Labtron Portable Multi Parameter Water Quality Meter offer precise water quality analysis with multi-parameter measurement capabilities. These meters measure pH, ORP, conductivity, TDS, dissolved oxygen, and absorbance with high accuracy. Their user-friendly interface ensures quick calibration and easy operation. They feature multiple calibration points for reliable results. These devices include automatic temperature compensation for accurate readings. Our multi-parameter water quality meters provide dependable performance for diverse water analysis applications.
pH Measurement Range: (-2.000) to 20.000 pH
pH Accuracy: ± 0.002 pH
pH Calibration Points: 1 - 5 points
pH Calibration Solutions: USA, NIST, DIN or user defined
pH mode: pH measurement range (-2.000) to 20.000 pH pH accuracy ± 0.002 pH pH calibration points 1 to 5 points pH calibration solutions USA, NIST, DIN or user defined
ORP measurement: ORP measurement range -1999.9 to 1999.9 mV ORP accuracy ±0.2 mV ORP calibration points 1 point ORP calibration solutions mV & relative mV
Conductivity measurement: Conductivity measurement range 0 to 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm Conductivity accuracy ± 0.5 % F.S. Conductivity calibration points 1 to 5 points Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm Temperature coefficient 0.0 to 10.0 % / °C Compensation modes Linear or pre water Cell constant K = 0.1, 1, 10 or user-defined Normalization temperature 20 °C or 25 °C
TDS measurement: TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting) TDS accuracy ± 1 % F.S. TDS factor 0.1 - 1.0 (default 0.5)
pH mode: pH measurement range(-2.000) to 20.000 pHpH accuracy± 0.002 pHpH calibration points1 - 5 pointspH calibration solutionsUSA, NIST, DIN or user defined
ORP measurement: ORP measurement range-1999.9 to 1999.9 mVORP accuracy±0.2 mVORP calibration points1 pointORP calibration solutionsmV & relative mV
Conductivity measurement: Conductivity measurement range0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cmConductivity accuracy± 0.5 % F.S.Conductivity calibration points1 - 5 pointsConductivity calibration solutions10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cmTemperature coefficient0.0 to 10.0 % / °CCompensation modesLinear or pre waterCell constantK = 0.1, 1, 10 or user-definedNormalization temperature20 °C or 25 °C
TDS measurement: TDS range0-100 ppt. (max. 200 ppt., depending on factor setting)TDS accuracy± 1 % F.S.TDS factor0.1 - 1.0 (default 0.5)
pH mode: pH measurement range(-2.000) to 20.000 pHpH accuracy± 0.002 pHpH calibration points1 - 5 pointspH calibration solutionsUSA, NIST, DIN or user defined
ORP measurement: ORP measurement range-1999.9 to 1999.9 mVORP accuracy±0.2 mVORP calibration points1 pointORP calibration solutionsmV & relative mV
Dissolved oxygen: DO concentration range0.00 to 20.00 mg/LDO accuracy± 0.2 mg/LCalibration points1 - 2 pointsPressure correction60.0 to 112.5 kPa, 450 - 850 mmHgSalinity correction0 to 50 g/L% Saturation of Oxygen0.0 to 200.0 %Accuracy± 2.0 %
Temperature compensation: 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Absorbance Detection Range: 0 to 3Abs
Absorbance Resolution: 0.001Abs
Optical Path Stability: ≤ ±0.005Abs/30min
Operation Repeatability: ≤ ±0.01Abs
pH Range: -2.000 to 20.000 pH
pH Resolution: 0.1, 0.01, 0.001 pH
pH Accuracy: ± 0.002 pH
pH Calibration Points: Up to 8
pH Electrode Type: Triple compound pH electrode
pH Measurement Principle: Glass electrode method
pH Measuring Range: 0 to 14
pH Accuracy: ≤ ±0.05 pH
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom