info@labtron.com +44 2080 043608
Soil nutrient tester TSNA-A11

Soil nutrient tester TSNA-A11

Soil nutrient tester TSNA-A11 with microprocessor controlled technology measures nutrient values in % and gives accurate test results. The optical filter present in the nutrient analyzer acts as light source. It has attractive & durable, long lasting plate shell, large LCD display to easily view & study test parameters. With time display function, it can automatically record and save the time of sample tested.

Request Quote
Measuring range 0.001 to 9999
Stability A (absorbency of light) <0.003 within 3 mins
Linearity error <3.0 %
Repeatability error A (absorbency of light) <0.005
Wavelength range Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm
Sensitivity Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3
Moisture measure range A: humidity 0 to 100 %, B: Accuracy: ±3 %
Measurement time (for soil N, P, K) ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
Soil moisture mode
Moisture content rate testing range0 to 100 %
Moisture unit% (m3 /m3)
Accuracy± 2 %
pH mode
pH Measurement range1 to 14 pH
pH Accuracy± 0.1
Salinity mode
Salinity range0.01 % to 1.00 %
Salinity accuracy± 5 %
Dimension 340×280×100 mm
Gross weight 18 kg
Power supply AC 180 to 240 V, 50 Hz
  • Large LCD display
  • Playback function for convenient testing
  • Built –in rechargeable battery
  • Built-in thermal printer
  • 1000 groups of data storage
  • Microprocessor controlled technology

It finds best application in quantitative analysis of to N, P, K, organic matter, pH, trace elements, salinity of soil, fertilizer & other samples.

Reagent as per requirement/need

Compare Models

Model Measuring range Stability Linearity error Repeatability error Wavelength range Sensitivity Moisture measure range Measurement time (for soil N, P, K) Dimension Gross weight Power supply
TSNA-A10 0.001 to 9999 A (absorbency of light) <0.003 within 3 mins <3.0 % A (absorbency of light) <0.005 Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm, Orange light: 590 ± 2 nm Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 , Green light: ≥ 2.35 × 10-3 , Orange light: ≥ 2.13 × 10-3 A: humidity 0 to 100 %, B: Accuracy: ±3 % ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
340 × 280 × 100 mm - AC 180 to 240 V, 50 Hz
TSNA-A11 0.001 to 9999 A (absorbency of light) <0.003 within 3 mins <3.0 % A (absorbency of light) <0.005 Red light: 680 ± 2 nm, Blue light: 420 ± 2 nm, Green light: 510 ± 2 nm Red light: ≥ 4.5 × 10-5 , Blue light: ≥ 3.17 × 10-3 A: humidity 0 to 100 %, B: Accuracy: ±3 % ≤30 min
5 pcs soil samples at one time ≤50 min (including pretreatment time)
340×280×100 mm 18 kg AC 180 to 240 V, 50 Hz
TSST-A10 - - - - - - - - - 15 kg -
TSWT-A10 0 to 100 kPa - - - - - - - - - -
TSHM-A10 - - - - - - - - - 2 kg Chargeable AC 100 to 240 voltage
TSHM-A11 - - - - - - - - - 13 kg Chargeable AC 100 to 240 voltage
TSMM-A10 - - - - - - - - - 700 g 4 1.5 AAA size (UM4 )
TSMM-A11 - - - - - - - - - 700 g 9 V battery
TSMM-A12 - - - - - - - - - 700 g 4 1.5 AAA size (UM4 )
LSST-A10 - - - - - - - - 180 × 170 × 530 mm - 220 V/50 Hz