Table Top Spectrophotometer LTS-B17 offers the data storage capacity of 2,000 standard records and upto 20,000 of sample records, ensuring easy access of large datasets. It supports barcode scanning, allowing the spectrophotometer to quickly identify and track samples. The spectrophotometer has UV measurement option, providing precise UV analysis for testing materials. Our table top spectrophotometer features integrated camera positioning, providing easy adjustments for accurate results.

Table Top Spectrophotometer LTS-B17
Table Top Spectrophotometer LTS-B17
Table Top Spectrophotometer LTS-B17
Table Top Spectrophotometer LTS-B17
Request Quote
Storage Capacity Standard: 2000 Pcs
Sample: 20000 Pcs
Wavelength Pitch 10nm
Semiband Width 5nm
Sensor 256 Images Element Double Array CMOS Image Sensor
Reflectance Range 0 to 200 %
Measurement Time 2.4 s
Measurement Aperature Reflective : Φ30mm / Φ25.4mm , Φ 10mm / Φ 8mm, Φ 6mm / Φ4mm
Transmissive : Φ30mm / Φ 25.4mm
Viewing Angle 2° and 10°
Illuminant 360 to 780 nm Xenon lamp, 400 nm cut-off
Optical Geometry Reflect : D/8
Transmission: D/0
Repeatability Standard deviation 0.07 %
Standard deviation ΔE × ab 0.015
Standard deviation 0.07 %
Standard deviation ΔE × ab 0.018
Illuminants D 65, A , C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, DLF, TL83, TL84, TPL5, U30.
Color Spaces CIE LAB, XYZ, Yxy, LCh, CIE LUV
Musell, s-RGB Hunter Lab, Bxy, DIN Lab99
Color Difference ΔE ab, ΔE uv, ΔE 94, ΔE cmc (2:1), ΔE ×cmc (1:1)
ΔE 00, DIN Δ E99, ΔE(Hunter)
Calorimetric Index WI( ASTM E313, CIE/ ISO, AATCC, Hunter)
YI(ASTM D1925, ASTM 313)
MI (Metamerism Index )
Staining Fastness, Color Fastness, Color Strength, Opacity, 8˚
Glossiness , Gardner Index, Haze , APHA / Pt – Co Index, 555
Index, Haze (ASTM D1003)
Saybolt , Color code (ASTM D1500)
Inter- Instrument Error Φ 25.4 mm / SCI ΔE × ab 0.12
Sphere Size Φ154mm
Power Consumption DC 24 V, 3A
Dimensions ( L× W× H) 370 × 300 × 200 mm
Weight 9.6 kg
  • Low Instrument Error

  • High Resolution Optics

  • Color Stability Monitoring

  • Adjustable Light Source

  • Advanced Data Software

Table Top Spectrophotometer LTS-B17 is a benchtop device used in research and development sector where high accuracy color analysis is essential. It is widely applied in the automobile and electronics industries for quality control of components and surfaces.

Accessories Name

Quantity

Power Adapter

1

USB Cable

1

Software Fixing Frame

1

Transmission Blackboard

1

Sample Holder

1

Aperature 

1

Standard Calibration Board

1

Black Calibration Board

1

Models of Table Top Spectrophotometer

Labtron Table Top Spectrophotometer features ETC technology ensuring real-time calibration for precise results. They support multiple measurement apertures, including options for small, medium, and large sample sizes. They also have specialized configurations for liquids and reflective materials. Their high-capacity rechargeable batteries provide long-lasting performance. Our Table Top Spectrophotometer offer a wide range of color spaces and color difference formulas catering to diverse application needs.

Table top spectrophotometer LTS-A11

Table top spectrophotometer LTS-A11

  • Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
Table Top Spectrophotometer LTS-A16

Table Top Spectrophotometer LTS-A16

  • Wavelength Range : 360 nm to 780 nm
  • Wavelength Pitch : 10 nm
  • Sensor : Silicon Photodiode Array
  • Grating Method : Concave Grating
Table Top Spectrophotometer LTS-B12

Table Top Spectrophotometer LTS-B12

  • Measuring Time : 2s
  • Wavelength Range : 360-780nm
  • Wavelength Pitch : 10nm
  • Sphere Size : Φ154mm
Table top spectrophotometer LTS-A13
Table top spectrophotometer LTS-A13
  • Illumination system : d/0 (Diffused lighting, 0° observation viewing), SCS optical engine (light splitting and integration system), ETC (every time calibration technology), SCI (specular reflection included)/ SCE (specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 40 mm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
Table Top Spectrophotometer LTS-B15
Table Top Spectrophotometer LTS-B15
  • Wavelength Pitch : 10nm
  • Sphere Size : Φ154mm
  • Semiband Width : 5nm
  • Sensor : 256 Images Element Double Array CMOS Image Sensor
Table top spectrophotometer LTS-A12

