Nucleic Acid Extraction System LNES-A13

Nucleic Acid Extraction System LNES-A13

Nucleic Acid Extraction Device LNES-A13 is a fully automated system for extracting and purifying DNA from a variety of sources. This process can handle a large number of samples each day in a matter of minutes and provide quick, consistent, and reproducible results. This compact gadget can handle 96 large volume samples up to 1000 l in a single run. It is a popular and effective automated sample preparation system.
Request Quote
Sample Capacity 1 to 96
Sample Volume 20 µl to 1000 µl
Extraction Time 15 to 40 mints
Extraction Method Magnetic Bead Recovery
Operating Temperature RT to 120°C
Magnetic Bead Recovery ≥ 98%
Extracting Difference Holes CV ≤ 3%
Product Purity A260/A280 DNA ≥ 1.7 – 2.0; RNA ≥ 1.8-2.1
Shock Mixing Adjustable Speed (1 to 3)
Reagent Type Open system for magnetic bead method
Program Storage ≥ 100 groups
Display 10.1 inch screen
Dis-infection Method UV Light, Aerosol Adsorption
Power Consumption 500W
Power Supply AC 100V – 240V 50/60Hz
External Size (W×D×H) 770×530×540 mm
Package Size (W×D×H) 910×670×780 mm
Gross Weight 95 kg
  • High purity of product
  • Fully automated and easy to operate
  • Optimization of extraction process with professional extraction kit
  • Large capacity program
  • Constant temperature function to ensure best reaction speed during the purification process
  • Friendly operation interface
  • Portable, light-weight and durable
  • Versatile liquid handling options
  • Built-in touch screen
  • Automated DNA/RNA extraction
  • Fast purification process
  • Reproducibility with magnetic rods
  • Plate re-orientation
These devices are used in various fields such as, Genetic Screening, Transgene Screening, Paternity Testing, Forensic Testing, Microbiology Testing, Plant molecular biology research and also for Genomic DNA and RNA extraction from whole blood, tissues, and cultured cells etc.

Models of Nucleic Acid Extraction System

Labtron Nucleic Acid Extraction System offer highly versatile magnetic-particle processing for high-throughput extraction. They efficiently isolate nucleic acid from whole blood, tissue, cells, plants, and viruses. The Extractor features a constant temperature function for optimal reaction speed and an extraction kit for reliable results. They have a user-friendly touchscreen, a built-in UV lamp, and ample data storage capacity. Our durable Nucleic Acid Extraction System is ideal for applications in diagnostic kits and research laboratories.

Nucleic Acid Extraction System LNES-B20

Nucleic Acid Extraction System LNES-B20

  • Sample Volume : 20 µl to1000 µl
  • Sample Capacity : 16 samples
  • Extraction Difference Between Wells : CV ≤ 5%
  • Temperature Control Range : Room temperature to 120℃
Nucleic Acid Extraction System LNES-B10

Nucleic Acid Extraction System LNES-B10

  • Sample Capacity : 32 samples
  • Processing Volume : 20 to 1000 µl
  • Extraction Method : Magnetic Beads
  • Extraction Time : 15 to 60 mint
Nucleic Acid Extraction System LNES-B22

Nucleic Acid Extraction System LNES-B22

  • Capacity : 96 samples
  • Sample Volume : 20 Sample to1000 µl
  • Recommended Volume : 200 to 400 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-B21
Nucleic Acid Extraction System LNES-B21
  • Sample Capacity : 32 samples
  • Sample Volume : 20 µl to 1000 µl
  • Temperature Control Range : Room temperature +5℃ to 125℃
  • Extraction Method : Magnetic rod
Nucleic Acid Extraction System LNES-A12
Nucleic Acid Extraction System LNES-A12
  • Sample Capacity : 48 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 20 µl to 1000 µl
  • Sample Throughput : 1 to 48
Nucleic Acid Extraction System LNES-A10

Nucleic Acid Extraction System LNES-A10

  • Sample Capacity : 1 to 8 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 200 to 1000 µl
  • Extraction Time : 15 to 40 minutes
Nucleic Acid Extraction System LNES-C11

Nucleic Acid Extraction System LNES-C11

  • Sample Volume : 1 to 32 samples
  • Working Volume : 20 μL to 1000 μL
  • Plate Types : 96 Deep well plates
  • Difference Between Extraction Holes : CV up to 5%
Nucleic Acid Extraction System LNES-B24

Nucleic Acid Extraction System LNES-B24

  • Sample Capacity : 24 samples
  • Sample Volume : 50 to 5000 µl
  • Recommended Volume : 2000 to 5000 µl
  • Extraction Difference Between Wells : ≤ 1%

Nucleic Acid Extraction System:
Nucleic Acid Extraction System LNES-B20, Nucleic Acid Extraction System LNES-B10, Nucleic Acid Extraction System LNES-B22, Nucleic Acid Extraction System LNES-B21, Nucleic Acid Extraction System LNES-A12, Nucleic Acid Extraction System LNES-A10, Nucleic Acid Extraction System LNES-C11, Nucleic Acid Extraction System LNES-B24, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.