| Illumination system | d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Sensor | Dual light path sensor array |
| Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
| Wavelength range | 400-700 nm |
| Wavelength interval | 10 nm |
| Half spectral width | 5 nm |
| Reflectivity range & resolution | 0 to 200%, 0.01% |
| Observation Angle | 2°/10° |
| Measurement time interval | 0.5 s |
| Measurement time | 2 s |
| Measuring aperture | 25.5*10 mm (cuvette support) |
| Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell Mi, CMYK |
| Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555color classification |
| Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, staining fastness, color fastness, APHA, Astm color, ISO illuminance, saybolt |
| Repeatability | Transmittance: standard deviation within 0.08% color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03 |
| Work temperature range | 0-45°C, relative humidity 80% or below (at 35°C), no condensation |
| Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
| Data being displayed | Samples color values,color difference values/graph,pass/fail results,color error tendency,color value simulation, color difference values, display measurement area,history data color simulation,manual input standard sample, generate measurement report |
| Interface | USB |
| Data storage | Mass storage (on PC) |
| Light source longevity | 5 years, 1.5 million tests |
| Dimension (L*W*H) | 475 × 340 × 150 mm |
| Weight | 7 kg |
Transmittance spectrophotometer is used in the measurement of range of liquids and solvents like resins, solvents, oils etc. to be used in food, chemical, textile, life science industries.
| Accessories No. | Name |
| 1 | Power cord |
| 2 | USB cable |
| 3 | Driving software |
| 4 | Color QC software |
| 5 | Black and white calibration tile |
Glass Cuvette (40x10mm)
Download catalog for
Table top spectrophotometer LTS-A13 Catalog
Available Range :
Table top spectrophotometer LTS-A13 : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement Table top spectrophotometer LTS-A10 : d/8 (Diffused lighting, 8° observation angle)Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.


.webp)





Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608