Table top spectrophotometer LTS-A12

  • Illumination system : d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
  • Size of integrated sphere : 15.2 cm, alvan diffused reflection surface coating
  • Illumination light source : CLED
  • Sensor : Dual light path sensor array
Table Top Spectrophotometer LTS-B14

Table Top Spectrophotometer LTS-B14

  • Reflectance Range : 0 to 200%
  • Sphere Size : Φ154mm
  • Semiband Width : 5nm
  • Sensor : 256 Images Element Double Array CMOS Image Sensor
Table Top Spectrophotometer LTS-B11

Table Top Spectrophotometer LTS-B11

  • Sphere Size : Φ154mm
  • Wavelength Range : 360 to 780 nm
  • Sensor : 256 Images Element Double Arrays
  • Wavelength Pitch : 10nm

Table Top Spectrophotometer LTS-B17 FAQ's
  • Labtron’s Table Top Spectrophotometer have motorized stages which enables automatic positioning, averaging, and multi-spot analysis of large or patterned samples. This reduces human error and increases repeatability. Automated sample movement ensures consistent geometry and improves throughput in batch testing. It's particularly useful for structured surfaces like leather, fabric, or embossed films. Some stages include X-Y-Z control to analyze thickness-dependent reflectance changes. Coupled with imaging integration, motorized stages enhance visual and spectral correlation. Advanced units allow barcode-triggered measurements and batch-mode operation. This automation reduces operator training requirements and standardizes production QC. It also integrates well with robotic arms in smart labs.

  • Labtron manufacture advanced Table Top Spectrophotometer, the translucent materials scatter light within their structure, causing variable readings based on thickness, background, or sample positioning. Tabletop spectrophotometers need specialized transmission fixtures or compensation algorithms to measure them accurately. Double-beam or dual-optic designs help isolate the true spectral transmittance. Placing a standardized backing or using an opaque white/black reference improves repeatability. Some instruments allow averaged directional reflectance to estimate scattering behavior. It's essential in evaluating films, frosted plastics, and cosmetic packaging. Translucent color QC requires careful sample prep and controlled ambient conditions. Consistent methodology ensures reliable results across production batches.

  • Labtron supplies Table Top Spectrophotometer with high accuracy. Wavelength accuracy is a critical factor in ensuring precise spectral analysis, as even small deviations in wavelength measurement can lead to significant errors in color data. Spectrophotometers with high wavelength accuracy ensure that the light passed through the sample is accurately measured at the desired wavelengths, which is essential for obtaining correct colorimetric values. In industries that rely on precise color matching, such as coatings or pharmaceuticals, even a minor wavelength shift can lead to color misrepresentation or poor product quality. Instruments with advanced wavelength calibration and precision optics minimize these errors, ensuring consistent and reliable results across various sample types.

  • Yes, advanced Table Top Spectrophotometers are designed to measure irregularly shaped or textured samples. They feature adjustable apertures, rotating sample stages, and specialized positioning fixtures that ensure accurate measurements regardless of sample shape. The instrument compensates for light scattering and other optical distortions caused by uneven surfaces, ensuring consistent results. This is especially useful for applications involving materials like textiles, leather, or rough industrial surfaces, which have complex topographies. Some models include automated sample alignment systems, further reducing the risk of measurement errors. The flexibility makes these spectrophotometers suitable for a variety of industries with complex sample shapes.

  • Yes, Table Top Spectrophotometers feature built-in memory that allows users to store multiple color standards, test results, and calibration data. This functionality is useful for industries that require frequent color comparisons, such as automotive, textiles, or packaging. With stored color standards, users can quickly access and compare new samples to ensure consistency across different production batches. The ability to store a variety of color standards helps streamline quality control and facilitates quicker decision-making. Additionally, this feature allows for easy access to historical data for trend analysis and product improvement. It reduces the need for manual tracking and speeds up the inspection process.

  • Labtron’s Table Top Spectrophotometer has advanced firmware, playing a crucial role in optimizing measurement algorithms, controlling the light source, and handling calibration processes. Advanced firmware enhances measurement accuracy by automatically adjusting for environmental variables like temperature and humidity, and it also allows for real-time correction of any calibration drift. Firmware improvements often include enhanced color difference formulas, customizable measurement protocols, and quicker data processing, resulting in more efficient operation. Additionally, firmware upgrades can add new functionalities, such as support for new color spaces or measurement standards, and improve the user interface, making the spectrophotometer more intuitive to use.

Post your question?

Our experts are here to help!

Table Top Spectrophotometer:
Table top spectrophotometer LTS-A11, Table Top Spectrophotometer LTS-A16, Table Top Spectrophotometer LTS-B12, Table top spectrophotometer LTS-A13, Table Top Spectrophotometer LTS-B15, Table top spectrophotometer LTS-A12, Table Top Spectrophotometer LTS-B14, Table Top Spectrophotometer LTS-B11, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.