Conductivity: Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 3 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
Temperature: Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient: Linear
Conductivity: Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
TDS: TDS range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
Temperature: Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
Temperature compensation: 0 to 100 °C, Manual or Automatic
Conductivity: Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
Salinity: Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1
Temperature: Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
Temperature compensation: 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Conductivity: Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
TDS: TDS range0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
Salinity: Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1
Resistivity: Resistivity range0.00 to 20 MΩResistivity accuracy±1% F.SResistivity resolution0.01, 0.1, 1
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608