info@labtron.com +44 2080 043608
Soil nutrient tester TSNA-A10

Soil nutrient tester TSNA-A10

Soil nutrient tester TSNA-A10 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. Its LCD touch display shows all test parameters, test results, which can be printed out using built-in printer. The optical filter present in the nutrient analyzer acts as light source, its silicon semiconductor acts as signal receiver system with 100000 hours of work life.

Request Quote
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 , Green light: ≥ 2.35 × 10-3 , Orange light: ≥ 2.13 × 10-3
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode
Moisture content rate testing range0 to 100 %
Moisture unit% (m3/m3)
Accuracy± 2 %
pH mode
pH Measurement range1 to 14 pH
pH Accuracy± 0.1
Conductivity mode
Conductivity Measurement range0.01 % to 1.00 %
Conductivity Accuracy± 5 %
Dimension 340 × 280 × 100 mm
Gross Weight 15 kg
Power supply AC 180 to 240 V, 50 Hz
  • LCD display touch control
  • Microprocessor controlled technology
  • Built-in thermal printer
  • Automatic temperature calibration system for organic phosphorous testing
  • Excellent shock resistant
  • Digital circuit programmed design

It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

Reagent as per requirement/need

Compare Models

Model Measuring range Stability Linearity error Repeatability error Wavelength range Sensitivity Moisture measure range Measurement time (for soil N, P, K) Dimension Gross Weight Power supply
TSNA-A10 0.001 to 9999 A (absorbency of light) <0.003 within 3 mins <3.0 % A (absorbency of light) <0.005 Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 , Green light: ≥ 2.35 × 10-3 , Orange light: ≥ 2.13 × 10-3 A: humidity 0 to 100 %, B: Accuracy: ±3 % ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
340 × 280 × 100 mm 15 kg AC 180 to 240 V, 50 Hz
TSNA-A11 0.001 to 9999 A (absorbency of light) <0.003 within 3 mins <3.0 % A (absorbency of light) <0.005 Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 A: humidity 0 to 100 %, B: Accuracy: ±3 % ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
340×280×100 mm - AC 180 to 240 V, 50 Hz
TSST-A10 - - - - - - - - - - -
TSWT-A10 0 to 100 kPa - - - - - - - - 15 kg -
TSHM-A10 - - - - - - - - - - Chargeable AC 100 to 240 voltage
TSHM-A11 - - - - - - - - - - Chargeable AC 100 to 240 voltage
TSMM-A10 - - - - - - - - - - 4 1.5 AAA size (UM4 )
TSMM-A11 - - - - - - - - - - 9 V battery
TSMM-A12 - - - - - - - - - - 4 1.5 AAA size (UM4 )
LSST-A10 - - - - - - - - 180 × 170 × 530 mm - 220 V/50 Hz

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2023 Labtron Equipment Ltd. All rights reserved.