Request A Quote
Low Temperature Circulating Chiller LLTC-B12

Low Temperature Circulating Chiller LLTC-B12

Low Temperature Circulating Chiller LLTC-B12 provides 26.5 kW cooling capacity at -5°C for optimal performance. Its heavy-duty pump ensures stable circulation in demanding systems. It offers energy-efficient cooling, optimizing regulation while reducing power consumption. The industrial-grade refrigerants, R448A and R507C, support reliable low-temperature performance. Our chiller supports laboratories, pharmaceuticals, biotech, chemical manufacturing, beverage production, chip cooling, air systems, refrigeration, and industrial processes.

Request Quote
Temperature Range -25°C to 30°C
Temperature Control ±0.5°C
Circulation Pump Max 6m³/h 2 bar
Refrigerant R448A/R507C
Cooling Capacity at -5°C 26.5 kW
Cooling Capacity at -15°C 16.2 kW
Power 400V 50HZ / 460V 60HZ
  • Industrial-Grade Refrigerants
  • Stable Temperature Maintenance
  • High Ambient Performance
  • Reliable Cooling Capacity
  • Durable Component Build

Our Low Temperature Circulating Chiller supports critical operations across laboratories, pharmaceuticals, biotech, chemical manufacturing, beverage production, chip cooling, experimental labs, air systems, refrigeration zones, and process-based industrial setups.

Low Temperature Circulating Chiller LLTC-B12 | Temperature Control : ±0.5°C | Circulation Pump Max : 6m³/h 2 bar
Low Temperature Circulating Chiller LLTC-B12 | High Ambient Performance | Reliable Cooling Capacity

Models of Low Temperature Circulating Chillers

Labtron Low Temperature Circulating Chillers offer precise temperature control and reliable cooling for laboratory, industrial, and research applications. Their advanced refrigeration systems ensure consistent low-temperature circulation. These chillers feature high-quality components, intuitive controls, and durable construction for efficient thermal management. They operate reliably under varying load conditions, even in continuous or high-demand use. Our chillers are ideal for cooling rotary evaporators, distillation systems, and spectroscopy instruments.

Low Temperature Circulating Chiller LLTC-A12

Low Temperature Circulating Chiller LLTC-A12

  • Temperature Range : 5°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 11m³/h 2 bar
  • Refrigerant : R134A/R407C
Low Temperature Circulating Chiller LLTC-B14

Low Temperature Circulating Chiller LLTC-B14

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 15m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-C11

Low Temperature Circulating Chiller LLTC-C11

  • Temperature Range : -45°C to 20°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 2.4m³/h 2 bar
  • Refrigerant : R448A
Low Temperature Circulating Chiller LLTC-H11
Low Temperature Circulating Chiller LLTC-H11
  • Temperature Range : -40°C to 90°C
  • Temperature Control : ±0.3°C
  • Circulation Pump Max : 35L/min 2 bar
  • Refrigerant : R-448A/R507C
Low Temperature Circulating Chiller LLTC-E11
Low Temperature Circulating Chiller LLTC-E11
  • Temperature Range : -80°C to -50°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 3.4m³/h 2 bar
  • Refrigerant : R448A/R508B/R23
Low Temperature Circulating Chiller LLTC-B15

Low Temperature Circulating Chiller LLTC-B15

  • Temperature Range : -25°C to 30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 15m³/h 2 bar
  • Refrigerant : R448A/R507C
Low Temperature Circulating Chiller LLTC-D14

Low Temperature Circulating Chiller LLTC-D14

  • Temperature Range : -60°C to -30°C
  • Temperature Control : ±0.5°C
  • Circulation Pump Max : 10m³/h 2 bar
  • Refrigerant : R448A/R23
Low Temperature Circulating Chiller LLTC-G10

Low Temperature Circulating Chiller LLTC-G10

  • Temperature Range : 5°C to 90°C
  • Temperature Control : PLC controller, control the water tank outlet temperature
  • Temperature Control Accuracy : ±0.3°C
  • Circulation Pump Max : 20L/min 2 bar
Low Temperature Circulating Chiller LLTC-B12 FAQ's
  • The Low Temperature Circulating Chiller is designed to meet the needs of rigorous lab and industrial environments through its heavy-duty pump and reliable low-temperature output. It maintains precise thermal stability with ±0.5°C accuracy, making it ideal for sensitive processes. Built with durable components, the chiller ensures uninterrupted operation even under continuous use. Its use of industrial-grade refrigerants supports consistent cooling performance under high load, while the energy-efficient design helps minimize operational costs over time.

  • Yes, the Low Temperature Circulating Chiller is engineered for low-noise operation, making it ideal for noise-sensitive environments such as laboratories and research facilities. Its sound-dampening construction ensures minimal disruption during use. This quiet performance allows it to be placed closer to work areas without affecting focus or communication. Combined with its efficient cooling, the chiller offers both comfort and functionality in controlled environments.

  • Yes, the Low Temperature Circulating Chiller is equipped with stable temperature control and offers ±0.5°C accuracy, ensuring reliable and consistent performance over extended periods. Its high-performance pump and efficient cooling system work together to maintain precise temperature regulation, even during prolonged operations. This makes it suitable for applications where continuous, stable temperatures are critical. Whether used in laboratories or industrial processes, the chiller delivers unwavering reliability over time.

  • The Low Temperature Circulating Chiller is designed to perform effectively under high ambient conditions, supporting continuous operation without the risk of overheating. Its robust construction allows it to maintain optimal cooling even in demanding environments with fluctuating temperatures. This capability makes it ideal for industrial settings where environmental conditions can vary. Additionally, its efficient cooling system ensures stable performance regardless of external temperature changes, maximizing its reliability in diverse conditions.

  • The Low Temperature Circulating Chiller features a circulation pump that provides a maximum flow rate of 6 m³/h at 2 bar pressure, ensuring robust fluid movement and optimal cooling performance. This high-efficiency pump is designed to handle demanding applications, maintaining a consistent flow even under high load. The pump’s durability and performance ensure reliable operation in both laboratory and industrial settings, contributing to the chiller's overall stability and efficiency in long-term use.

Post your question?

Our experts are here to help!

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.