info@labtron.com +44 2080 043608
Nucleic Acid Extraction System LNES-A12

Nucleic Acid Extraction System LNES-A12

Nucleic Acid Extraction System LNES-A12 is a completely automated, compact system for isolating DNA and RNA from a variety of samples, including whole blood, tissue, cells, plants, and viruses. This compact equipment can handle 48 samples up to 500 µl in a single run, maximizing laboratory bench space. The method uses an ultra-thin polymer membrane for effective nucleic acid capture, allowing for isolation of high quality, high yield RNA or DNA. This instrument is a complete kit that includes everything a lab needs to automate high-speed purification.

Request Quote
Sample Capacity 48 samples
Sample Volume 20 to 500 µl
Working Volume 20 µl to 1000 µl
Sample Throughput 1 to 48
Extraction Time 15 to 40 min/round
Extraction Method Magnetic Bead Recovery
Magnetic Bead Recovery > 98%
Extracting the difference between holes CV ≤ 3%
Heating Temperature 8 independent heating modules, customize lysis and elution temperature
Oscillating Mixing Low, medium and high 3 gears are adjustable and fluctuation range can be adjusted with the reagent volume
Reagent Type Magnetic bead open platform
Internal Program Can store up to > 100 groups of programs
Built-in Air Duct Yes
UV Radiation Yes
Package Size (W×D×H) 700×520×750 mm
Gross Weight 80 kg
  • Convenient throughput up to 32 samples in 15 – 40 mints
  • 7-inch touch screen, easy to use console
  • UV dis-infection function
  • Archival quality DNA or RNA
  • Automatic control system
  • User defined cracking and elution temperature
  • Fast purification process
  • Reproducibility with magnetic rods
  • Plate re-orientation
  • Lidding and de-lidding
  • Graphical process editor
  • Free programming to meet the different needs of the reagent

This device is compatible with PCR diagnostics kits and also has requirement in several fields such as Forensic Samples, Sequencing, Cloning, Routine sample preparation, Genetic screening, Microbiology testing and Plant molecular biology research.

Compare Models

Model Sample Capacity Sample Volume Working Volume Sample Throughput Extraction Time Extraction Method Magnetic Bead Recovery Extracting the difference between holes Heating Temperature Oscillating Mixing Reagent Type Internal Program Built-in Air Duct UV Radiation Package Size (W×D×H) Gross Weight
LNES-A10 1 to 8 samples 20 to 500 µl 200 to 1000 µl - 15 to 40 minutes Magnetic beads ≥ 98% - - - - - - - 385×370×395 mm 14.5 kg
LNES-A11 32 samples 20 to 500 µl 20 µl to 1000 µl 1 to 32 15 to 40 min/round Magnetic Bead Recovery > 98% CV ≤ 3% 8 independent heating modules, customize lysis and elution temperature Low, medium and high 3 gears are adjustable and fluctuation range can be adjusted with the reagent volume Magnetic bead open platform Can store up to > 100 groups of programs No Yes 580×510×700 mm 51 kg
LNES-A12 48 samples 20 to 500 µl 20 µl to 1000 µl 1 to 48 15 to 40 min/round Magnetic Bead Recovery > 98% CV ≤ 3% 8 independent heating modules, customize lysis and elution temperature Low, medium and high 3 gears are adjustable and fluctuation range can be adjusted with the reagent volume Magnetic bead open platform Can store up to > 100 groups of programs Yes Yes 700×520×750 mm 80 kg
LNES-A13 1 to 96 20 µl to 1000 µl - - 15 to 40 mints Magnetic Bead Recovery ≥ 98% - - - Open system for magnetic bead method - - - 910×670×780 mm 95 kg
LNES-B10 32 samples - - - 15 to 60 mint Magnetic Beads ≥ 98% - - Vertical Mixing, low, medium and high 3 gears adjustable - - - - 538×538×750 mm 37 kg
LNES-B11 96 well 20 µl to 1000 µl - - 15 to 60 mints - ≥ 98% - - - - - - - 1138×733×1028 mm 130 kg