Reflectivity Tester LRFT-C10 is designed to measure the spectral reflectance with a wavelength range of 360 nm to 1100nm. It is suitable for tiny, ultra-thin, and curved samples that cannot be measured by conventional spectrophotometers. The tester is capable of eliminating interference from the reflected light from the back of the sample. Additionally, it supports XY chromaticity diagrams and Lab color measurements based on spectral reflectance. Our Reflectivity Tester is widely used in precision optical analysis, especially for characterizing the spectral reflectance of miniature, curved, and transparent samples.

Request Quote
Type Microscopic
Wavelength Range 360 to 1100 nm
Spot Size 60  µm
Spectral Resolution 1 nm, 5 nm
Wavelength Accuracy ±0.5 nm
Measurement Method Comparison with reference sample
Measurement Error Up to ±2% (0 to 100%)
Objective Lens 10x half-width objective lens
Sample Curvature Compatibility -1R to ∞ to +1R to ∞
Observation Method Eyepiece + CCD camera
Reflection Test Light Source Halogen lamp 12V 100VA
Focus Light Source 6000K LED
Reflectance Ratio Range 0 to 100%
Integration Measurement Time Up to 1 second to 5 seconds
Repeatability Error Up to 0.5.%
PC Interface USB mode
Power Supply AC 210 to 240V 50/60 Hz 200 VA
  • High-speed spectrophotometry mechanism
  • Small spot focus
  • Microscopic reflectivity test
  • Plane grating mechanism
  • Color difference comparison

Our Reflectivity Tester LRFT-C10 accurately measures spectral reflectance and coating uniformity, even on complex surfaces like lenses. Its ability to eliminate back reflection and focus on microscopic spots ensures precision in evaluating transparent materials. The system supports colorimetric analysis, making it valuable in optical quality control and R&D. It is ideal for industries requiring high-accuracy reflectance and color measurement at the microscale.

Models of Reflectivity Tester

Labtron offers a wide range of Reflectivity Testers that are designed to measure the reflectivity and reflectivity curves of various objects. They are also analyzing the color characteristics of the materials and enabling the simultaneous detection. Their compliance with various national standards makes them reliable for industrial and laboratory-grade testing environments. They adopt the integrating sphere method, allowing customized measurement angles based on specific application needs. Our Testers are widely applied across industries such as electronics, automotive, optics, materials science, and display manufacturing.

Reflectivity And Transmittance Tester LRFT-B10

Reflectivity And Transmittance Tester LRFT-B10

  • Wavelength Range : 360 to 1000 nm
  • Measurement Function : Transmission/Reflection
  • Illumination Receiving Conditions : Transmissions: Vertical illumination/vertical receivingReflection: 8° illumination / vertical receiving (integrating sphere method)
  • Spot Size : Transmission: adjustable diameter Φ 0.1 to 5 mmReflection: adjustable diameter 1 to 5mm
Reflectivity Tester LRFT-A10

Reflectivity Tester LRFT-A10

  • Measurement Function : Reflectance/ Reflectance spectral curve/ Color
  • Wavelength Range : 380 to 1000 nm
  • Detector : 2048 array photoelectric detector
  • Illumination/ Reception Conditions : 8-degree illumination/ Vertical reception (integrating sphere method)
Automobile Rearview Mirror Reflectivity Tester LRFT-D12

Automobile Rearview Mirror Reflectivity Tester LRFT-D12

  • Wavelength Range : 900 to 1700 nm
  • Reflectivity Measurement Range : 0 to 100%
  • Measurable Parameters : Wavelength reflectivity, average reflectivity, reflectivity spectrum curve, reflectivity change curve over time, material spectrum component analysis etc.
  • Measurement Interval : 1 nm
Automobile Rearview Mirror Reflectivity Tester LRFT-D10
Automobile Rearview Mirror Reflectivity Tester LRFT-D10
  • Wavelength Range : 250 to 800 nm
  • Reflectivity Measurement Range : 0 to 100%
  • Measurable Parameters : Wavelength reflectivity, average reflectivity, reflectivity spectrum curve, reflectivity change curve over time, etc.
  • Measurement Interval : 1 nm
Automobile Rearview Mirror Reflectivity Tester LRFT-D11
Automobile Rearview Mirror Reflectivity Tester LRFT-D11
  • Wavelength Range : 400 to 1000 nm
  • Reflectivity Measurement Range : 0 to 100%
  • Measurable Parameters : Wavelength reflectivity, average reflectivity, reflectivity spectrum curve, reflectivity change curve over time, reflective color xy, XYZ, lab, etc.
  • Measurement Wavelength Interval : 1 nm

Reflectivity Tester:
Reflectivity And Transmittance Tester LRFT-B10, Reflectivity Tester LRFT-A10, Automobile Rearview Mirror Reflectivity Tester LRFT-D12, Automobile Rearview Mirror Reflectivity Tester LRFT-D10, Automobile Rearview Mirror Reflectivity Tester LRFT-D11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.