Portable Conductivity Meter LPCM-A10 is adapted for measuring quality of water on parameter such as conductivity and TDS. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing and for research purpose. It is reliable and user friendly.
Request Quote
Conductivity
Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy±0.5% F.S
Conductivity calibration points1 to 3 points
Conductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution0.001, 0.01, 0.1, 1
Temperature
Temperature measuring range0 105 °C, 32 to 221 °F
Temperature measuring accuracy± °0.5 C, ± 0.9 °F
Temperature calibration points1 point
Temperature resolution0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Reference temperature 25 °C
Stability conditions Low or high
Cell constant K= 0.1, 1, 10 or custom
Calibration due 1 to 31 days or off
Memory 100 data sets
Data hold Manual or auto-end point
Connector 6 pin mini plug
Power Control Manual or Automatic (10, 20 or 30 minutes after last key pressed)
Power 3 × 1.5 V AA batteries or DC 5 V power adapter
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 300 g
  • Common features
  • Calibration due reminder informs operator to calibrate the meter regularly
  • Stability indicator displays the status of current measurement
  • Auto hold function freezes stable, final readings for better viewing and recording
  • 1 to 3 points push button calibration to automatically identify calibration solutions
  • Selectable temperature units (°C or °F) for different application requirements
  • Expanded memory stores and recalls up to 500 readings
  • Calibration report provides details of calibration standard and cell constant
  • Help message as an operational guide, helps users for quick access to the parameters
  • Reset function automatically resumes all settings back to factory default options
  • Store data is transferrable into computer via USB communication interface
  • Conductivity / Temperature
  • Conductivity: 1 to 3 point calibration with automatically identification of calibration solutions
  • Temperature: Can select cell constant (0.1/1/10) and normalization temperature 25°C
  • Linear compensation improves the measurement accuracy
Used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.
Number of accessories Accessories name
1 Conductivity electrode (range: 10 µS/cm to 10 mS/cm)
2 Temperature probe
3 Standard calibration solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm)
4 Carrying case
Number of accessories Accessories name
1 Conductivity electrode for general application
2 Conductivity electrode (K= 0.1): Suitable for measuring the low conductivity liquids ( <10 µS/cm ) for pure water
3 Conductivity electrode (K= 10): Suitable for measuring the high conductivity liquids ( >20 mS/cm ) for sea water

Models of Portable Conductivity Meter

Labtron Portable Conductivity Meters are compact tools used to measure conductivity in diverse field environments. They feature wide measuring ranges and high accuracy to ensure consistent and dependable performance outdoors. These meters support multi-point calibration and automatic buffer recognition for enhanced measurement reliability. Their user-friendly interface, backlit LCD, and auto temperature compensation enable smooth on-site operation. Our Portable Conductivity Meters are perfect for environmental monitoring, industrial water testing, and field analysis tasks.

Portable Conductivity Meter LPCM-C10

Portable Conductivity Meter LPCM-C10

  • Conductivity Measuring Range : 0.00 to 19.99 μS/cm20.0 to 199.9 μS/cm 200 to 1999 S/cm2.00 to 19.99 mS/cm20.0 to 199.9 mS/cmTDS: 0 to 100 g/LSalinity: 0 to 100 pptResistivity: 0 to 100 MΩ∙cm
  • Conductivity Resolution : 0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
  • Conductivity Accuracy : ± 1.0% F S, Overall: ± 1.5% F S
  • Conductivity Temperature Compensation : 0 to 100℃ (Auto/manual)
Portable Conductivity Meter LPCM-B10

Portable Conductivity Meter LPCM-B10

  • Conductivity Measurement Range : 0.00 μS/cm to 100 mS/cm (0.0 to 2.0 μS/cm., 0.2 to 20.0 μS/cm, 0.00, 2 to 10,000 μS/cm, 10,000 to 100,000 μS/cm)
  • Conductivity Accuracy : ± 1.0% F.S
  • Stability : ±0.7% F.S / 3h
  • Temperature Compensation : Manual (15℃ to 35℃)
Portable Conductivity Meter LPCM-A12

Portable Conductivity Meter LPCM-A12

  • Conductivity : Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • Salinity : Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1
  • Temperature : Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
  • Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Portable Conductivity Meter LPCM-A11
Portable Conductivity Meter LPCM-A11
  • Conductivity : Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • TDS : TDS range0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
  • Temperature : Temperature measuring range0 105 °C, 32 to 221 °FTemperature measuring accuracy± °0.5 C, ± 0.9 °FTemperature calibration points1 pointTemperature resolution0.1 °C, 0.1 °F
  • Temperature compensation : 0 to 100 °C, Manual or Automatic
Portable Conductivity Meter LPCM-A13
Portable Conductivity Meter LPCM-A13
  • Conductivity : Conductivity measurement range0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cmConductivity accuracy±0.5% F.SConductivity calibration points1 to 5 pointsConductivity calibration solutions10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or CustomConductivity resolution0.001, 0.01, 0.1, 1
  • TDS : TDS range0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)TDS accuracy±1 % F.STDS factor0.01 to 1.00 (Default 0.5)TDS resolution0.01, 0.1, 1
  • Salinity : Salinity range0.00 to 80.00 ppt, 0.00 to 42.00 psuSalinity accuracy±1% F.SSalinity measurement modesPractical Salinity (psu) or Natural Seawater (ppt)Salinity resolution0.01, 0.1, 1
  • Resistivity : Resistivity range0.00 to 20 MΩResistivity accuracy±1% F.SResistivity resolution0.01, 0.1, 1

Portable Conductivity Meter:
Portable Conductivity Meter LPCM-C10, Portable Conductivity Meter LPCM-B10, Portable Conductivity Meter LPCM-A12, Portable Conductivity Meter LPCM-A11, Portable Conductivity Meter LPCM-A13, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608