| Temperature Range | 10°C to 100°C |
| Detection Method | Semi-automatic |
| Processing Capacity | 3 / batch |
| Temperature Resolution | 0.1°C |
| Heat Range | (0.1 to10.0) °C / min |
| Accuracy | ± 0.3°C |
| Repeatability | Heating Rate 0.1°C at 0.1°C / min |
| Video Function | Take pictures and Videos |
| Video Playback | Yes |
| User Management | 8 |
| Results Saving | 400 |
| Data Storage | 16 GB |
| Display Mode | TFT HD Color Screen |
| Data Interface | USB RS232 SD Card RJ 45 |
| Open Capillary Size | I.D. 1.0 mm, O.D. 1.4 mm double openings |
| Power Supply | 110 to 220 V 50 Hz / 60 Hz |
| Power Consumption | 120 W |
High-Precision Temperature Sensors
Digital Calibration Functions
Rapid Heating Rates
Overheat Protection Mode
Integrated Cooling Fan
Melting Point Apparatus LDMP-A23 determines the melting point of chemical substances with visual clarity. It is widely used in quality control laboratories, forensic sciences and material sciences for quality control and studying thermal properties.
Download catalog for
Melting Point Apparatus LDMP-A23 Catalog
Available Range :
Melting Point Apparatus LDMP-A31 : 10°C to - 400°C Melting Point Apparatus LDMP-A23 : 10°C to 100°C Melting Point Apparatus LDMP-A20 : Room temperature to 350 ℃ Melting Point Apparatus LDMP-A21 : Room temperature to 360℃ Melting Point Apparatus LDMP-A33 : RT to -400°C Melting Point Apparatus LDMP-A34 : RT to -420°C Melting Point Apparatus LDMP-A12 : RT to 320°C Melting Point Apparatus LDMP-A22 : RT to 350°C Melting Point Apparatus LDMP-A13 : RT to 400°CLabtron Touch Screen Melting Point Apparatus offers temperature upto 420℃ with touch display at which solid turns into liquid. They feature heating block that ensures uniform thermal distribution. Their construction includes capillary tube that holds sample in place for accurate determination. They include optical system to clearly observe transition of sample. Our Touch Screen Melting Point Apparatus is suitable for purity testing, compound characterization, environmental analysis and forensic analysis.








Labtron supplies premium melting point apparatus LDMP-A23. Accurate melting point determination starts with properly prepared samples. Use dry, finely powdered solids loaded into a capillary tube to about 2–3 mm depth; crushing larger crystals helps ensure uniform packing and thermal contact. Avoid contamination by using clean tubes and drying hygroscopic materials beforehand, as residual solvents can lower and widen the melting range. Gentle tapping or centrifugation removes air gaps, ensuring consistent heat transfer. Proper prep improves repeatability and accuracy, reducing outliers and misleading readings.
Labtron supplies premium melting point apparatus LDMP-A23. Set the initial “plateau” about 15–20?°C below the expected melting point for preheating, then switch to a slow ramp (1–5 °C/min) as melting begins. Fast initial heating saves time while the slower rate near melting delivers sharper transitions and narrower ranges. Most pharmacopeia and software-guided devices recommend a consistent 1?°C/min ramp through the melting interval. Following these settings minimizes superheating and thermal lag, ensuring accurate and comparable results.
Labtron supplies premium melting point apparatus LDMP-A23.Calibration involves measuring certified reference standards-like benzoic acid or naphthalene-at multiple points across the instrument's range. Adjust any offsets if measured values fall outside tolerance limits, then verify with different references to confirm accuracy. Many systems support up to five-point calibration and gener ate performance certificates for regulatory compliance. Routine checks before experiments help detect drift and maintain confidence in your data.
Labtron supplies premium melting point apparatus LDMP-A23. Deviations from expected values may arise from impurities (which lower and broaden the range), overheating (from too-fast heating), and poor capillary packing. Calibration errors or a failing temperature sensor can also cause anomalies in readings. Use two samples-one known and one unknown-to isolate whether the problem is the sample or the instrument. Troubleshooting by reviewing prep, settings, and system performance ensures reliable outcomes.
Labtron’s advanced melting point apparatus LDMP-A23 instruments include built-in cameras that record videos or capture images of the melting tube. This allows software to automatically detect the start and end of melting, reducing operator subjectivity and improving precision. Video playback on a touchscreen offers visual confirmation and auditability. Multichannel systems can simultaneously analyze several samples. These features support compliance requirements like 21 CFR 11 with timestamped data and user logs, and streamline workflows in high-throughput or regulated labs.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608