bar
  • Refrigerant : R134A/R407C
Low Temperature Circulating Chiller LLTC-C12

Low Temperature Circulating Chiller LLTC-C12

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 3.5m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-B15

Low Temperature Circulating Chiller LLTC-B15

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 15m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-D13

Low Temperature Circulating Chiller LLTC-D13

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 7m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-E14 FAQ's
  • This chiller is ideal for industrial cooling applications in laboratories, research facilities, medical storage, high-performance equipment, and cryogenic processes. It is widely used in temperature-sensitive experiments, ensuring stable cooling for precise results. The chiller also supports medical and pharmaceutical storage by maintaining required low temperatures for preservation. Additionally, it is suitable for cooling high-performance equipment in industrial environments where temperature control is critical to operational efficiency.

  • The chiller offers precise temperature control with an accuracy of ±0.5°C, ensuring stable and reliable cooling. This level of precision is crucial for sensitive applications, where even minor temperature fluctuations can affect outcomes. The advanced temperature regulation system helps maintain consistent cooling for long durations, ensuring that critical processes or stored materials are kept at optimal temperatures. This makes the chiller ideal for scientific research, medical storage, and high-performance industrial uses.

  • The chiller is versatile and can be integrated into various cooling systems, including both water-cooled and air-cooled configurations, depending on setup. This flexibility allows it to adapt to different environmental conditions and requirements. Whether working in a lab, industrial setting, or high-performance application, the chiller can be easily adjusted to meet the needs of specific cooling system. It provides optimal performance regardless of the cooling method used, ensuring efficient and reliable operation.

  • Yes, like all industrial equipment, regular maintenance is recommended to ensure optimal performance and extend the lifespan of the chiller. Routine checks, such as cleaning the filters, inspecting the refrigerant levels, and monitoring pump performance, are essential for keeping the system running efficiently. Regular maintenance also helps identify potential issues before they become significant problems, reducing downtime and repair costs.

  • Yes, the chiller can be customized to meet the specific needs of application, including temperature ranges, refrigerant choices, and flow rates. Customization options allow for precise adjustments based on the operational requirements of processes or environment. Whether one needs a specialized temperature control range, different refrigerant types for improved efficiency, or a higher flow rate for larger systems, the chiller can be tailored to deliver optimal performance. This flexibility makes it suitable for a wide range of industries and applications.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.