Ultrapure Water System LUWS-E12 offers a TOC level between 1 to 5 ppb, ensuring low organic contamination. It features an LCD that displays real-time temperature, conductivity, system status, and consumables life. Built-in PP cotton and activated carbon with descaling agents extend RO membrane life. The system incorporates DOW membrane ensuring high recovery and long lifespan. Our Ultrapure Water System is ideal for producing ultrapure water with ultra-low organics required for HPLC, IC, GC, and GC/MS applications.

Request Quote
RO Production Rate 15 L/h
Source Tap water
Conductivity < 2000 us/cm
Hardness < 450 ppm as CaCO3
Water Temperature 5 ℃ to 40 ℃
Water Pressure 0.05 to 0.5 MPa
Class III Ionic Rejection > 95%
Class III Bacteria Rejection > 99%
Class I Resistivity (25 ºC) 18.2 MΩ.cm
Class I Water Conductivity (25 ºC) 0.055 us/cm
Class I Particulate Matter < 1 pc/ml
Class I Water Total Organic Carbon Level 1 to 5 ppb
Manual Dispense Flow Rate 1.2 to 1.5 L/min
Automatic Dispense Volume 100 to 60000 ml
Electrical Voltage 110 V/220 V±10%
Electrical Frequency 50 HZ/60 HZ
Dimension 315 × 525× 570 mm
Packaging Dimensions (W ×H ×D) 610 × 525 × 745mm
Net Weight 20 kg
Gross Weight 35 kg
  • Smart Operation System

  • Enhanced Pretreatment Design

  • Superior Ion Exchange

  • Space-Saving Design

  • Automatic Dispensing Mode

Our Ultrapure Water System supports HPLC, IC, GC, molecular biology, PCR, DNA/RNA analysis, cell culture, protein purification, diagnostics, and reagent preparation with ultra-low TOC, ensuring reliable, contamination-free results. 

Accessories

Quantity

Unit

Pretreatment cartridge 

1

Piece

High pressure pump

1

Piece

Reverse osmosis module 

1

Piece

254/185 nm dual wavelength UV lamp

1

Piece

Purification cartridge

1

Piece

Microfilter

1

Piece

Point of use filter (0.22 µm)

1

Piece

Internal 6.0L PE water tank

1

Piece

Water leakage detection sensor

1

Piece

Accessories 

Quantity

Unit

Pretreatment module with identification chip

1

Piece

Purification cartridge dual column

1

Piece

Ultra-purification cartridge dual column

1

Piece

Ultra-purification cartridge single column

1

Piece

Micro filter (General)

1

Piece

Point-of-use filter (0.22 µm)

1

Piece

Point-of-use filter (General)

1

Piece

Point-of-use bio filter 

1

Piece

Strengthened pretreatment module

1

Piece

Strengthened pretreatment cartridge column PP cotton

1

Piece

Strengthened pretreatment cartridge column active carbon

1

Piece

30L multifunctional water tank with integrated UV lamp & air vent   

1

Piece

60L multifunctional water tank integrated UV lamp & air vent 

1

Piece

100G Reverse osmosis module

1

Piece

200G Reverse osmosis module

1

Piece

254/185 nm dual wavelength UV lamp

1

Piece

24 V UV sterilization lamp for water tank

1

Piece

Ultrapure Water System LUWS-E12 | RO Production Rate: 15 L/h | Manual Dispense Flow Rate: 1.2 to 1.5 L/min
Ultrapure Water System LUWS-E12 | Smart Operation System | Enhanced Pretreatment Design

Models of Ultrapure Water system

Labtron Ultrapure Water System feature advanced multi-stage filtration processes, ensuringthe removal of all contaminants. They are designed for efficient water delivery and high flowrates. Our system are energy efficient, providing consistent reliability. They are equippedwith a touch-screen panel and real-time alerts for easy operation. They produce Type Iultrapure water, ideal for critical applications such as molecular biology, cell culture, andanalytical chemistry.

Ultrapure Water System LUWS-A15

Ultrapure Water System LUWS-A15

  • Water Yield : 20 L/H at 25 ℃
  • Resistivity : 15 to 18.2 MΩ.cm
  • Heavy Metal Ion : Less than 0.1 ppb
  • Bacteria : Less than 1 CFU/ml
Ultrapure Water System LUWS-E21

Ultrapure Water System LUWS-E21

  • Source : Tap water
  • Conductivity : < 2000 us/cm
  • Hardness : < 450 ppm as CaCO3
  • Water Temperature : 5 ℃ to 40 ℃
Ultrapure Water System LUWS-C20

