Request A Quote
Nucleic Acid Extraction System LNES-A10

Nucleic Acid Extraction System LNES-A10

Nucleic Acid Extraction system LNES-A10 is fully automated compact system designed to efficiently isolate DNA and RNA from multiple sample types, including whole blood, tissue, cells, plants and viruses. This compact unit can process 8 samples up to 500 µL in a single run making efficient use of laboratory bench space. The most significant advantage is the reliability of the isolated nucleic acid and the technology utilizes an ultra-thin polymer membrane for efficient capture of nucleic acids, allowing for isolation of high quality, high yield RNA or DNA.
Request Quote
Sample Capacity 1 to 8 samples
Sample Volume 20 to 500 µl
Working Volume 200 to 1000 µl
Extraction Time 15 to 40 minutes
Extraction Method Magnetic beads
Magnetic Bead Recovery ≥ 98%
Open System Apply to different magnetic beads reagents
Sample Lysis Controlled temperature function
Product Purity A260/A280 DNA ≥ 1.7–2.0; RNA ≥ 1.8–2.1
Power Supply AC 100V–240V, 50-60Hz
External Size (W×D×H) 285×280×295 mm
Package Size (W×D×H) 385×370×395 mm
Net Weight 7.5 kg
Gross Weight 14.5 kg
  • Automated DNA/RNA extraction
  • System uses pre-filled cartridges that can run independently
  • High purity of product
  • Fully automated and easy to operate
  • High throughput, can process 1-96 samples at a single stretch
  • Optimization of extraction process with professional extraction kit
  • Large capacity program
  • Constant temperature function to ensure best reaction speed during the purification process
  • Friendly operation interface
  • Portable, light-weight and durable
  • Versatile liquid handling options
  • Built-in touch screen
This device is compatible with PCR diagnostics kits and also has requirement in several fields such as Forensic Samples, Sequencing, Cloning, Routine sample preparation, Genetic screening, Microbiology testing and Plant molecular biology research.

Models of Nucleic Acid Extraction System

Labtron Nucleic Acid Extraction System offer highly versatile magnetic-particle processing for high-throughput extraction. They efficiently isolate nucleic acid from whole blood, tissue, cells, plants, and viruses. The Extractor features a constant temperature function for optimal reaction speed and an extraction kit for reliable results. They have a user-friendly touchscreen, a built-in UV lamp, and ample data storage capacity. Our durable Nucleic Acid Extraction System is ideal for applications in diagnostic kits and research laboratories.

Nucleic Acid Extraction System LNES-B21

Nucleic Acid Extraction System LNES-B21

  • Sample Capacity : 32 samples
  • Sample Volume : 20 µl to 1000 µl
  • Temperature Control Range : Room temperature +5℃ to 125℃
  • Extraction Method : Magnetic rod
Nucleic Acid Extraction System LNES-B22

Nucleic Acid Extraction System LNES-B22

  • Capacity : 96 samples
  • Sample Volume : 20 Sample to1000 µl
  • Recommended Volume : 200 to 400 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-B30

Nucleic Acid Extraction System LNES-B30

  • Sample Capacity : 16
  • Sample Volume : 200 to 1200 µl
  • Elution Volume : 60 µl/ 100 µl/ 150 µl/ 200 µl/ 300 µl
  • Processing Time : 30 to 70 min
Nucleic Acid Extraction System LNES-C11
Nucleic Acid Extraction System LNES-C11
  • Sample Volume : 1 to 32 samples
  • Working Volume : 20 μL to 1000 μL
  • Plate Types : 96 Deep well plates
  • Difference Between Extraction Holes : CV up to 5%
Nucleic Acid Extraction System LNES-A11
Nucleic Acid Extraction System LNES-A11
  • Sample Capacity : 32 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 20 µl to 1000 µl
  • Sample Throughput : 1 to 32
Nucleic Acid Extraction System LNES-B24

Nucleic Acid Extraction System LNES-B24

  • Sample Capacity : 24 samples
  • Sample Volume : 50 to 5000 µl
  • Recommended Volume : 2000 to 5000 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-B11

Nucleic Acid Extraction System LNES-B11

  • Sample Capacity : 96 well
  • Sample Volume : 20 µl to 1000 µl
  • Extraction Time : 15 to 60 mints
  • Storage : >1000
Nucleic Acid Extraction System LNES-B10

Nucleic Acid Extraction System LNES-B10

  • Sample Capacity : 32 samples
  • Processing Volume : 20 to 1000 µl
  • Extraction Method : Magnetic Beads
  • Extraction Time : 15 to 60 mint

Nucleic Acid Extraction System:
Nucleic Acid Extraction System LNES-B21, Nucleic Acid Extraction System LNES-B22, Nucleic Acid Extraction System LNES-B30, Nucleic Acid Extraction System LNES-C11, Nucleic Acid Extraction System LNES-A11, Nucleic Acid Extraction System LNES-B24, Nucleic Acid Extraction System LNES-B11, Nucleic Acid Extraction System LNES-B10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.