Table Top Spectrophotometer LTS- B14 features a reflectance range of 0 to 200%, ensuring accurate evaluation of standard and fluorescent surfaces. It supports barcode scanning for quickly identifying and tracking samples. The device has an advanced temperature control option that maintains stable conditions for more reliable results. Our table top spectrophotometer offers low inter-instrument error, providing uniform and consistent color readings across multiple units.
Reflectance Range | 0 to 200% |
Sphere Size | Φ154mm |
Semiband Width | 5nm |
Sensor | 256 Images Element Double Array CMOS Image Sensor |
Wavelength Ptich | 10nm |
Measurement Time | 2.4 s |
Measurement Aperature | Reflective : Φ30mm / Φ25.4mm , Φ 18mm / Φ 15mm, Φ 10mm / Φ8mm, Φ 6mm/ Φ 4mm Transmissive : Φ30mm / Φ 25.4mm |
Viewing Angle | 2° / 10° |
Optical Geometry | Reflect : D/8 Transmittance : D/0 Conforms to CIE No.15, GB/ T 3978, GB/T 18833, ISO7724/1 ASTM E1164, DIN 5033 Teil 7 |
Repeatability | Spectral reflectance :Φ 25.4mm / SCI Chromaticity Value: Φ 25.5mm / SCI |
Illuminants | D 65, A , C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30. |
Color Spaces | CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB Hunter Lab, Bxy, DIN Lab99 |
Color Difference | ΔE ab, ΔE uv, ΔE 94, ΔE cmc (2:1), ΔE ×cmc (1:1) ΔE 00, DIN Δ E99, ΔE(Hunter) |
Calorimetric Index | WI( ASTM E313, CIE/ ISO, AATCC, Hunter) YI(ASTM D1925, ASTM 313) MI (Metamerism Index ) Staining Fastness, Color Fastness, Color Strength, Opacity, 8˚ Glossiness , Gardner Index, Haze , APHA / Pt – Co Index, 555 Index, Haze (ASTM D1003) Saybolt , Color code (ASTM D1500) |
Inter- Instrument Error | Φ 25.4 mm / SCI ΔE × ab 0.12 |
Data Storage Capacity | Standard : 5000 Pcs Sample : 40000 Pcs |
Power Consumption | DC 24 V, 3A |
Dimensions ( L× W× H) | 370 × 300 × 200 mm |
Weight | 9.6 kg |
Fast Measurement Time
High Reflectance Range
Optimized Signal Processing
Quick Calibration Process
Multiple Viewing Angles
Table Top Spectrophotometer LTS-B14 is a laboratory instrument used for measuring the intensity of light absorbed by a sample at different wavelengths. It is applied in cosmetics and pharma industry for precise color analysis of tablets, creams, and to maintain product quality.
Power Adapter | 1 |
USB Cable | 1 |
Transmissive Test Component | 1 |
Transmission Black Baffle | 1 |
Sample Holder | 1 |
Micro Aperture (4mm) | 1 |
Standard Calibration Board | 1 |
Black Calibration Cavity | 1 |
Download catalog for
Table Top Spectrophotometer LTS-B14 Catalog
Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.
Labtron supplies advanced models of Table Top Spectrophotometers which are used in pharmaceuticals, operating within a UV-Vis range of 190–1100 nm. This allows detection of most organic compounds and excipients. For enhanced accuracy, choose a spectrophotometer with a dual-beam configuration and a bandwidth of 1 nm or better. Instruments with deuterium and tungsten-halogen lamps are typically used. A high signal-to-noise ratio is crucial for low concentration detection. Built-in IQ/OQ/PQ protocols are also essential. Always verify the spectral resolution and baseline stability before purchase.
Labtron’s Table Top Spectrophotometer measurement speed varies depending on the complexity of the test and the model’s capabilities, but most modern spectrophotometers provide fast results. Typical measurement times range from a few seconds to one minute per sample. Advanced spectrophotometers designed for high-throughput environments may offer even faster processing speeds. For more complex tests, like spectral scanning or kinetic analysis, the measurement time may be longer, but these models can still perform these tasks more quickly than traditional systems. The fast measurement capabilities ensure that laboratories can handle large volumes of samples efficiently while maintaining accuracy.
Labtron supplies advanced Table Top Spectrophotometers. Stray light is unwanted light that reaches the detector, distorting absorbance values, especially at high absorbance levels. It can originate from reflections, diffraction imperfections, or scattered light within the monochromator. This leads to non-linearity in Beer-Lambert law, limiting the dynamic range. Stray light can be minimized by using high-quality optics, baffles, and interference filters. Regularly check stray light levels using cut-off filters like sodium nitrite or potassium chloride. Dual-beam systems typically offer better stray light rejection.
Labtron’s Table top spectrophotometer play a critical role in drug development by enabling accurate analysis of the chemical composition and concentration of pharmaceutical compounds. They are used for routine quality control of raw materials, intermediates, and finished products. These instruments are also employed in stability studies to monitor the degradation of drugs over time under various conditions. In addition, spectrophotometers are used to assess the purity of active pharmaceutical ingredients (APIs) and to conduct in-vitro dissolution testing. With their high precision, they help ensure that drugs meet regulatory standards.
Labtron manufactures Table Top Spectrophotometer with multiple light sources. Light source in a spectrophotometer is critical to ensuring accurate and consistent results. Fluctuations in light intensity can lead to measurement errors, especially in sensitive applications like low concentration analysis. Stable light sources, such as deuterium lamps for the UV range and tungsten lamps for the visible range, provide more reliable and reproducible results. Our spectrophotometers often use advanced light source calibration systems to compensate for drift over time. A stable light source improves precision by minimizing the need for frequent recalibration, thus enhancing long-term performance and reliability.
Labtron’s Table Top Spectrophotometers feature multi-wavelength capabilities allow users to simultaneously measure multiple wavelengths, enabling complex, multi-component analysis. This is particularly useful in applications where multiple compounds are present in a sample, and their absorption peaks overlap. By measuring several wavelengths at once, the instrument can distinguish between different substances and accurately quantify their concentrations. Multi-wavelength analysis also speeds up the testing process, as it eliminates the need for multiple scans. Additionally, these systems can be programmed to measure specific wavelengths of interest for particular applications, further enhancing their versatility in research and quality control.
Post your question?
Our experts are here to help!
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom