Request A Quote
Nucleic Acid Extraction System LNES-B22

Nucleic Acid Extraction System LNES-B22

Labtron Nucleic Acid Extraction System LNES-B22 supports high-throughput processing with a sample capacity of 96 and volumes ranging from 20 to 1000 µl. It features a robust 10.1-inch touch screen with a windows control system for seamless operation. The system is equipped with advanced cross-contamination prevention features, including an aerosol prevention fan and UV sterilization module. Its innovative four-dimensional integrated movement and self-adaptive vibration amplitude ensure effective extraction. Our extraction system provides a safe and efficient nucleic acid extraction in high-volume settings.
Nucleic Acid Extraction System LNES-B22
Nucleic Acid Extraction System LNES-B22
Request Quote
Capacity 96 samples
Sample Volume 20 Sample to1000 µl
Recommended Volume 200 to 400 µl
Extraction Difference Between Wells ≤ 1%
Matching Reagent 96-Deep Well Plate prepackage reagent
Magnetic Bead Recovery ≥ 98%
Temperature Control Range Room temperature to 80°C
Working Temperature 10℃ to 30℃
Extraction Method Magnetic rod
Operation Interface 10.1-inch touch screen
Operation Mode Built-in Windows control system
Data Interface USB
Power Supply 220 VAC 50 Hz
Dimensions (W × D × H) 805 × 640 × 721 mm
Weight 140 kg
  • Replaceable 24-flux module option
  • Cycle binding
  • Adjustable multi-gear vibration speed
  • Liquid drip prevention tray
  • Flexible to create, edit and delete program
Our Nucleic Acid Extraction System is widely used in research laboratories, clinical diagnostics, and biotechnology facilities for the isolation and purification of DNA and RNA from various biological samples.

Models of Nucleic Acid Extraction System

Labtron Nucleic Acid Extraction System offer highly versatile magnetic-particle processing for high-throughput extraction. They efficiently isolate nucleic acid from whole blood, tissue, cells, plants, and viruses. The Extractor features a constant temperature function for optimal reaction speed and an extraction kit for reliable results. They have a user-friendly touchscreen, a built-in UV lamp, and ample data storage capacity. Our durable Nucleic Acid Extraction System is ideal for applications in diagnostic kits and research laboratories.

Nucleic Acid Extraction System LNES-B10

Nucleic Acid Extraction System LNES-B10

  • Sample Capacity : 32 samples
  • Processing Volume : 20 to 1000 µl
  • Extraction Method : Magnetic Beads
  • Extraction Time : 15 to 60 mint
Nucleic Acid Extraction System LNES-B20

Nucleic Acid Extraction System LNES-B20

  • Sample Volume : 20 µl to1000 µl
  • Sample Capacity : 16 samples
  • Extraction Difference Between Wells : CV ≤ 5%
  • Temperature Control Range : Room temperature to 120℃
Nucleic Acid Extraction System LNES-B21

Nucleic Acid Extraction System LNES-B21

  • Sample Capacity : 32 samples
  • Sample Volume : 20 µl to 1000 µl
  • Temperature Control Range : Room temperature +5℃ to 125℃
  • Extraction Method : Magnetic rod
Nucleic Acid Extraction System LNES-A11
Nucleic Acid Extraction System LNES-A11
  • Sample Capacity : 32 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 20 µl to 1000 µl
  • Sample Throughput : 1 to 32
Nucleic Acid Extraction System LNES-B23
Nucleic Acid Extraction System LNES-B23
  • Sample Capacity : 96 samples
  • Sample Volume : 20 to1000 µl
  • Recommended Volume : 200 to 400 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-C11

Nucleic Acid Extraction System LNES-C11

  • Sample Volume : 1 to 32 samples
  • Working Volume : 20 μL to 1000 μL
  • Plate Types : 96 Deep well plates
  • Difference Between Extraction Holes : CV up to 5%
Nucleic Acid Extraction System LNES-B11

Nucleic Acid Extraction System LNES-B11

  • Sample Capacity : 96 well
  • Sample Volume : 20 µl to 1000 µl
  • Extraction Time : 15 to 60 mints
  • Storage : >1000
Nucleic Acid Extraction System LNES-A12

Nucleic Acid Extraction System LNES-A12

  • Sample Capacity : 48 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 20 µl to 1000 µl
  • Sample Throughput : 1 to 48

Nucleic Acid Extraction System:
Nucleic Acid Extraction System LNES-B10, Nucleic Acid Extraction System LNES-B20, Nucleic Acid Extraction System LNES-B21, Nucleic Acid Extraction System LNES-A11, Nucleic Acid Extraction System LNES-B23, Nucleic Acid Extraction System LNES-C11, Nucleic Acid Extraction System LNES-B11, Nucleic Acid Extraction System LNES-A12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.