Ultrapure Water System LUWS-C20

  • Source : RO, Distilled, DI water
  • Water Temperature : 5℃ to 40℃
  • Water Pressure : 0.1 to 0.8 MPa
  • Class I Resistivity (25℃) : 18.2 MΩ.cm
Ultrapure Water System LUWS-F10
Ultrapure Water System LUWS-F10
  • Source : Tap Water
  • Conductivity : < 2000 µs/cm
  • Hardness : < 450 ppm as CaCO3
  • Water Temperature : 5 °C to 40 °C
Ultrapure Water System LUWS-C10
Ultrapure Water System LUWS-C10
  • Productivity Rate : 30 L/h
  • Water Temperature : 5 ℃ to 40 ℃
  • Water Pressure : 0.1 to 0.4 MPa
  • Class I Resistivity (25 ℃) : 18.2 MΩ.cm
Ultrapure Water System LUWS-F11

Ultrapure Water System LUWS-F11

  • Source : Tap Water
  • Conductivity : < 2000 µs/cm
  • Hardness : < 450 ppm as CaCO3
  • Water Temperature : 5 °C to 40 °C
Ultrapure Water System LUWS-A12

Ultrapure Water System LUWS-A12

  • Water Output Rate : 30L/Hr
  • Water Flow Rate : 1.5 to 2L/min (with pressure barrel)
  • Water Temperature : 5 to 40°C
  • Inlet Water Pressure : 0.15 to 0.5mpa
Ultrapure Water System LUWS-D12

Ultrapure Water System LUWS-D12

  • Source : Tap water
  • Conductivity : < 2000 us/cm
  • Hardness : < 450 ppm as CaCO3
  • Water Temperature : 5 ℃ to 40 ℃

Ultrapure Water System LUWS-E12 FAQ's
  • Sensitive biological assays such as ELISA, PCR, and cell viability tests demand water free from endotoxins, nucleases, and other biological contaminants. Ultrapure Water System LUWS-E12 includes purification stages that remove these agents, ensuring the water used in reagent preparation does not compromise assay results. High-purity water prevents enzyme degradation and supports accurate reaction kinetics. It also enhances reagent stability and minimizes variability across assay runs. Laboratories working in clinical diagnostics or pharmaceutical R&D benefit from this level of purity. This makes Ultrapure Water System LUWS-E12 a reliable source of water for preparing highly sensitive biochemical reagents.

  • Buffer solutions must be prepared with water that is free from ions, particulates, and microbial contaminants to maintain the desired pH and ionic strength. The Ultrapure Water System LUWS-E12 delivers ultrapure water with minimal conductivity, making it ideal for buffer preparation used in molecular biology. Impurities in water can alter the buffering capacity, affecting experimental consistency and enzymatic reactions. With advanced purification stages, the system prevents the introduction of trace metal ions that could interfere with biological pathways. Real-time monitoring also ensures water quality is consistently within the desired range during buffer preparation. This leads to greater reproducibility and reliability in techniques such as electrophoresis, blotting, and enzyme assays.

  • Yes, ultrapure water is critical for rinsing, calibrating, and maintaining instruments such as HPLC, TOC analyzers, and spectrophotometers. Using Ultrapure Water System LUWS-E12 prevents the buildup of deposits or contaminants that can interfere with readings or damage sensitive components. The water's low conductivity and organic content ensure that instrument baselines remain stable and noise is minimized. Frequent use of high-purity water during cleaning or calibration also extends instrument lifespan. The consistent quality provided by Ultrapure Water System LUWS-E12 makes it a valuable part of any lab’s instrument maintenance routine. This helps maintain data integrity and reduces downtime due to contamination-related faults.

  • Yes, ultrapure water is ideal for microbial media preparation because it avoids introducing foreign ions or inhibitory substances. Ultrapure Water System LUWS-E12, water ensures the media supports accurate microbial growth patterns, free from interference. Some bacteria are sensitive to chlorine, heavy metals, or other trace elements found in tap or insufficiently purified water. The system’s thorough purification eliminates these risks, supporting reproducibility in microbial assays. It also prevents unwanted microbial background, helping in precise colony counts or growth curve analysis. This is crucial in food safety, clinical microbiology, and pharmaceutical applications.

  • User safety is a core design element of the Ultrapure Water System LUWS-E12. It features automated alarms for conductivity deviations, low water pressure, or system malfunctions, ensuring prompt attention before failures occur. The UV lamp and other internal systems are shielded to prevent accidental exposure. A leak detection system helps prevent water damage in sensitive lab areas. Electrical safety components are compliant with international standards, offering protection from voltage surges. Altogether, the system ensures safe, reliable operation in busy laboratory environments.

Post your question?

Our experts are here to help!

Ultrapure Water system:
Ultrapure Water System LUWS-A15, Ultrapure Water System LUWS-E21, Ultrapure Water System LUWS-C20, Ultrapure Water System LUWS-F10, Ultrapure Water System LUWS-C10, Ultrapure Water System LUWS-F11, Ultrapure Water System LUWS-A12, Ultrapure Water System LUWS-D12, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.