| Productivity Rate | 30 L/h |
| Water Temperature | 5 ℃ to 40 ℃ |
| Water Pressure | 0.1 to 0.4 MPa |
| Class I Resistivity (25 ℃) | 18.2 MΩ.cm |
| Class I Conductivity (25 ℃) | 0.055 us/cm |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Class I Particulate Matter | < 1 pc/ml |
| Manual Dispense Flow Rate | 1.5 to 2.0 L/min |
| Automatic Dispense Volume | 100-60000 ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 380 × 380 × 595 mm |
| External Dimension (Water Tank) | 315 × 525 × 570 mm |
| Net Weight (Main Units) | 34 Kg |
| Net Weight (Water Tank) | 7 Kg |
Tap Water Feed
Smart Dispensing Handle
Advanced Design & Construction
Innovative Storage Solution
Water Quality Assurance
Our Ultrapure Water System LUWS-C11 provides nuclease-free water essential for molecular biology applications including PCR, DNA sequencing, and electrophoresis, preventing sample degradation while ensuring precise, reliable results.
Accessories | Quantity | Unit |
Pretreatment cartridge with chip recognition function | 1 | Piece |
High pressure pump | 1 | Piece |
Reverse osmosis module (casting + membrane) | 1 | Piece |
Dual wavelength UV lamp with detection function | 1 | Piece |
Purification cartridge with chip recognition function | 1 | Piece |
TOC online monitoring module | 1 | Piece |
Ultra-purification cartridge with chip recognition function | 1 | Piece |
Microfilter | 1 | Piece |
Point of use filter (0.22 µm) | 1 | Piece |
30 liters multifunctional water tank | 1 | Piece |
Air vent for water tank | 1 | Piece |
24V UV lamp for water tank | 1 | Piece |
Water leakage detection sensor | 1 | Piece |
Remote water dispenser with display | 1 | Piece |
Accessories | Quantity | Unit |
Pretreatment module with identification chip | 1 | Piece |
Purification cartridge dual column | 1 | Piece |
Ultra-purification cartridge dual column | 1 | Piece |
Ultra-purification cartridge single column | 1 | Piece |
Micro filter | 1 | Piece |
Point-of-use filter (0.22 µm) | 1 | Piece |
Point-of-use filter (General) | 1 | Piece |
Bio filter | 1 | Piece |
Strengthened pretreatment module | 1 | Piece |
Strengthened pretreatment cartridge column PP cotton | 1 | Piece |
Strengthened pretreatment cartridge column active carbon | 1 | Piece |
Dual wavelength UV lamp tube | 1 | Piece |
10 Gallon pressure water tank | 1 | Piece |
100G Reverse osmosis module | 1 | Piece |
200G Reverse osmosis module | 1 | Piece |
254/185 nm dual wavelength UV lamp | 1 | Piece |
24 V UV sterilization lamp for water tank | 1 | Piece |
Download catalog for
Ultrapure Water System LUWS-C11 Catalog
Labtron Ultrapure Water System feature advanced multi-stage filtration processes, ensuringthe removal of all contaminants. They are designed for efficient water delivery and high flowrates. Our system are energy efficient, providing consistent reliability. They are equippedwith a touch-screen panel and real-time alerts for easy operation. They produce Type Iultrapure water, ideal for critical applications such as molecular biology, cell culture, andanalytical chemistry.








The lifespan of an Ultrapure Water System LUWS-C11 typically ranges from 5 to 10 years depending on usage, maintenance, and water quality. Regular filter and membrane replacements such as RO membranes every 1-2 years are crucial to prevent clogging and maintain efficiency. Conducting routine sanitization cycles helps minimize bacterial growth while monitoring resistivity and TOC levels ensures consistent purity. Avoiding feed water with high particulate or organic loads reduces wear on components. Proper storage of purified water using UV-sterilized tanks prevents recontamination.
Yes, Ultrapure Water System LUWS-C11 offer modular customization to match lab requirements such as adding extra purification stages like dual RO or additional UV oxidation for stricter TOC control. Some systems allow adjustable flow rates from 1 to 2 L/min for high-demand applications like HPLC. Integration with lab networks via Ethernet or Wi-Fi enables remote monitoring and data logging. For specialized needs such as endotoxin-free water for cell culture, post-treatment cartridges like ultrafiltration can be added. Manufacturers may also provide industry-specific configurations such as GMP-compliant systems for pharmaceuticals or low-metal systems for trace analysis.
Advanced systems use multi-stage pretreatment such as sediment filters and carbon blocks to stabilize feed water before purification. Real-time sensors detect changes in TOC, resistivity, or particle levels triggering automatic adjustments like flushing cycles. For hard water, scale-inhibiting technology prevents mineral buildup in RO membranes. Some models include dual-input options such as tap water plus pre-treated water to bypass poor-quality feed. Alerts and shutdown protocols activate if contaminants exceed thresholds protecting the system. Regular maintenance logs help track feed water trends and pre-empt issues.
Modern systems prioritize safety with leak-detection sensors that shut off water flow during breaches. Water-electricity separation prevents short circuits while UV sterilization eliminates microbial risks in stored water. Touchscreen interfaces with password protection restrict unauthorized access to settings. Auto-shutoff valves activate during maintenance or power failures. For labs handling hazardous materials, chemical-resistant materials like PTFE tubing prevent corrosion. Some systems are CE/UL-certified for electrical safety and ISO 13485-compliant for medical applications.
Ultrapure water exceeds distilled or DI water in purity with resistivity of at least 18.2 M?·cm compared to DI’s 1 M?·cm and TOC below 5 ppb versus distilled’s 500 ppb. Distillation removes ions but not volatile organics while DI lacks bacteria and endotoxin removal. Ultrapure systems combine RO, EDI, UV, and ultrafiltration to eliminate all contaminants including nanoparticles and nucleases. Distilled water is sufficient for rinsing glassware but ultrapure is mandatory for sensitive assays like mass spectrometry. Storage is also critical as distilled water degrades quickly whereas ultrapure systems often include recirculation loops to preserve quality.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom