| RO Production Rate | 15 L/h |
| Source | Tap water |
| Conductivity | < 2000 us/cm |
| Hardness | < 450 ppm as CaCO3 |
| Water Temperature | 5 ℃ to 40 ℃ |
| Water Pressure | 0.05 to 0.5 MPa |
| Class III Ionic Rejection | > 95% |
| Class III Bacteria Rejection | > 99% |
| Class I Resistivity (25 ºC) | 18.2 MΩ.cm |
| Class I Water Conductivity (25 ºC) | 0.055 us/cm |
| Class I Particulate Matter | < 1 pc/ml |
| Class I Water Total Organic Carbon Level | 1 to 5 ppb |
| Manual Dispense Flow Rate | 1.2 to 1.5 L/min |
| Automatic Dispense Volume | 100 to 60000 ml |
| Electrical Voltage | 110 V/220 V±10% |
| Electrical Frequency | 50 HZ/60 HZ |
| External Dimension (Main Units) | 315 × 525 × 570 mm |
| Packaging Dimensions | 610 × 525 × 745mm |
| Net Weight (Main Units) | 32 kg |
PIN-Protected Settings
Dual Cartridge System
Leak-Proof Design
Quick-Connect Cartridge Replacement
Customized Pre-Filtration Option
Our Ultrapure Water System supports HPLC, IC, GC, molecular biology, PCR, DNA/RNA analysis, cell culture, protein purification, diagnostics, and reagent preparation with ultra-low TOC, ensuring reliable, contamination-free results.
Accessories | Quantity | Unit |
Pretreatment cartridge | 1 | Piece |
High pressure pump | 1 | Piece |
Reverse osmosis module | 1 | Piece |
254/185 nm dual wavelength UV lamp | 1 | Piece |
Purification cartridge | 1 | Piece |
Microfilter | 1 | Piece |
Point of use filter (0.22 µm) | 1 | Piece |
Internal 6.0L PE water tank | 1 | Piece |
Water leakage detection sensor | 1 | Piece |
Accessories | Quantity | Unit |
Pretreatment module with identification chip | 1 | Piece |
Purification cartridge dual column | 1 | Piece |
Ultra-purification cartridge dual column | 1 | Piece |
Ultra-purification cartridge single column | 1 | Piece |
Micro filter (General) | 1 | Piece |
Point-of-use filter (0.22 µm) | 1 | Piece |
Point-of-use filter (General) | 1 | Piece |
Point-of-use bio filter | 1 | Piece |
Strengthened pretreatment module | 1 | Piece |
Strengthened pretreatment cartridge column PP cotton | 1 | Piece |
Strengthened pretreatment cartridge column active carbon | 1 | Piece |
30L multifunctional water tank with integrated UV lamp & air vent | 1 | Piece |
60L multifunctional water tank integrated UV lamp & air vent | 1 | Piece |
100G Reverse osmosis module | 1 | Piece |
200G Reverse osmosis module | 1 | Piece |
254/185 nm dual wavelength UV lamp | 1 | Piece |
24 V UV sterilization lamp for water tank | 1 | Piece |
Download catalog for
Ultrapure Water System LUWS-E13 Catalog
Labtron Ultrapure Water System feature advanced multi-stage filtration processes, ensuringthe removal of all contaminants. They are designed for efficient water delivery and high flowrates. Our system are energy efficient, providing consistent reliability. They are equippedwith a touch-screen panel and real-time alerts for easy operation. They produce Type Iultrapure water, ideal for critical applications such as molecular biology, cell culture, andanalytical chemistry.








Yes, Labtron’s Ultrapure Water System LUWS-E13 is structurally designed for wall mounting, making it ideal for compact and efficient laboratory installations.
Yes, Labtron’s Ultrapure Water System LUWS-E13 complies with IEC 61010-1 safety standards and the EMC Directive 2014/30/EU, ensuring reliable operational safety in laboratory environments.
Yes, Labtron’s Ultrapure Water System LUWS-E13 is equipped with a water leakage sensor that automatically shuts off the feed water in case of floor-level leakage detection.
Yes, Labtron’s Ultrapure Water System LUWS-E13 features an internal 6.5-liter tank with three programmable water levels to control production based on user-defined settings.
Yes, Labtron’s Ultrapure Water System LUWS-E13 uses a point-of-use filter that serves as an air block mechanism, preventing air intrusion into ultrapure water lines.
Yes, Labtron’s Ultrapure Water System LUWS-E13 is supplied with a full set of pre-installed consumables, including cartridges and reagents. User can connect the power and water for direct usage.
Accurate solution preparation requires consistent water purity, free of contaminants that may alter solute concentration or pH. The Ultrapure Water System LUWS-E13 provides stable water quality with continuously monitored parameters such as resistivity and TOC. Its integrated purification stages ensure low ionic and organic content, making it ideal for standard and volumetric solution preparation. Consistency in water quality minimizes variation across experimental batches. The system also reduces the risk of introducing background interference in analytical techniques like titration, spectrophotometry, or chromatography. This level of purity is vital for reproducible results and proper calibration.
Yes, the ultrapure water produced by Ultrapure Water System LUWS-E13 is well-suited for trace metal analysis and elemental detection techniques like AAS, ICP-OES, or ICP-MS. These applications require extremely low background contamination, especially from trace metals or organics. The system’s multi-stage purification process, including advanced ion exchange and membrane technologies ensures the removal of interfering substances. Its high-purity output supports sensitive detection at parts-per-trillion levels. Additionally, closed-circuit design minimizes recontamination during dispensing.
Consistency in reagent and standard solution preparation relies heavily on water quality remaining stable over time. The Ultrapure Water System LUWS-E13 includes real-time monitoring and alarms to notify users of any deviations in water parameters. Automated flushing and self-cleaning mechanisms help preserve performance and extend component life. High-capacity cartridges reduce the frequency of maintenance and reduce variability in water output. This results in uniform water quality that supports reliable preparation from one batch to the next. Consistent purity is essential for calibration standards, buffer preparation, and reproducible lab results.
Ultrapure water acts as a baseline solvent and rinse medium in many lab workflows, making its purity directly tied to contamination control. Using substandard water can introduce particles or biological agents that compromise experimental integrity. Genius-Lite minimizes this risk by eliminating bacteria, organics, ions, and particulates through a layered purification approach. It supports clean rinsing of labware and tools, preventing residue buildup or cross-contamination between experiments. For sensitive workflows like nucleic acid handling or protein purification, such high purity is essential. This results in higher success rates and reproducible outcomes.
Ultrapure water ensures that there are no interfering ions or buffer residues that could alter the pH of prepared solutions. For pH-sensitive reagents or buffers, even small traces of acid/base contaminants can shift the pH value significantly. The Genius-Lite system delivers consistent high-purity water with minimal ionic content, providing a stable base for pH calibration and formulation. This allows lab technicians to achieve the desired pH without compensating for unknown impurities. Additionally, the system’s real-time conductivity monitoring helps verify that water quality is suitable for such precise preparations. Accurate pH formulation is critical for enzymatic reactions, cell culture buffers, and analytical reagents.
Post your question?
Our experts are here to help!
Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608